共查询到20条相似文献,搜索用时 15 毫秒
1.
Liang Wang Jun Yue Bai Peng Fei Huang Hong Jing Wang Xiao Wei Wu Yu Qing Zhao 《Mikrochimica acta》2007,158(1-2):73-78
The electrochemical behaviors of uric acid (UA) at the penicillamine (Pen) self-assembled monolayers modified gold electrode
(Pen/Au) have been studied. The Pen/Au electrode is demonstrated to promote the electrochemical response of UA by cyclic voltammetry
(CV). The diffusion coefficient D of UA is 6.97 × 10−6 cm2 s−1. In differential pulse voltammetric (DPV) measurements, the Pen/Au electrode can separate the UA and ascorbic acid (AA) oxidation
potentials by about 120 mV and can be used for the selective determination of UA in the presence of AA. The detection limit
was 1 × 10−6 mol L−1. The modified electrode shows excellent sensitivity, good selectivity and antifouling properties. 相似文献
2.
A graphene-modified glassy carbon electrode was fabricated via a drop-casting method, and applied to the electrochemical detection of epinephrine. The capacity of the graphene-modified glassy carbon electrode for the selective detection of epinephrine was confirmed in a sufficient amount of ascorbic acid (2 mmol L(-1)) by cyclic voltammetry. The modified electrode showed an excellent electrocatalytical effect on the oxidation of epinephrine. A pair of well-defined redox waves were observed in voltammograms of epinephrine in a phosphate buffered solution (pH 4.0). The peak potentials of epinephrine remained unchanged, and the oxidation peak currents showed a linear relation versus the epinephrine concentration in the range of 3.85 × 10(-7) - 1.31 × 10(-5) mol L(-1) and 1.31 × 10(-5) - 1.09 × 10(-4) mol L(-1) with a correlation coefficient as follows: i(pa1) = -4.25 × 10(-6) - 1.99c (mol L(-1)), R(1) = 0.9953; i(pa2) = -4.31 × 10(-5) - 0.315c (mol L(-1)), R(2) = 0.9988. Detection limit is estimated to be 8.9 × 10(-8) mol L(-1). Graphene-modified glassy carbon electrode was applied to epinephrine sample analysis, and the results were in good agreement with the standard values. 相似文献
3.
This paper describes the simultaneous determination of ascorbic acid (AA), norepinephrine (NE) and uric acid (UA) using a graphene modified glassy carbon electrode (GME) in pH 4.0 phosphate buffer solution. The electrochemical behaviors of AA, NE and UA at a bare glassy carbon electrode (GCE) and the GME were studied by cyclic voltammetry. Bare GCE failed to resolve the voltammetric signals of AA, NE and UA in a mixture, whereas the GME not only resolved their voltammetric signals, but also exhibited excellent electrocatalytic activity towards their electrochemical oxidation. The oxidation peak currents of AA, NE and UA were linearly proportional to their concentrations over the range of 1.0.0–1000.0, 0.6–45.0 and 1.0–100.0 μM, respectively, and their detection limits were 1.2, 0.10 and 0.60 μM, respectively, The modified electrode is of excellent sensitivity and selectivity, and has been satisfactorily used for the simultaneous determination of AA, NE and UA in their ternary mixture. 相似文献
4.
A voltammetric sensor is presented for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA). It is based on a gold electrode (GE) modified with carboxyl-functionalized graphene (CFG) and silver nanocube functionalized DA nanospheres (AgNC@PDA-NS). The AgNC@PDA-NS nanocomposite was characterized by scanning electron microscopy and UV-Vis spectroscopy. The electrochemical behavior of the modified electrode was evaluated by electrochemical impedance spectroscopy, cyclic voltammetry and differential pulse voltammetry. The modified electrode displays good electrocatalytic activity towards DA (typically at 0.14 V vs. Ag/AgCl) and UA (typically at 0.29 V vs. Ag/AgCl) even in the presence of ascorbic acid. Response to DA is linear in the concentration range of 2.5 to 130 μM with a detection limit of 0.25 μM. Response to UA is linear in the concentration range of 10 to 130 μM with a detection limit of 1.9 μM. In addition, the sensitivity for DA and UA is 0.538 and 0.156 μA μM?1 cm?2, respectively. The modified electrode also displays good stability, selectivity and reproducibility. 相似文献
5.
