首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Acrylic acid was first electropolymerized on the surface of a gold electrode. Then, polyaniline (PANI) was electrodeposited on the poly(acrylic acid) (PAA) network to give a PANI–PAA composite film. Scanning electron microscopy and electrochemical studies confirmed the formation of PANI–PAA composite which exhibited excellent electroactivity over a wide pH range. The electro-oxidation of ascorbic acid (AA) was studied in detail. The modified electrode exhibits significantly reduced oxidation overpotential. The response towards AA is linear in the range 1.0 μM to 9.3 mM (R?=?0.9997, n?=?33) at a potential of 0.1 V (vs. SCE). The sensitivity is 207 μA mM-1 cm-2, and the detection limit is 1.0 μM (S/N?=?3). Interferences by uric acid and dopamine are negligible. The electrode thus enables sensitive and selective determination of AA, with a performance superior to many other PANI–based ascorbate sensors.  相似文献   

2.
This study introduces a new surface-renewable electrode based on a sol–gel derived graphene ceramic composite. The electrode was prepared by dispersing graphene nanosheets into a solution of the sol–gel precursors containing methyl triethoxysilane in methanol and hydrochloric acid. During hydrolysis of methyl triethoxysilane, the graphene nanosheets are trapped in the gel. After moulding and drying the composite, it can be used as a surface-renewable electrode to which we refer as a graphene ceramic composite electrode (GCCE). Cyclic voltammograms of the hexacyanoferrate(II/III) model redox system at the GCCE were compared to those obtained with a conventional carbon ceramic electrode and showed a highly improved electron transfer rate at the GCCE. The electrocatalytic oxidation of ascorbic acid as a model analyte was then studied at working potential of 50 mV and over the 3–84 μM concentration range. It revealed a sensitivity of 6.06 μA μM?1 cm?2 and a detection limit of 0.82 μM. The GCCE was successfully applied to the determination of ascorbic acid in orange juice and urine samples. Advantages such as good mechanical and chemical stability, ease of fabrication, and reproducible preparation make the GCCE a potentially useful and widely applicable renewable electrode for use in routine analysis. Fig. 1
(Left) FESEM image and photograph of the graphene ceramic composite electrode (GCCE); (right) the cyclic voltammogram of the renewable GCCE in 5 mM K3[Fe(CN)6] solution containing 0.1 M KNO3 at scan rate of 100 mV s?1   相似文献   

3.
A voltammetric sensor is presented for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA). It is based on a gold electrode (GE) modified with carboxyl-functionalized graphene (CFG) and silver nanocube functionalized DA nanospheres (AgNC@PDA-NS). The AgNC@PDA-NS nanocomposite was characterized by scanning electron microscopy and UV-Vis spectroscopy. The electrochemical behavior of the modified electrode was evaluated by electrochemical impedance spectroscopy, cyclic voltammetry and differential pulse voltammetry. The modified electrode displays good electrocatalytic activity towards DA (typically at 0.14 V vs. Ag/AgCl) and UA (typically at 0.29 V vs. Ag/AgCl) even in the presence of ascorbic acid. Response to DA is linear in the concentration range of 2.5 to 130 μM with a detection limit of 0.25 μM. Response to UA is linear in the concentration range of 10 to 130 μM with a detection limit of 1.9 μM. In addition, the sensitivity for DA and UA is 0.538 and 0.156 μA μM?1 cm?2, respectively. The modified electrode also displays good stability, selectivity and reproducibility.
Graphical abstract The gold electrode modified with polydopamine nanospheres functionalized with silver nanocube and carboxylated graphene is used for simultaneous determination of DA and UA in the presence of AA, with wide linear range and low detection limit.
  相似文献   

4.
We report on the synthesis and characterization of activated carbon–ethylenediamine–cobalt(II) tetracarboxyphthalocyanine conjugate (AC–CONHCH2CH2NH2–CoPc) and its electrocatalytic behavior for oxidation of ascorbic acid. Ultraviolet–visible (UV–Vis), Fourier-transform infrared (FTIR), and electrochemical impedance spectroscopies, and cyclic and square-wave voltammetry were used to characterize the electrode modifiers and modified glassy carbon electrode. The limit of detection was found to be 0.26 µm using 3δ notation. The linear dynamic range was from 1.5 × 10?4 to 1 × 10?2 M with electrode sensitivity of 0.01 A mol?1 L cm?2. A Tafel slope of 200.8 mV decade?1 was found. The concentration of ascorbic acid in the tablet was 0.034 M. Oxalic acid showed no interference in ascorbic acid determination.  相似文献   

