首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 953 毫秒
1.
For pharmacokinetic and toxicokinetic purpose a simple HPLC-UV method has been developed and validated for the estimation of DRF-4848, a novel COX-2 inhibitor in rat plasma. A liquid-liquid extraction was used to extract DRF-4848 and internal standard (IS, DRF-4367) from rat plasma. The analysis was performed on a C(18) column with UV detection at 285 nm. The isocratic mobile phase, 0.01 M potassium dihydrogen ortho phosphate (pH 3.2) and acetonitrile (50:50, v/v) was run at a flow rate of 1 mL/min. The retention times of DRF-4848 and IS were 6.8 and 11.2 min, respectively. Absolute recovery for analyte and IS was >80% from rat plasma. A linear response was observed over a concentration range 0.1-20 microg/mL. The lower limit of quantification (LLOQ) of DRF-4848 was 0.1 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.1, 0.3, 8.0 and 15.0 microg/mL, were in the range 1.74-8.70% relative standard deviation (RSD) and 0.75-8.43% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.29-116.51% of the nominal values. Analyte and IS were stable in the battery of stability studies viz., benchtop, autosampler, long-term and freeze/thaw cycles.  相似文献   

2.
A specific, accurate, precise and reproducible high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous quantitation of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide and celecoxib in human plasma. The method employed a simple liquid-liquid extraction of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide and celecoxib and internal standard (IS, DRF-4367) from human plasma (500 microL) into acetonitirile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). The chromatographic separation was achieved by gradient elution consisting of 0.05 M formic acid (pH 3)-acetonitrile-methanol-water at a flow rate of 1.0 mL/min. The eluate was monitored using an ultraviolet (UV) detector set at 235 nm. The ratio of peak area of each analyte to IS was used for quantification of plasma samples. Nominal retention times of etoricoxib, salicylic acid, valdecoxib, ketoprofen, nimesulide, IS and celecoxib were 15.63, 17.20, 21.66, 24.95, 26.27, 30.24 and 32.22 min, respectively. The standard curve for etoricoxib, salicylic acid, valdecoxib, ketoprofen and celecoxib was linear (r2 > 0.999) in the concentration range 0.1-50 microg/mL and for nimesulide (r2 > 0.999) in the concentration range 0.5-50 microg/mL. Absolute recovery was >83% from human plasma for all the analytes and IS. The lower limit of quantification (LLOQ) of nimesulide was 0.5 microg/mL and for etoricoxib, salicylic acid, valdecoxib, ketoprofen and celecoxib the LLOQ was 0.1 microg/mL. The inter- and intra-day precisions in the measurement of QC samples, 0.1, 0.3, 15.0 and 40.0 microg/mL (for all analytes except nimesulide), were in the range 2.29-9.37% relative standard deviation (RSD) and 0.69-10.28% RSD, respectively. For nimesulide the inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.5, 1.5, 15.0 and 40.0 microg/mL, were in the range 3.21-7.37% RSD and 0.97-7.06% RSD, respectively. Accuracy in the measurement of QC samples for all analytes was in the range 91.03-106.38% of the nominal values. All analytes including IS were stable in the battery of stability studies, viz. bench top, autosampler and freeze-thaw cycles. Stability of all analytes was established for 21 days at -20 degrees C. The application of the assay in an oral pharmacokinetic study in rats co-administered with celecoxib and valdecoxib is described.  相似文献   

3.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of ragaglitazar [(-) DRF 2725, NNC 61-0029], a novel anti-diabetic agent, in rat plasma. The assay procedure involved simple liquid/liquid extraction of ragaglitazar and internal standard (IS, troglitazone) from plasma into ethyl acetate. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100 - 5C(18) column (4.6 x 250 mm, 5 micro m). Mobile phase consisting of 0.01 M potassium dihydorgen ortho phosphate (pH 3.2) and acetonitrile (30:70, v/v) was used at a flow rate of 1.0 mL/min. The eluate was monitored using an UV detector set at 240 nm. Ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of IS and ragaglitazar were 6.9 and 12.2 min, respectively. The standard curve for ragaglitazar was linear (r(2) > 0.999) in the concentration range 0.2-100 micro g/mL. Absolute recovery was >87% from rat plasma for both analyte and IS. The lower limit of quantification (LLOQ) of ragaglitazar was 0.2 micro g/mL. The inter- and intra-day precision in the measurement of quality control (QC) samples, 0.2, 1.0, 5.0 and 50 micro g/mL, were in the range 1.32-3.70% relative standard deviation (RSD) and 1.19-9.39% RSD, respectively. Accuracy in the measurement of QC samples was in the range 94.28-107.45%. Analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze/thaw cycles. Stability of ragaglitazar was established for 1 month at -20 degrees C. The application of the assay to a pharmacokinetic study in rats is described.  相似文献   

