首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Savings in analysis time in capillary GC have always been an important issue for chromatographers since the introduction of capillary columns by Golay in 1958. In laboratories where gas chromatographic techniques are routinely applied as an analytical technique, every reduction of analysis time, without significant loss of resolution, can be translated into a higher sample throughput and hence reduce the laboratory operating costs. In this contribution, three different approaches for obtaining fast GC separations are investigated. First, a narrow-bore column is used under conventional GC operating conditions. Secondly, the same narrow-bore column is used under typical fast GC conditions. Here, a high oven temperature programming rate is used. The third approach uses a recent new development in GC instrumentation: Flash-2D-GC. Here the column is placed inside a metal tube, which is resistively heated. With this system, a temperature programming rate of 100°/s is possible. The results obtained with each of these three approaches are compared with results obtained on a column with conventional dimensions. This comparison takes retention times as well as plate numbers and resolution into consideration.  相似文献   

2.
The use of hot splitless, cold splitless, and on-column injections for trace analysis in narrow-bore capillary GC is evaluated. Despite the low flow rates for the columns used, the required splitless times for splitless injections can be surprisingly short if liners with a small inside diameter are used. On-column injection can be applied by using an appropriate normal-bore precolumn coupled to the narrow-bore analytical column using a specially designed low dead volume column connector. The effects of the experimental conditions such as sample volume, injection temperature, and initial oven temperature on peak focusing and the discrimination and degradation behavior of the analytes are discussed. The possibilities to obtain sensitive and fast separations are illustrated by various applications.  相似文献   

3.
Short capillary columns (5 m) with 0.25 mm inner diameter (I.D.) are applied to the GC analysis of medium complexity samples (up to 30 components) with the aim of shortening analysis time. This approach is complementary to fast GC with narrow-bore columns and is based on compensating the lower efficiency of short columns with conventional I.D.'s (0.25-0.32 mm) by using a stationary phase selectivity suitable to separate the components of the sample under investigation, so that the required resolution power is achieved but, at the same time, the analysis time is shortened. The qualitative and quantitative effectiveness of this approach is demonstrated through the analysis of: essential oils with different compositions (chamomile and rosemary), low-volatility triterpenes in a plant extract (Maytenus aquifolium and M. ilicfolium), thermolabile pyrethrins in a Pyrethrum extract, and a mixture of pesticides applied to protect medicinal plant crops. In all examples, GC analysis was five to ten times faster than with conventional columns.  相似文献   

4.
Packed capillary column solvating gas chromatography (SGC) and open tubular column gas chromatography (GC) were compared with respect to their potentials for fast separations. A recently introduced "universal" peak capacity equation was used to compare the performance of these two methods. The effects of various factors on peak capacity were investigated. Results demonstrate that retention factor and column efficiency are the main factors affecting peak capacity for fast separations. Packed columns produce both high retention factors and high selectivities. While high efficiencies and high peak capacities can be demonstrated by both techniques, open tubular column GC can surpass packed capillary column SGC in both measurements, except for the case of the analysis of simple mixtures in short analysis times, where retention factor and selectivity become important. Practical aspects such as pressure drop and sample capacity are compared for SGC and open tubular column GC. It was found that packed column SGC demonstrates higher sample capacities, but requires much higher column inlet pressures than open tubular column GC. A variety of mobile phases can be used for packed column SGC, which can provide high solvating power for large and polar compounds.  相似文献   

5.
Summary Electrochromatography (that is HPLC where the eluent is driven along the column by electro-osmosis using fields of up to 100 kV m−1) promises plate efficiencies for HPLC which are comparable to those attained in capillary gas chromatography, but this requires that narrow-bore columns can be successfully packed with submicron particles. This paper demonstrates that we have now moved a considerable distance towards this goal. We show (1) that, following theory, there is no evidence of any reduction in electroosmotic velocity in columns packed with particles down to 1.5 μm diameter, (2) that reduced plate heights as low as unity are attainable for unretained solutes using both slurrypacked and drawn-packed columns 30 to 200 μm bore and up to 1 m long when packed with conventional 3 and 5 μm silica gels or with 1.5 μm impermeable silica spheres, (3) that columns driven electrically show higher plate efficiencies than identical columns driven by pressure, and (4) that 100,000 plate HPLC separations can be achieved in relatively short times of 30 minutes using in situ derivatised drawn packed capillaries containing 3 and 5 μm ODS-silica gels.  相似文献   