5.
《Analytical letters》2012,45(16):2618-2630
A carbon paste electrode (CPE), modified with novel hydroquinone/TiO2 nanoparticles, was designed and used for simultaneous determination of ascorbic acid (AA), uric acid (UA) and folic acid (FA). The magnitude of the peak current for modified TiO2-nanoparticle CPE (MTNCPE) increased sharply in the presence of ascorbic acid and was proportional to its concentration. A dynamic range of 1.0–1400.0 μM, with the detection limit of 6.4 × 10?7 M for AA, was obtained using the DPV technique (pH = 7.0). The prepared electrode was successfully applied for the determination of AA, UA, and FA in real samples.  相似文献   

6.
An inorganic–organic composite material was prepared by the insertion of bis(ethylhexyl)hydrogen phosphate (BEHP) within the interlayer space of a nickel-aluminum–layered double hydroxide (NiAl LDH). X-ray diffraction, thermogravimetric analysis, and Fourier transform infrared were used to characterize the pristine and modified LDH (NiAl–BEHP), which together confirm the intercalation of BEHP in the mineral structure. Cyclic voltammetry using [Fe(CN)6]3? as an anionic redox probe demonstrated a significant decrease in the anion exchange capacity of NiAl upon modification. Used as electrode modifier for methyl parathion (MP) detection, a remarkable increase in MP signal on NiAlBEHP–modified glassy carbon electrode (GCE/NiAl–BEHP) was observed, because of the high hydrophobicity character of the modified LDH. The signal assigned to the electroactivity of the nitro group being less stable than that of the reduction of the nitroso group, the use of both functions was explored for the calibration experiments. Sensitivities of 0.79 μA μM?1 and 0.14 μA μM?1 were obtained, with detection limits of 2.28 × 10?8 and 12.4 × 10?8 mol L?1 for nitro and nitroso groups, respectively. However, the linearity range was more important for the nitroso group (0.5–12 μM) as compared to the nitro group (0.5–3.5 μM). Moreover, the signal of the nitroso group showed poor interference with some chemical species likely to be encountered in the presence of MP. The GCE/NiAl-BEHP–modified electrode was particularly effective for the differentiation of 4-nitrophenol (4-NP) from MP. Interestingly, the decrease in the sensor sensitivity was negligible (0.13 μA μM?1) when the calibration curve of MP was plotted in the presence of 1 μM of 4-NP. The poor efficiency of the sensor to quantify 4-NP was probably because of the high organophilic character of the electrode material. The developed method was successfully applied to quantify MP in spring water.  相似文献   

7.
This paper describes the development of a simple and efficient nanostructured platform based on multi-walled carbon nanotubes (MWCNT) functionalized with an in situ generated vanillic acid (VA) polymer. It was used as an analytical sensor for the simultaneous determination of ascorbic acid (AA), dopamine (DA), and uric acid (UA). The electropolymerization process of VA, performed on MWCNT-modified glassy carbon electrode, produces three redox systems based on quinone/hydroquinone functionality, as observed by cyclic voltammetry. The amperometric sensor has as figures of merit for the simultaneous determination of AA, DA, and UA the following values: for AA, a linear range of 5–120 μM and detection limit of 3.5 μM; for DA, a linear range of 5–120 μM and detection limit of 4.5 μM; and for UA, a linear range of 5–120 μM and a detection limit of 1.5 μM. From the obtained performance, the development of the platform based on MWCNT/poly-VA is justified for the simultaneous determination of AA, DA, and UA.  相似文献   