4.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

5.
A specific, accurate, precise and reproducible high-performance liquid chromatography (HPLC) method was developed for the estimation of rosuvastatin (RST), a novel, synthetic and potent HMG-CoA inhibitor in rat plasma. The assay procedure involved simple liquid-liquid extraction of RST and internal standard (IS, ketoprofen) from a small plasma volume directly into acetonitrile. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Kromasil KR 100-5C18 column (4.6 x 250 mm, 5 microm). Mobile phase consisting of 0.05 m formic acid and acetonitrile (55:45, v/v) was used at a flow rate of 1.0 mL/min for the effective separation of RST and IS. The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 240 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of RST and IS were 8.6 and 12.5 min, respectively. The standard curve for RST was linear (r2 > 0.999) in the concentration range 0.02-10 microg/mL. Absolute recoveries of RST and IS were 85-110 and >100%, respectively, from rat plasma. The lower limit of quantification (LLOQ) of RST was 0.02 microg/mL. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.02, 0.06, 1.6 and 8.0 microg/mL, were in the range 7.24-12.43% relative standard deviation (RSD) and 2.28-10.23% RSD, respectively. Accuracy in the measurement of QC samples was in the range 93.05-112.17% of the spiked nominal values. Both analyte and IS were stable in the battery of stability studies, viz. benchtop, autosampler and freeze-thaw cycles. RST was found to be stable for a period of 30 days on storage at -80 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.  相似文献   

6.
A simple and sensitive high-performance liquid chromatography (HPLC) method has been developed and validated for the determination of DRF-1042, a novel orally active camptothecin (CPT) analog, in human plasma. The sample preparation was a simple deproteinization with acidified methanol yielding almost 100% recovery of DRF-1042. An isocratic reverse-phase HPLC separation was developed on a Supelcosil-LC318 column (250 x 4.6 mm, 5 microm) with mobile phase consisting of 1% v/v triethylamine acetate, pH 5.5 and acetonitrile (80:20, v/v) at a fl ow rate of 1.0 mL/min. The eluate was monitored with a fluorescence detector set at excitation and emission wavelengths of 370 and 430 nm, respectively. The standard curves were linear (r(2) > 0.999) in the concentration ranges 5.0-2004 ng/mL. The lower limit of quantification (LLQ) of the assay was 5 ng/mL. The mean measured quality control (QC) concentrations (range 5 ng/mL to 40 microg/mL) deviated from the nominal concentrations in the range of -10.5-0.08 and -14.5-7.97%, inter- and intra-day, respectively. The inter- and intra-day precisions in the measurement of QC samples at four tested concentrations, were in the range 0.64-5.89% relative standard deviation (RSD) and 0.33-14.7% RSD, respectively. The method was found to be suitable for measurement of plasma concentrations above the calibration curve after serial dilutions. Stability of DRF-1042 was confirmed in a battery of studies, viz., on bench-top, in the auto-sampler, in the stock solutions, after four quick freeze-thaw cycles, up to one month at -20 degree C in human plasma and up to 2 months in the ex vivo samples. The method is simple, sensitive and reliable and has been successfully implemented to investigate the clinical pharmacokinetics of DRF-1042 in cancer patients in a phase I clinical trial.  相似文献   