6.
For clinical and environmental analyses utilizing capillary gas chromatography/mass spectrometry (GC/MS), increased sensitivity and speed of analysis are highly desirable. These performance advantages are realized using a WCOT column of 100 μm i.d. as compared to the more conventional 200 μm i.d. capillary columns. The improved sensitivity of capillary direct GC/MS with the 100 μm i.d. column for the confirmation of drugs of abuse will be demonstrated. For environmental analysis, the superior efficiency and resolution of the 100 μm i.d. column can be employed for the separation of priority pollutants. This approach is more amenable to capillary direct GC/MS providing a more effective interface to the mass spectrometer. As a result improved sensitivity and a considerable decrease in analysis time is achieved over that obtained with the larger diameter environmental specialty phase columns.  相似文献   

7.
字敏  张玉海  艾萍  袁黎明 《化学通报》2006,69(10):793-796
以纤维素三苯甲酸酯、纤维素三苯基氨基甲酸酯以及二者的混合物为固定相,制备了新型毛细管气相色谱柱,最高柱效达到2580板/米。其能对一些难分离物质对、位置异构体以及手性化合物进行拆分,如对丙氨酸的分离因子可达到1·13。此外,还研究了毛细管柱的极性、选择性以及保留机理。结果表明,该类聚合物是一类很有前景的新型气相色谱固定相。  相似文献   

8.
The relationship between analysis time and separation with glass capillary columns was studied. Optimal operating parameters for achieving the shortest analysis times consistent with degree of separation were determined experimentally. It was found that the optimum column temperature is governed by retention characteristics of the solutes and the optimum column length by the required magnitude of separation. The optimum carrier gas flow-rate was found to be a function of the column length. Emphasis is placed on using capillary column length as an operating parameter.  相似文献   

9.
A method for the rapid trace analysis of 17 residual pesticides in water by narrow-bore capillary (I.D. 100 microm) gas chromatography-mass spectrometry (GC-MS) using a programmable temperature vaporizer (PTV) was discussed. The method consisted of a large-volume injection (40 microl) by a PTV, high-speed analysis using a narrow-bore capillary column and MS detection. The PTV with solvent vent mode was very useful for large-volume injection into a narrow-bore capillary column because the injected solvent volume could be reduced to less than 2 microl. The analysis time was 8.5 min [less than 50% of the analysis time using conventional columns (I.D. 250 microm)]. A 10-ml volume of river water was extracted by dichloromethane (4 ml), and then the extract was condensed to 1 ml. This extract was analyzed. Mean recoveries for river water spiked at 100 pg/ml ranged from 83.4 to 96.7%. The limit of detections of the 17 pesticides ranged from 1 to 100 pg/ml.  相似文献   

10.
快速气相色谱法分析石油饱和烃   总被引:6,自引:0,他引:6  
武杰  曹磊  李英明  端裕树 《色谱》2004,22(5):479-481
提出了一种快速分析原油和岩石抽提物中饱和烃组分的毛细管气相色谱(GC)方法。由于在该方法中采用了细内径毛细管柱,故饱和烃的GC分析周期由原来的80~90 min缩短至15 min,分析速度加快约5倍,大大提高了工作效率和仪器通量,使石油饱和烃得到了很好的分离分析。该方法符合中华人民共和国石油天然气行业标准SY/T5120-1997的要求。20万理论塔板数的细径柱的应用,可供石油中异构烷烃,尤其是甾烷、萜烷类的气相色谱/质谱(GC/MS)快速分析方法及芳烃的GC快速分析方法借鉴。  相似文献   

11.
Guiochon G 《Journal of chromatography. A》2007,1168(1-2):101-68; discussion 100
Monolithic media have been used for various niche applications in gas or liquid chromatography for a long time. Only recently did they acquire a major importance in high-performance column liquid chromatography (HPLC). The advent of monolithic silica standard- and narrow-bore columns and of several families of polymer-based monolithic columns has considerably changed the HPLC field, particularly in the area of narrow-bore columns. The origin of the concept, the differences between their characteristics and those of traditional packed columns, their advantages and drawbacks, the methods of preparation of monoliths of different forms, and the current status of the field are reviewed. The actual and potential performance of monolithic columns are compared with those of packed columns. Monolithic columns have considerable advantages, which makes them most useful in many applications of liquid chromatography. They are extremely permeable and offer a high efficiency that decreases slowly with increasing flow velocity.  相似文献   