8.
We describe the use of individual zinc oxide (ZnO) micro/nanowires in an electrochemical biosensor for uric acid. The wires were synthesized by chemical vapor deposition and possess uniform morphology and high crystallinity as revealed by scanning electron microscopy, X-ray diffraction, and photoluminescence studies. The enzyme uricase was then immobilized on the surface of the ZnO micro/nanowires by physical adsorption, and this was proven by Raman spectroscopy and fluorescence microscopy. The resulting uric acid biosensor undergoes fast electron transfer between the active site of the enzyme and the surface of the electrode. It displays high sensitivity (89.74 μA cm?2 mM?1) and a wide linear analytical range (between 0.1 mM and 0.59 mM concentrations of uric acid). This study also demonstrates the potential of the use of individual ZnO micro/nanowires for the construction of highly sensitive nano-sized biosensors.
Figure
Individual ZnO micro/nanowire based electrochemical biosensor was constructed. The biosensor displayed a higher sensitivity of 89.74 μA cm?2 mM?1 for uric acid detection.  相似文献   

9.
A reliable and simple sensor was fabricated by modifying a carbon paste electrode with nanosized gold particles and poly (glutamic acid) for determination of paracetamol (PAR). The modified electrode exhibited an effective catalytic response to the oxidation and reduction of PAR with good reproducibility and stability. The determination was carried out by differential pulse adsorptive stripping voltammetry after a 30 s accumulation time with an open circuit potential and under stirring. The calibration curve is linear in the range from 0.05 to 70 μM of PAR (with a correlation coefficient of 0.9990), and the sensitivity is 1.51 μA·μM-1. The modified electrode was used to detect PAR in commercial tablets.  相似文献   

10.
The present work is based on the use of a redox mediator containing an azo group for the selective determination of dopamine in the presence of uric acid and ascorbic acid by electrochemical method. A modified electrode was prepared by electrochemical polymerization of the poly 2-napthol orange film (P2NO) on the paraffin wax-impregnated graphite electrode (PIGE) by applying potential between ?0.6 and 0.8 V at scan rate of 50 mV s?1 for 30 segments. The modified P2NO film electrode was characterized by ATR-IR spectroscopy, FE-SEM, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), differential pulse voltammetry (DPV), hydrodynamic voltammetry (HDV), and chronoamperometry (CA). The P2NO film modified electrode exhibited selective determination of dopamine in the presence of uric acid and ascorbic acid, and the electrocatalytic activity for oxidation of dopamine was excellent. The linear range for the determination of dopamine was 0.6 to 250 μM with a limit of detection of 0.13 μM. The modified P2NO electrode showed good stability and reproducibility. The modified electrode was used for real sample analysis such as human blood serum, rat blood serum, and pharmaceutical samples (dopamine hydrochloride injection). The results obtained were found to be satisfactory.  相似文献   

11.
We have fabricated, in a single step, carbon ceramic electrodes modified with a poly(acridine orange) film containing reduced graphene oxide. They display electrocatalytic activity to ascorbic acid (AA) and uric acid (UA) at pH 4.5. The anodic peak potentials of AA and UA are separated by 276 mV so that they can be well resolved in cyclic voltammetry. UA and AA were simultaneously determined in a mixture at working potentials of 170 and 400 mV, respectively. Under optimized conditions, the calibration curves for AA and UA cover the 0.8–5,000 μM and 0.6–900 μM concentration range, respectively, while detection limits are 0.3 μM and 0.2 μM. The electrode was applied to determine AA and UA in urine samples.
Figure
DPV curves of RGO–PAO/CCE in the phosphate buffer solution (pH 4.5) containing 5.0?×?10?5 mol L?1 AA with different concentration of UA (a?→?f: 0, 1, 3, 5, 7, 9?×?10?6 mol L?1)  相似文献   

12.
Menadione cyclic voltammograms show a pair of redox steps on glassy carbon electrode in 0.1 M H3PO4 with potential separation of 343 mV. Cationic, nonionic, and anionic surfactants micellar media significantly decrease the menadione peak potential separation. Statistically significant increase of menadione reduction current (3- and 4.4-fold) has been observed in Triton X 100 and sodium dodecyl sulfate (SDS) micellar media, respectively. Electrochemical reduction of menadione in 9 mM SDS micellar media is reversible diffusion-controlled one-electron process corresponding to formation of relatively stable semiquinone anion radical. The linear dynamic ranges of menadione determination are 7–560 and 600–2,550 μM with the limits of detection and quantification of 1.66 and 5.53 μM, respectively. The current concentration sensitivity is (8.6?±?0.2)?×?103 μA μM?1. The voltammetric method for the determination of menadione in pharmaceutical “Aekol” based on preliminary extraction with ethanol has been developed.  相似文献   