7.
A simple, accurate, precise, specific and reproducible high-performance liquid chromatography (HPLC) method was developed for simultaneous determination of resveratrol isomers in rat plasma. Cis-resveratrol was made by exposure of a trans-resveratrol solution to sunlight for 5 days followed by separation by HPLC and identification by mass spectrometry (MS). The assay procedure involved simple liquid-liquid extraction of resveratrol isomers and internal standard (IS, caffeine) from a small plasma volume directly into acetonitrile. The supernatant liquid was added an equal volume of water and injected onto a Hypersil ODS(2) C(18) column (5 microm, 4.6 x 250 mm). Mobile phase consisting of methanol and distilled water was used at a flow rate of 1.0 mL/min for the effective separation of cis-, trans-resveratrol and caffeine (IS). The detection of the analyte peak was achieved by monitoring the eluate using a UV detector set at 303 nm. The ratio of peak area of analyte to IS was used for quantification of plasma samples. Nominal retention times of cis-, trans-resveratrol and IS were 3.2, 4.3 and 6.1 min, respectively. The calibration curve was linear ranging from 0.066 to 6.64 and 0.134 to 13.4 microg/mL with correlation coefficients of 0.9998 and 0.9997 for trans and cis isomers, respectively. The absolute recovery of both isomers was more than 85%. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.066, 0.664 and 6.64 microg/mL of trans-resveratrol, were in the range 2.37-6.95% relative standard deviation (RSD) and 0.77-6.97% RSD, respectively. The inter- and intra-day precisions in the measurement of quality control (QC) samples, 0.134, 1.34 and 13.4 microg/mL of cis-resveratrol, were in the range 1.93-3.72% relative standard deviation (RSD) and 1.13-6.57% RSD, respectively. Both analytes and IS were stable in the battery of stability studies and freeze-thaw cycles. Resveratrol isomers were found to be stable for a period of 30 days on storage at -20 degrees C. The application of the assay to determine the pharmacokinetic disposition after a single oral dose to rats is described.  相似文献   

8.
A simple and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for determining rosuvastatin in human plasma, a new synthetic hydroxymethylglutaryl-coenzyme A reductase inhibitor. The analyte and internal standard (IS; cilostazol) were extracted by simple one-step liquid/liquid extraction with ether. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The chromatographic separation was performed on an Atlantis C18 column (2.1 mm x 150 mm, 5.0 microm) with a mobile phase consisting of 0.2% formic acid/methanol (30:70, v/v) at a flow rate of 0.20 mL/min. The analyses were carried out by multiple reaction monitoring (MRM) using the precursor-to-product combinations of m/z 482 --> 258 and m/z 370 --> 288. The areas of peaks from the analyte and the IS were used for quantification of rosuvastatin. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification (LLOQ) was 0.2 ng/mL and the assay exhibited a linear range of 0.2-50.0 ng/mL and gave a correlation coefficient (r) of 0.9991 or better. Quality control samples (0.4, 8, 25 and 40 ng/mL) in six replicates from three different runs of analysis demonstrated an intra-assay precision (RSD) 7.97-15.94%, an inter-assay precision 3.19-15.27%, and an overall accuracy (relative error) of < 3.7%. The method can be applied to pharmacokinetic or bioequivalence studies of rosuvastatin.  相似文献   

9.
A method for the simultaneous separation, identification, quantification and confirmation of the presence of 21 glucocorticoids (GCC) in equine plasma by liquid chromatography coupled with triple stage quadrupole tandem mass spectrometry (LC/TSQ-MS/MS) is described. Plasma sample augmented with the 21 GCC was extracted with methyl tert-butyl ether (MTBE) and analyzed by positive electrospray ionization. Desoxymetasone or dichlorisone acetate was used as the internal standard (IS). Quantification was performed by IS calibration. For each drug, one major product ion was chosen and used for screening for that drug. Analyte confirmation was performed by using the three most intense product ions formed from the precursor ion and the corresponding mass ratios. The recovery of the 21 GCC when spiked into blank plasma at 5 ng/mL was 45-200% with coefficient of variation (CV) from 0.3-18%. The limit of detection (LOD) and that of quantification (LOQ) for most of the analytes were 50-100 pg/mL and 1 ng/mL, respectively, whereas that of confirmation (LOC) was 100-300 pg/mL depending on the analyte. Intra- and inter-day precisions expressed as CV for quantification of 1 and 10 ng/mL was 1.0-17%, and 0.51-19%, respectively, and the accuracy was from 84-110%. The linear concentration range for quantification was 0.1-100 ng/mL (r(2) > 0.997). Estimated measurement uncertainty was from 11-37%. This study was undertaken to develop a method for simultaneous screening, identification, quantification and confirmation of these agents in post-race equine plasma samples. The method has been successfully applied to screening of a large number of plasma samples obtained from racehorses in competition and in pharmacokinetic studies of dexamethasone in the horse and concurrent changes in endogenous GCC, hydrocortisone and cortisone. The method is simple, sensitive, selective and reliably reproducible.  相似文献   