The graphene nanopowder for electro-catalytic oxidation of dopamine and uric acid in the presence of ascorbic acid has been investigated by cyclic voltammetry,linear polarization and chronoamperometry.The graphene nanopowder modified electrode was prepared using the drop coating method,which displayed excellent electrocatalytic activity towards the oxidation of dopamine and uric acid compared with the bare glassy carbon electrode in phosphate buffer solution at pH=7.0.Linear responses for dopamine and uric acid were obtained in the ranges of3.3μmol/L to 249.1μmol/L and 6.7μmol/L to 386.3μmol/L with detection limits of 1.5μmol/L and 2.7μmol/L(S/N=3),respectively.The response time was less than 2 s in case of dopamine and 3 s in case of uric acid,respectively.The results demonstrated that the graphene nanopowder had potential for detecting dopamine and uric acid. 相似文献
6.
The present work reports a quercetin-modified wax-impregnated graphite electrode (Qu/WGE) prepared through an electrochemical oxidation procedure in quercetin-containing phosphate buffer solution (PBS), for the purpose of detecting uric acid (UA) in the presence of ascorbic acid (AA). During modification quercetin was oxidized to the corresponding quinonic structure, and in the blank buffer solution the electrodeposited film exhibits a voltammetric response anticipated for the surface-immobilized quercetin. Retarding effect of the film towards the reaction of anionic species was found; therefore the pH of sample solutions was selected to ensure the analyte in molecular form. At suitable pHs the Qu/WGE shows excellent electrocatalytic effect towards the oxidation of both AA and UA, and separates the voltammetric signal of UA from AA by about 280 mV, allowing simultaneous detection of these two species. A linear relation between the peak current and concentration was obtained for UA in the range of 1-50 μM in the presence of 0.5 mM AA, with a detection limit 1.0 μM (S/N = 3). This sensor was stable, reproducible and outstanding for long-term use. 相似文献
7.
Qianwen Lian Zhifang He Qian He Ai Luo Kaiwang Yan Dongxia Zhang Xiaoquan Lu Xibin Zhou 《Analytica chimica acta》2014
A new type of tryptophan-functionalized graphene nanocomposite (Trp-GR) was synthesized by utilizing a facile ultrasonic method via π–π conjugate action between graphene (GR) and tryptophan (Trp) molecule. The material as prepared had well dispersivity in water and better conductivity than pure GR. The surface morphology of Trp-GR was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Raman spectroscopy. The electrochemical behaviors of ascorbic acid (AA), dopamine (DA), and uric acid (UA) were investigated by cyclic voltammetry (CV) on the surface of Trp-GR. The separation of the oxidation peak potentials for AA–DA, DA–UA and UA–AA was about 182 mV, 125 mV and 307 mV, which allowed simultaneously determining AA, DA, and UA. Differential pulse voltammetery (DPV) was used for the determination of AA, DA, and UA in their mixture. Under optimum conditions, the linear response ranges for the determination of AA, DA, and UA were 0.2–12.9 mM, 0.5–110 μM, and 10–1000 μM, with the detection limits (S/N = 3) of 10.09 μM, 0.29 μM and 1.24 μM, respectively. Furthermore, the modified electrode was investigated for real sample analysis. 相似文献
8.
The electrochemistry of dopamine (DA) was studied by cyclic voltammetry at a glassy carbon electrode modified by a gel containing multi-walled carbon nanotubes (MWNTs) and room-temperature ionic liquid of 1-octyl-3-methylimidazolium hexafluorophosphate (OMIMPF6). The thickness of gel on the surface of the electrode has to be controlled carefully because the charging currents increase with the modified layer being thicker. The anodic peaks of DA, ascorbic acid (AA) and uric acid (UA) in their mixture can be well separated since the peak potential of AA is shifted to more negative values, while that of UA is shifted to more positive values due to the modified electrode. At pH 7.08 the three peaks are separated ca. 0.20 and 0.15 V, respectively; hence DA can be determined in the presence of UA and more than 100 times excess of AA. Under optimum conditions linear calibration graphs were obtained over the DA concentration range 1.0 × 10−6 to 1.0 × 10−4 M. The detection limit of the current technique was found to be 1.0 × 10−7 M based on the signal-to-noise ratio of 3. The modified electrode has been successfully applied for the assay of DA in human blood serum. This work provides a simple and easy approach to selectively detect dopamine in the presence of ascorbic acid and uric acid. 相似文献
9.