13.
A novel modified glassy carbon electrode with ytterbium fluoride nanoparticles (YFNPs)-multiwalled carbon nanotubes (MWCNTs) was fabricated and then successfully used for the simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA). YFNPs were successfully coated on the MWCNTs via the intermediate of noncovalent hydrophobic interactions of the MWCNTs surface with sodium dodecyl sulfate. The YFNPs and immobilization of YFNPs on MWCNTs were confirmed by transmission electron microscopy. The particle size of YFNPs was measured to be around 45 nm. The catalytic peak currents for AA, DA and UA were linearly dependent on their concentrations in the range of 2.0–600.0, 2.0–560.0 and 1.8–640.0 μM, respectively, with the corresponding detection limits of 0.77, 0.22 and 0.17 μM. The modified electrode provided good sensitivity and stability, and was successfully applied for the simultaneous determination of AA, DA and UA in human blood serum and urine samples.  相似文献   

14.

This study introduces a new surface-renewable electrode based on a sol–gel derived graphene ceramic composite. The electrode was prepared by dispersing graphene nanosheets into a solution of the sol–gel precursors containing methyl triethoxysilane in methanol and hydrochloric acid. During hydrolysis of methyl triethoxysilane, the graphene nanosheets are trapped in the gel. After moulding and drying the composite, it can be used as a surface-renewable electrode to which we refer as a graphene ceramic composite electrode (GCCE). Cyclic voltammograms of the hexacyanoferrate(II/III) model redox system at the GCCE were compared to those obtained with a conventional carbon ceramic electrode and showed a highly improved electron transfer rate at the GCCE. The electrocatalytic oxidation of ascorbic acid as a model analyte was then studied at working potential of 50 mV and over the 3–84 μM concentration range. It revealed a sensitivity of 6.06 μA μM−1 cm−2 and a detection limit of 0.82 μM. The GCCE was successfully applied to the determination of ascorbic acid in orange juice and urine samples. Advantages such as good mechanical and chemical stability, ease of fabrication, and reproducible preparation make the GCCE a potentially useful and widely applicable renewable electrode for use in routine analysis.

(Left) FESEM image and photograph of the graphene ceramic composite electrode (GCCE); (right) the cyclic voltammogram of the renewable GCCE in 5 mM K3[Fe(CN)6] solution containing 0.1 M KNO3 at scan rate of 100 mV s−1

  相似文献   

15.
Differential pulse and cyclic voltammetry were applied for the oxidation of mixture of uric acid and ascorbic acid at the surface of carbon paste/cobalt Schiff base composite electrode. The electrooxidation of these compounds at bare electrode is sluggish, and there is no suitable peak separation between them. However, using cobalt methyl salophen as modifier, two well-defined anodic waves with a considerable enhancement in the peak current and a remarkable peak potential separation near 315 mV are obtained. It can improve the kinetics of electron transfer for both compounds remarkably. All these improvements are created because of the electrocatalytic property of cobalt Schiff base complex. The effect of some parameters such as pH and scan rates were studied. All the anodic peak currents for the oxidation of ascorbic acid and uric acid shifted toward more negative potential with an increase in pH, revealing that protons have taken part in their electrode reaction processes. The best peak separation with appropriate current was obtained for pH 4.0. A linear range of 5.0?×?10?4 to 1.0?×?10?8 and 1.0?×?10?3 to 1.0?×?10?8 M with detection limit of 8.0?×?10?9 and 8.0?×?10?9 M was obtained for ascorbic acid and uric acid using differential pulse voltammetry at the surface of modified electrode, respectively. Analytical utility of the modified electrode has been examined successfully using human urine samples and vitamin C commercial tablets.  相似文献   

16.
A nafion covered carbon nanotubes-paste electrode modified with poly(m-ferrocenylaniline), (Nf/p(FcAni)-CNTsPE), provides a novel voltammetric sensor for the selective determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA). We studied the electrochemical activity of Nf/p(FcAni)-CNTsPE toward DA, UA, and AA by differential pulse voltammetry (DPV). DA and UA anodic peaks appear at 0.30 and 0.45 V, respectively while an anodic peak for AA was not observed. DPV oxidation peak values are linearly dependent on DA concentration over the range 1–150 μM (r2 = 0.992), and on UA concentration over the range 5–250 μM (r2 = 0.997). DA and UA detection limits are estimated to be 0.21 and 0.58 μM, respectively. The modified electrode shows both good selectivity and reproducibility for the selective determination of DA and UA in real samples. Finally, the modified electrode was successfully applied for the determination of DA and UA in pharmaceutical or biological sample fluids.  相似文献   