10.
A simple, sensitive and specific LC-MS/MS method for the determination of lipoic acid was developed and validated over the linearity range 5-1000 ng/mL (r2 > 0.99) with 200 microL rat plasma using rosigliatzone as an internal standard (IS). The assay procedure involved a simple one-step liquid-liquid extraction of lipoic acid and IS from plasma into ethyl acetate. The organic layer was separated and evaporated under a gentle stream of nitrogen at 40 degrees C. The residue was reconstituted in the mobile phase and injected onto a Hichrom RPB column (4.6 x 250 mm, 5 microm). Separation of lipoic acid and IS was achieved with a mobile phase consisting of 0.05 M formic acid:acetonitrile (40:60, v/v) at a flow rate of 1.0 mL/min. The API-3000 LC-MS/MS was operated under the multiple reaction monitoring mode (MRM) using the electrospray ionization technique. Positive and negative ion acquisition within the same chromatographic run was used in the present method. For lipoic acid a pseudo-molecular ion transition pair was acquired in negative polarity, whereas for IS the transition pair was acquired in positive polarity. Quantitation was determined for both analyte and IS in MRM scan mode. Absolute recovery of lipoic acid and IS was >70 and 97%, respectively. The lower limit of quantification (LLOQ) of lipoic acid was 5.0 ng/mL. The inter- and intra-day precision in the measurement of quality control (QC) samples 5, 15, 400 and 800 ng/mL were in the range 2.18-5.99% relative standard deviation (RSD) and 0.93-13.77% RSD, respectively. Accuracy in the measurement of QC samples was in the range 87.40-114.40% of the nominal values. Analyte and IS were stable in the battery of stability studies, viz. bench-top, auto-sampler and freeze-thaw cycles. Stability of lipoic acid was established for 1 month at -80 degrees C. The application of the assay to a pharmacokinetic study in rats confirmed the utility of the assay.  相似文献   

11.
A simple and sensitive liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of quercetin, kaempferol and isorhamnetin in rat plasma. After being treated with beta-glucuronidase and sulfatase, the analytes were extracted by liquid/liquid extraction with the internal standard (IS; baicalein). The chromatographic separation was performed on a Diamonsil C(18) column with a mobile phase consisting of 2% formic acid/methanol (10:90, v/v) at a flow rate of 1.00 mL/min, with a split of 200 microL to the mass spectrometer. Validation results indicated that the lower limit of quantification (LLOQ) was 1 ng . mL(-1). The assay exhibited a linear range of 1-200 ng . mL(-1) and gave a correlation coefficient of 0.9980 or better for each analyte. Quality control samples (1, 5, 20 and 100 ng . mL(-1)) in six replicates from each of three different runs demonstrated an intra-assay precision (RSD) of 1.1-8.9%, an inter-assay precision of 1.6-10.8%, and an overall accuracy (bias) of <13.4%. The extraction recovery of each analyte and internal standard was 70-80%. In the present study, we have investigated the pharmacokinetic profiles of isorhamnetin after oral application in rats equipped with a jugular catheter. After oral dosing of isorhamnetin, the mean values (n = 10) of C(max) were 57.8, 64.8 and 75.2 ng . mL(-1) which were achieved at a T(max) of 8.0, 6.4 and 7.2 h for oral doses of 0.25, 0.5 and 1.0 mg . kg(-1) body weight, respectively. The corresponding mean values for isorhamnetin area under the curver (AUC) from 0 to 60 h were 838.2, 1262.8, 1623.4 ng . h . mL(-1). Our results further demonstrated that the samples analyzed showed isorhamnetin could not be transformed into quercetin or kaempferol in rats, indicating that the demethylation of the 3'-oxymethyl group of isorhamnetin does not occur in Wistar rats.  相似文献   

12.
A sensitive, rapid and robust HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the quantification of sotalol in rat plasma. Plasma samples were precipitated with acetonitrile before analysis. The chromatographic separation was performed on an Atlantis hydrophilic interaction liquid chromatography Silica column (50 × 2.1 mm, 3 µm) with a gradient mobile phase of 10 mm NH4COOH (containing 0.2% of formic acid) as buffer A and acetonitrile as mobile phase B. Sotalol (m/z 273.2 → 255.1) and atenolol (the internal standard, IS, m/z 267.2 → 190.1) were monitored under positive ionization mode with 5500 QTRAP. Retention time of sotalol and the IS were 2.69 and 3.43 min, respectively. The linear range was 5–500 nm based on the analysis of 0.1 mL of plasma. The intrabatch precision ranged from 1.2 to 6.1%, and the inter‐batch precision was from 3.3 to 6.5%. The coefficient of variation of IS‐normalized matrix factor was 7.6%. Experiments for stability were performed and the analyte was sufficiently stable. A run time of 6 min for each injection made it possible to analyze a high throughput of plasma samples. The assay was successfully applied to the determination of sotalol in rat plasma after a micro‐dose oral administration. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
A simple, sensitive, selective and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of atorvastatin and its active metabolites ortho-hydroxyatorvastatin and para-hydroxyatorvastatin in human plasma using rosuvastatin as internal standard (IS). Following simple liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 559/440 for atorvastatin, m/z 575/466 for ortho-hydroxyatorvastatin, m/z 575/440 for para-hydroxyatorvastatin and m/z 482/258 for the IS. The assay exhibited a linear dynamic range of 0.1-20 ng/mL for atorvastatin and its two metabolites in human plasma. The lower limit of quantification was 100 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of atorvastatin, ortho-hydroxyatorvastatin, para-hydroxyatorvastatin and the IS from spiked plasma samples were 54.2 +/- 3.2, 50.1 +/- 3.8, 65.2 +/- 3.6 and 71.7 +/- 2.7%, respectively. A run time of 2.5 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.  相似文献   