Functionalized-graphene modified graphite electrode for the selective determination of dopamine in presence of uric acid and ascorbic acid 总被引:2,自引:0,他引:2
Mallesha M Manjunatha R Nethravathi C Suresh GS Rajamathi M Melo JS Venkatesha TV 《Bioelectrochemistry (Amsterdam, Netherlands)》2011,81(2):104-108
Graphene is chemically synthesized by solvothermal reduction of colloidal dispersions of graphite oxide. Graphite electrode is modified with functionalized-graphene for electrochemical applications. Electrochemical characterization of functionalized-graphene modified graphite electrode (FGGE) is carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The behavior of FGGE towards ascorbic acid (AA), dopamine (DA) and uric acid (UA) has been investigated by CV, differential pulse voltammetry (DPV) and chronoamperommetry (CA). The FGGE showed excellent catalytic activity towards electrochemical oxidation of AA, DA and UA compared to that of the bare graphite electrode. The electrochemical oxidation signals of AA, DA and UA are well separated into three distinct peaks with peak potential separation of 193mv, 172mv and 264mV between AA-DA, DA-UA and AA-UA respectively in CV studies and the corresponding peak potential separations in DPV mode are 204mv, 141mv and 345mv. The FGGE is successfully used for the simultaneous detection of AA, DA and UA in their ternary mixture and DA in serum and pharmaceutical samples. The excellent electrocatalytic behavior of FGGE may lead to new applications in electrochemical analysis. 相似文献
10.
A kinetic stopped-flow method is described for the simultaneous determination of uric acid and ascorbic acid with tris (2,2'-bipyridine)iron(III). For the least favourable ratios of uric to ascorbic acid, in a total concentration of 10-5 M, the error in the determination of uric acid is estimated at ±10%. 相似文献
11.
A glassy carbon electrode modified with poly(alizarin red)/electrodeposited graphene (PAR/EGR) composite film was prepared and applied to detect ciprofloxacin (CPFX) in the presence of ascorbic, uric acid and dopamine. The morphology and interface property of PAR/EGR films were examined by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy (EIS). The electrocatalytic oxidation of CPFX on AR/EGR was investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The linearity ranged from 4 × 10−8 to 1.2 × 10−4 M with a detection limit (S/N = 3) of 0.01 μM. The modified electrode could be applied to the individual determination of CPFX as well as the simultaneous determination of CPFX, ascorbic acid, uric acid and dopamine. This method proved to be a simple, selective and rapid way to determine CPFX in pharmaceutical preparation and biological media. 相似文献
12.
The coulometric determination of uric acid in human urine is done using porous carbon felt electrodes containing electrolyte. The diluted human urine is dropped on the carbon felt surface and uric acid is completely electrically oxidized in a few minutes. The coulombs consumed by interferences contained in human urine are determined by measuring the electrolytic oxidation of the same diluted human urine to which uricase is added. The current efficiencies of uric acid are nearly 100% (RSD < 1%). The results are in fairly good agreement with those obtained by sepectrophotometry. 相似文献
13.