17.
We describe a chemical exfoliation method for the preparation of MoS2 nanosheets. The nanosheets were incorporated into poly(3,4-ethylenedioxythiophene) (PEDOT) by electrodeposition on a glassy carbon electrode (GCE) to form a nanocomposite. The modified GCE is shown to enable simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Due to the synergistic effect of MoS2 and PEDOT, this electrode displays better properties in terms of electrocatalytic oxidation of AA, DA and UA than pure PEDOT, which is illustrated by cyclic voltammetry and differential pulse voltammetry (DPV). Under optimum conditions and at pH 7.4, the respective sensitivities and best working potentials are as follows: AA: 1.20 A?mM?1?m?2, 30 mV; DA: 36.40 A?mM?1?m?2, 210 mV; UA: 105.17 A?mM?1?m?2, 350 mV. The calculated detection limits for AA, DA and UA are 5.83 μM, 0.52 μM and 0.95 μM, respectively. The modified electrode was applied to the detection of the three species in human urine samples and gave satisfactory results.
Graphical abstract MoS2 nanosheets were prepared by a facile chemical exfoliation method. MoS2 and poly(3,4-ethylenedioxythiophene) nanocomposite modified glassy carbon electrodes were fabricated, which are shown to enable simultaneous determination of ascorbic acid, dopamine and uric acid with high sensitivity and selectivity.
  相似文献   

18.
A polymerized film of Adizol Black B (ABB) on the surface of glassy carbon (GC) electrode was prepared for the simultaneous determination of ascorbic acid (AA), epinephrine (EP), and uric acid (UA). This new electrode presented an excellent electrocatalytic activity towards the oxidation of AA, EP, and UA by differential pulse voltammetry method. The oxidation peaks of the three compounds were well defined and had the enhanced peak currents. The separation of the oxidation peak potentials for AA–EP and EP–UA were about 180 and 130 mV, respectively. The calibration curves obtained for AA, EP, and UA were in the ranges of 2.0–1,970.0, 0.1–64.0, and 0.1–1,700.0 μmol L–1, respectively. The detection limits (S/N?=?3) were 0.01, 0.007, and 0.02 μmol L–1 for AA, EP, and UA, respectively. The diffusion coefficient and the catalytic rate constant for the oxidation reaction of EP at poly(ABB) film-coated GC electrode were calculated as 1.54(±0.10)?×?10?4 cm2 s?1 and 4.5?×?103 mol?1 L s?1, respectively. The present method was applied to the determination of EP in pharmaceutical, AA in commercially available vitamin C tablet, and UA in urine samples.  相似文献   

19.
《Analytical letters》2012,45(12):1976-1988
A sensitive and selective electrochemical method for the simultaneous determination of dopamine (DA) and uric acid (UA) was developed using a pyrogallol red modified carbon paste electrode. Under the optimized conditions, the peak current was linearly dependent on 1.0–700.0 μmol L?1 DA and 50.0–1000.0 μmol L?1 UA. The detection limits for DA and UA were 0.78 μmol L?1 and 35 μmol L?1, respectively. Finally, this method was also examined for the determination of DA and uric acid in real samples such as drugs and urine.  相似文献   

20.
《Analytical letters》2012,45(18):2809-2822
Development and use of highly ordered, vertically aligned TiO2 nanotube arrays modified with gold nanoparticles for the selective detection of ascorbic acid (AA) in the presence of uric acid and glucose are reported here. Gold nanoparticles were electrodeposited on the Nanotube arrays by CV. The sensor was characterized using SEM, EDS, CV, and EIS. It showed very good performance with a sensitivity of 46.8 μA mM?1 cm?2, response time below 2 seconds and linearity in the range of 1 μM to 5 mM with a detection limit of 0.1 μM and was tested for the AA concentration in pharmaceutical preparations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号