14.
In order to research the pharmacokinetics of salvianolic acid A (SalA), a herbal ingredient isolated from Salvia miltiorrhiza Bunge, after intravenous administration to rats, a specific and accurate high-performance liquid chromatography (HPLC) was developed. The assay procedure involved simple liquid-liquid extraction of SalA and internal standard (IS, ethyl-p-hydroxybenzoate) from plasma into ethyl acetate. The organic layer was separated and evaporated under reduced pressure at 40 degrees C. The residue was reconstituted in the mobile phase and analyzed on an Inertsil C8 column, monitored at 285 nm. The mobile phase, which consisted of methanol-acetonitrile-water-formic acid (10:20:70:0.4, by vol), was used at a flow rate of 1.0 mL/min. The ratio of the peak area of the analyte to IS was applied to quantify the plasma samples. The standard curve for SalA was linear (r2 = 0.9999) in the concentration range of 0.75-150 microg/mL. The limit of quantitation (LOQ) of SalA was 0.75 microg/mL. The intra- and inter-day precisions (RSD) of the quality control (QC) samples were in the ranges of 2.17-3.29 and 1.24-5.28%, respectively. Accuracy in the measurement of QC samples ranged from 94.7 to 101.1%. This method was validated for specificity, accuracy and precision and was successfully applied to the pharmacokinetic study of SalA in rat plasma after intravenous administration of Danshen injection.  相似文献   

15.
7-Ethyl-10-hydroxycamptothecin (SN-38) is an active metabolite of Irinotecan (CPT-11), an anticancer pro-drug. To support clinical pharmacokinetic studies for liposome based formulation of SN-38 (LE-SN38) in cancer patients, a rapid, simple and sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantification of total SN-38 in human plasma. Sample preparation was carried out by one-step protein precipitation using cold acetonitrile with 0.5% acetic acid (v/v). Camptothecin was used as an internal standard (IS). Chromatographic separation of SN-38 and IS was achieved using a Synergi Hydro-RP column (C(18), 50 x 2 mm, 4 micro m), with a gradient elution of acetonitrile and 0.1% acetic acid. After ionization in electrospray source (positive ions), the acquisition was performed in the multiple reactions monitoring mode. Quantitation was accomplished using the precursor-->product ion combinations of m/z 393.1-->349.2 for SN-38 and 349.1-->305.1 for IS. The quantification limit of 0.05 ng/mL was achieved by using much lower volume (0.2 mL) of plasma and in the presence of LE-SN38. The method was validated over the concentration range of 0.05-400 ng/mL. Accuracy was within +/-12% of nominal at all concentration levels. Inter-day and intra-day precisions expressed as percentage coefficient of variation (%CVs) for quality control (QC) samples were less than 14 and 5%, respectively.  相似文献   

16.
A rapid, sensitive and selective liquid chromatography-tandem spectrometry method was developed and validated for determination of paeoniflorin in rat plasma using geniposide as the internal standard. The samples were pretreated with solid-phase extraction using Extract-Clean cartridges. Separation of paeoniflorin and IS was achieved on a reversed-phase C18 column (50x4.6 mm i.d.) with a mobile phase made up of acetonitrile and 0.05% formic acid (25:75, v/v) at a flow rate of 0.5 mL/min. Detection was carried out on a triple quadrupole tandem mass spectrometer by multiple-reaction monitoring and an electrospray ionization source was employed as the ionization source. The lower limit of quantification obtained was 4 ng/mL (n=6) using 200 microL plasma with an accuracy of -3.67% (relative error) and a precision of 4.13% (relative standard deviation). A good linearity was found in the range of 4-1000 ng/mL. The intra- and inter-day relative standard deviations in the measurement of quality control samples 10, 150 and 800 ng/mL ranged from 3.73 to 4.94% and from 4.31 to 6.56%, respectively. The accuracy was from -3.93 to -1.11% in terms of relative error. The analyte and IS were stable in the battery of stability studies. This method was successfully applied to a pharmacokinetic study of paeoniflorin after a single oral administration of 53.36 mg/kg paeoniflorin to rats.  相似文献   