The cysteamine (CA) was bound onto surface of the pretreated glassy carbon electrode (GC) with cyclic voltammetry (CV). Gold nanoparticles were self-assembled to the electrode binding with cysteamine via strong AuS covalent bond to fabricate the nano-Au self-assembled modified electrode (nano-Au/CA/GC). The modified electrode was characterized with cyclic voltammetric and ac impedance methods. The electrochemical behavior of dopamine (DA) on the modified electrode was investigated with cyclic voltammetry and differential pulse voltammetry (DPV). A well-defined redox peaks of DA on the nano-Au/CA/GC electrode were obtained at Epa = 0.175 V and Epc = 0.146 V (vs. SCE), respectively. The peak current of DA is linear with the concentration of DA in the range of 1.0 × 10−8 mol L−1 to 2.5 × 10−5 mol L−1, with the correlation coefficient of 0.998. The detection limit is 4.0 × 10−9 mol L−1 (S/N = 3). The modified electrode exhibited an excellent reproducibility, sensibility and stability for determination of DA in the presence of high concentration AA, and can be applied to determinate dopamine injection, with satisfied result. 相似文献
14.
A simple modified TiO(2) nanotubes electrode was fabricated by electrodeposition of Pd, Pt and Au nanoparticles. The TiO(2) nanotubes electrode was prepared using the anodizing method, followed by modifying Pd nanoparticles onto the tubes surface, offering a uniform conductive surface for electrodeposition of Pt and Au. The performance of the modified electrode was characterized by cyclic voltammetry and differential pulse voltammetry methods. The Au/Pt/Pd/TiO(2) NTs modified electrode represented a high sensitivity towards individual detection of dopamine as well as simultaneous detection of dopamine and uric acid using 0.1 M phosphate buffer solution (pH 7.00) as the base solution. In both case, electro-oxidation peak currents of dopamine were linearly related to accumulated concentration over a wide concentration range of 5.0 × 10(-8) to 3.0 × 10(-5) M. However in the same range of dopamine concentration, the sensitivity had a significant loss at Pt/Pd/TiO(2) NTs electrode, suggesting the necessity for Au nanoparticles in modified electrode. The limit of the detection was determined as 3 × 10(-8) M for dopamine at signal-to-noise ratio equal to 3. Furthermore, the Au/Pt/Pd/TiO(2) NTs modified electrode was able to distinguish the oxidation response of dopamine, uric acid and ascorbic acid in mixture solution of different acidity. It was shown that the modified electrode possessed a very good reproducibility and long-term stability. The method was also successfully applied for determination of DA in human urine samples with satisfactory results. 相似文献
15.
A novel amperometric sensor for the determination of uric acid was fabricated using room temperature ionic liquid and nickel hexacyanoferrate nanoparticle composite which was immobilized on paraffin wax impregnated graphite electrode. The nickel hexacyanoferrate nanoparticle was characterized by UV-vis, X-ray diffraction and field emission scanning electron microscopy. The electrochemical behavior of the modified electrode was investigated in detail by electrochemical impedance spectroscopy, cyclic voltammetry and differential pulse voltammetry. Various experimental parameters influencing the electrochemical behavior of the modified electrode were optimized by varying the supporting electrolyte, scan rate and pH. The apparent electron transfer rate constant (K(s)) and charge transfer coefficient (α) of the modified electrode were found to be 1.358(± 0.02)cm/s and 0.65, respectively from cyclic voltammetry. The sensor exhibited an excellent electrocatalytic activity towards the oxidation of uric acid. The interference from ascorbic acid was easily overcome by coating the modified electrode with PEDOT layer. Under optimal condition, the determination range for uric acid is from 1.0 × 10(-6)M to 2.6 × 10(-3)M and the detection limit was 3.3 × 10(-7)M (3σ). The proposed method has been used for the determination of uric acid in human urine samples. 相似文献
16.
Hong Yao Yuanyuan Sun Xinhua Lin Yuhai Tang Ailin Liu Guangwen Li Wei Li Shaobo Zhang 《Analytical sciences》2007,23(6):677-682
An electropolymerized film of eriochrome black T (EBT) has been prepared at a glassy carbon electrode (GCE) by cyclic voltammetry (CV). The poly(EBT) membrane at GCE exhibits an excellent electrocatalytic activity towards the oxidation of epinephrine (EP), ascorbic acid (AA) and uric acid (UA) in acidic solution and reduced the overpotential for the oxidation of EP. The poly(EBT)-coated electrode could separately detect EP, AA and UA in their mixture with the potential differences of 180 and 160 mV for EP-AA and UA-EP, respectively, which are large enough to allow for determination of EP in the presence of AA and UA. Using differential pulse voltammetry, the peak current of EP recorded in pH 3.5 solution was linearly dependent on EP's concentration in the range of 2.5 - 50 microM. Due to its good selectivity and stability, the polymer-coated GCE was successfully applied to the determination of EP in real samples. 相似文献
17.