12.
Four mega-bore, one wide-bore, and one narrow-bore fused-silica capillary columns were evaluated for their applicability to the GC/ECD analysis of 22 chlorinated hydrocarbons, some of which are currently targeted by EPA Method 8120. No one column can resolve all 22 compounds investigated here. Four compounds (two pairs) are coeluting on the SPB-35, DB-210, DB-WAX, and DB-519 fused-silica capillary columns, five compounds (two groups) are coeluting on the DB-1301 fused-silica capillary column, and ten compounds (five pairs) are coeluting on the SPB-5 fused-silica capillary column. The analysis time varies between 30 and 50 min. The order of elution of the chlorinated benzenes seems to depend on their boiling points rather than on the polarity of the liquid phase. The retention times of an additional nine chlorinated toluenes, eight chlorinated xylenes, and five chlorinated naphthalenes are also reported. Electron capture detector linearity is reported for the DB-210 fused-silica capillary column. Five brominated compounds were investigated as possible internal standards for Method 8120.  相似文献   

13.
Summary Room temperature ionic liquids (RTIL) are molten salts with melting points well below room temperature. 1-butyl-3-methylimidazolium chloride is a typical example of such RTIL. It was used as a solvent to dissolve permethylated-β-cyclodextrin (BPM) and dimethylated-?cyclodextrin (BDM) to prepare stationary phases for capillary columns in gas chromatography for chiral separation. The RTIL containing columns were compared to commercial columns containing the same chiral selectors. A set of 64 chiral compounds separated by the commercial BPM column was tested on the RTIL BPM column. Only 21 were enantioresolved. Similarly, a set of 80 compounds separated by the commercial BDM column was passed on the RTIL BDM column with only 16 positive separations. It is proposed that the imidazolium ion pair could make an inclusion complex with the cyclodextrin cavity, blocking it for chiral recognition. All the chiral compounds recognized by the RTIL columns had their asymmetric carbon that was part of a ring structure. The retention factors of the derivatized solutes were lower on the RTIL columns than those obtained on the commercial equivalent column. The peak efficiencies obtained with the RTIL capillary were significantly higher than that obtained with the commercial column. These observations may contribute to the knowledge of the mechanism of cyclodextrin-based GC enantioselective separations.  相似文献   

14.
张才华  孙菁  聂崇实 《化学学报》1989,47(4):389-392
本文介绍毛细管GC/IR方法鉴定a-蒎烯在固体酸Nafion H催化下酯化及重排异构化的产物. 讨论了GC/IR方法定性的可靠性及存在的问题, 并对GC/IR实验方法, 作了较为详细的研究, 其中包括不同口经毛细管色谱柱与光管匹配问题和影响红外检测灵敏度的多种因素.  相似文献   

15.
The writer of this review published in 1978 a three-part article on two-dimensional gas chromatography in the first three issues of this journal [1]. The review was written at a time when capillary column GC was still in its infancy. Commercial columns were (essentially) unavailable and sample introduction into capillary columns was done exclusively in the split mode. Two-dimensional separations were explored in only a few laboratories. The limitations of capillary column technology made this exercise rather difficult. The introduction of fused silica capillary columns in the early eighties drastically changed the landscape in which gas chromatography was practiced. It took the chromatographic community just a few years to convert from packed columns to capillary columns. Instrumentation and accessories specifically designed for capillary column use came onto the market. This writer had great hopes that the revolution in capillary column GC would be mirrored in the development of instrumentation for Two-Dimensional Gas Chromatography. This never materialized. On the contrary, tentative steps taken by a few manufacturers and suppliers of chromatographic equipment fizzled out. It was perhaps the introduction of relatively inexpensive and user friendly GC/MS instrumentation, in combination with nearly indestructible fused silica capillary columns that took away the incentive to develop commercially viable Two-Dimensional Gas Chromatography. Much of the thinking went like this: why insist on good chromatography if mass spectrometry can do the job without the need for complete separation. Some progress in the further development of conventional Two-Dimensional Gas Chromatography has certainly been made over the last 20 years but there has not been a great deal of excitement. Applications have also been relatively sparse and they are limited to just a few areas. Science does not remain static and chromatography is no exception. Progress in gas chromatography is driven by new technology and ideas. Substantial improvements in two-dimensional GC were not forthcoming until Phillips and his research group introduced and implemented an entirely new form of Two-Dimensional Gas Chromatography, called comprehensive two-dimensional GC, or GC×GC. This breakthrough occurred only in 1991 [2]. It does take some time before scientists change attitudes and habits. There is always a time lag between the introduction of new technology and its general acceptance. The public's attitude toward comprehensive Two-Dimensional Gas Chromatography is probably no exception. The number of scientists who are actively pursuing this new branch of gas chromatography is still very small. It is often a single individual who carries the torch. J.B. Phillips' name is synonymous with comprehensive Two-Dimensional Gas Chromatography. He is not only its inventor and proponent but his fertile mind has initiated research in other related areas. Sadly, he passed away shortly before this review was written. This contribution is dedicated to his memory.  相似文献   