17.
In order to evaluate the pharmacokinetic (PK) profile of rabeprazole (RA) sterile powder for injection, a rapid, sensitive and specific assay for quantitative determination of RA in dog plasma was developed and validated. After a liquid-liquid extraction procedure, samples were analyzed by liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS) using omepazole as the internal standard (IS). The analyte and IS was chromatographed on a ZORBAX Extend-C(18) analytical column (50 x 2 mm i.d, 5 microm, Agilent Technologies, USA). The assay was linear in the range 1-2000 ng/mL. The lower limit of quantification of RA was 1 ng/mL. The recovery of RA was greater than 70%. The within- and between-batch accuracy was 102.7-107.4% and 103.5-105.7%, respectively. The plasma samples for the PK study were collected at defined time points during and after an intravenous injection (1 mg/kg) to beagle dogs and analyzed by LC-ESI-MS method. The PK parameters, such as half-life, volume of distribution, total clearance and elimination rate constant, were determined. The PK profile of RA gave insights into the application in the clinics.  相似文献   

18.
A simple, sensitive and specific high-performance liquid chromatography method is described for simultaneous determination of rosuvastatin (RST) and gemfibrozil (GFZ) in human plasma using celecoxib as an internal standard (IS). The assay procedure involved extraction of RST, GFZ and IS from plasma into acetonitrile. Following separation and evaporation of the organic layer the residue was reconstituted in the mobile phase and injected onto an X-Terra C(18) column (4.6 x 150 mm, 5.0 microm). The chromatographic run time was less than 20 min using flow gradient (0.0-1.60 mL/min) with a mobile phase consisting of 0.01 M ammonium acetate:acetonitrile:methanol (50:40:10, v/v/v) and UV detection at 275 nm. Nominal retention times of RST, GFZ and IS were 6.7, 13.9 and 16.4 min, respectively. Absolute recovery of both analytes and IS was greater than 90%. The lower limit of quantification (LLOQ) of RST and GFZ was 0.03 and 0.30 microg/mL, respectively. Linearity was excellent (r(2) = 0.999) in the 0.03-10 microg/mL and 0.3-100 microg/mL ranges for RST and GFZ, respectively. The inter- and intra-day precisions in the measurement of RST quality control (QC) samples 0.03, 0.09, 2.50 and 8.00 microg/mL were in the range 2.37-9.78% relative standard deviation (RSD) and 0.92-10.08% RSD, respectively. Similarly, the inter- and intra-day precisions in the measurement of GFZ quality control (QC) samples 0.30, 0.90, 25.0 and 80.0 microg/mL were in the ranges 2.79-6.27 and 0.96-9.69% RSD, respectively. Accuracies in the measurement of QC samples for RST and GFZ were in the range 85.43-107.23 and 84.98-102.35% respectively, of the nominal values. RST and GFZ were stable in the array of stability studies viz., bench-top, auto-sampler and freeze-thaw cycles. Stability of RST and GFZ was established for 1 month at -80C. The application of the assay in an oral pharmacokinetic study in rats co-administered with RST and GFZ is described.  相似文献   

19.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

20.
A simple, sensitive and rapid liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) method was developed and validated for the quantification of valproic acid, an antiepileptic drug, in human plasma using benzoic acid as internal standard (IS). Following solid-phase extraction, the analytes were separated using an isocratic mobile phase on a reversed-phase C18 column and analyzed by MS in the single ion monitoring mode using the respective [M-H]- ions, m/z 143 for valproic acid and m/z 121 for the IS. The assay exhibited a linear dynamic range of 0.5-60 microg/mL for valproic acid in human plasma. The lower limit of quantification was 500 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of valproic acid and the IS from spiked plasma samples were 96.1+/-4.2 and 95.6+/-2.7%, respectively. A run time of 4.5 min for each sample made it possible to analyze more than 250 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability and bioequivalence studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号