聚赖氨酸修饰电极在抗坏血酸共存时测定肾上腺素 总被引:3,自引:0,他引:3
在pH8.0磷酸盐缓冲溶液(PBS)中利用循环伏安法制备了聚赖氨酸修饰电极,在pH4.0 PBS中,聚赖氨酸膜对肾上腺素(EP)的电化学氧化具有明显的催化作用.利用循环伏安法测定EP还原峰电流可排除抗坏血酸(AA)干扰.肾上腺素还原峰电流与其浓度分别在6.3×10-7mol/L~1.0×10-5 mol/L与1.0×10-5mol/L~1.2×10-4 mol/L范围内呈良好线性关系,相关系数分别为0.9978与0.9975,;检出限(S/N=3)为7.2×10-8mol/L.该方法具有良好的灵敏度、选择性,已用于针剂样品分析. 相似文献
18.
LaFeO3 nanoparticles of approximately 22 nm in size were synthesized and characterized by XRD and TEM. A novel glassy carbon electrode modified with LaFeO3 nanoparticles was constructed and characterized by electrochemical impedance spectroscopy and cyclic voltammetry. The modified electrode exhibited strong promoting effect and high stability toward the electrochemical oxidation of dopamine (DA), which gave reversible redox peaks with a formal potential of 0.145 V (vs. Ag/AgCl) in pH 7.0 phosphate buffer solution. The anodic peak current (measured by constant potential amperometry) increased linearly with the concentration of dopamine in the range from 1.5?×?10?7 to 8.0?×?10?4 M. The detection limit was 3.0?×?10?8 M. The relative standard deviation of eight successive scans was 3.47% for 1.0?×?10?6 M DA. The interference by ascorbic acid was eliminated efficiently. The method was used to determine DA in dopamine hydrochloride injections and showed excellent sensitivity and recovery. 相似文献
19.
This paper describes a facile and effective method to synthesize gold nanoflowers (AuNFs) by a controllable electrodeposition method induced by a L-cysteamine (L-Cys) monolayer self-assembled on the surface of a gold electrode. The AuNFs/L-Cys/Au electrodes were characterized by field emission scanning electron microscopy (FE-SEM), cyclic voltammetry, and AC impedance spectroscopy methods. This obtained AuNFs/L-Cys/Au electrode exhibits excellent electrocatalytic activity towards the oxidation of dopamine (DA) due to the synergistic effect of AuNFs and a L-Cys monolayer. Differential pulse voltammetry (DPV) experiment results show that the oxidation peak of DA is separated from the oxidation peaks of ascorbic acid (AA) and uric acid (UA), which can be used to detect DA in the presence of AA and UA, and the results are satisfactory. 相似文献
20.
Gang Li Suling Yang Lingbo Qu Ran Yang Jianjun Li 《Journal of Solid State Electrochemistry》2011,15(1):161-166
A Nafion/multi-wall carbon nanotubes (MWNT) composite film-modified electrode was fabricated. The modified electrode showed
excellent electrocatalytic activity toward ascorbic acid (AA) and uric acid (UA) in 0.1-mol L−1 NaCl medium (pH 6.5). Compared to the bare electrode that only displayed a broad and overlapped oxidation peak, the Nafion/MWNT
film-modified electrode not only remarkably enhanced the anodic peak currents of AA and UA but also avoided the overlapping
of the anodic peaks of AA and UA with a 320-mV separation of both peaks. Under the optimized conditions, the peak currents
of AA and UA were proportional to their concentration at the ranges of 8.0 × 10−5 to 6.0 × 10−3 mol L−1 and 6.0 × 10−7 to 8.0 × 10−5 mol L−1, respectively. The proposed method was used for the detection of AA and UA in real samples with satisfactory results. 相似文献