16.
Supercritical fluid chromatography of carbohydrates   总被引:1,自引:0,他引:1  
Supercritical fluid chromatography (SFC) is a relatively new technique applied to polar solutes such as carbohydrates about 10 years ago. The developments in the SFC of carbohydrates are summarized and a comparison between capillary and packed column SFC is presented. High-efficiency capillary columns are suitable only for derivatized carbohydrates since various packed columns are well adapted for non derivatized mono-, di- and trisaccharides and provide complementary selectivities.  相似文献   

17.
Summary Packed columns containing microparticles provide high column efficiency per unit time and strong retention characteristics compared with open tubular columns, and they are favored for fast separations. Nonporous particles eliminate the contribution of solute mass transfer resistance in the intraparticle void volume characteristic of porous particles, and they should be more suitable for fast separations. In this paper, the evaluation of nonporous silica particles of sizes ranging from 5 to 25 μm in packed capillary columns for fast supercritical fluid chromatography (SFC) using neat CO2 is reported. These particles were first deactivated using polymethyl-hydrosiloxanes and then encapsulated with a methylphenylpolysiloxane stationary phase. The retention factors, column efficiencies, column efficiencies per unit time, separation resolution, and separation resolution per unit time for fast SFC were determined for various length capillaries packed with various sizes of polymerencapsulated nonporous particles. It was found that 15 μm nonporous particles provided the highest column efficiency per unit time and resolution per unit time for fast packed capillary SFC. Under certain conditions, separations were completed in less than 1 min. Several thermally labile silylation reagent samples were separated in times less than 5 min. Presented at the 21st ISC held in Stuttgart, Germany, 15th–20th September, 1996  相似文献   

18.
Small columns packed with core-shell and sub-2 μm totally porous particles and monolith columns are very popular to conduct fast and efficient chromatographic separations. In order to carry out fast separations, short (2-5 cm) and narrow-bore (2-2.1 mm) columns are used to decrease the analyte retention volume. Beside the column efficiency, another significant issue is the extra-column band-spreading. The extra-column dispersion of a given LC system can dramatically decrease the performance of a small very efficient column. The aim of this study was to compare the extra-column peak variance contribution of several commercially available LC systems. The efficiency loss of three different type 5 cm long narrow bore, very efficient columns (monolith, sub-2 μm fully porous and sub-2 μm core-shell packing) as a function of extra-column peak variance, and as a function of flow rate and also kinetic plots (analysis time versus apparent column efficiency) are presented.  相似文献   

19.
Glass capillary gas chromatography is a high resolution separation method which allows the qualitative and quantitative analysis of even complex mixtures, which may contain many components–also isomeric–in a wide range of volatilities, polarities and concentrations. The principal limitation of gas chromatographic application is given by an insufficient volatility of the species to be separated. Elevated temperatures have to be applied if the application range is to be extended and to achieve steep peak profiles, i.e. low detection limits at high resolution. The use of elevated temperatures is limited, of course, by the temperature stability of both the solvent (stationary liquid and support) and the solutes. The problems of trace analysis for low volatility compounds at high resolution and its limitational parameters regarding sampling, separation and detection are discussed. The applicability of glass capillary columns in this field is influenced by the following parameters: tailing behaviour; irreversible adsorption of polar and decomposition of unstable solutes; thermal stability of stationary liquid (including the support deactivation); separation efficiency and sample capacity (film thickness). Multidimensional gas chromatography using capillary columns coupled either with a packed or another capilllary column for preseparations may be applied with advantage in the analysis of complex mixtures.  相似文献   

20.
Monolithic columns invented in chromatographic praxis almost 40 years ago gained nowadays a lot of popularity in separations by liquid chromatographic technique. At the same time, application of monolithic columns in gas chromatography is less common and only a single review published by Svec et al. [1] covers this field of research. Since that time a lot of new findings on application and properties of monolithic columns in gas chromatography have been published in the literature deserving consideration and discussion. This review considers preparation of monolithic columns for GC, an impact of preparation conditions on column performance, optimization of separation conditions for GC analysis on monolithic columns and other important aspects of preparation and usage of monolithic capillary columns in GC. A final part of the review discusses the modern trends and possible applications in the future of capillary monolithic columns in GC.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