 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sung WC  Makamba H  Chen SH 《Electrophoresis》2005,26(9):1783-1791
We present the current status of the development of microfluidic devices fabricated on different substrates for coupling with electrospray ionization-mass spectrometry (ESI-MS). Until now, much success has been gained in fabricating the ESI chips, which show better performances due to miniaturization when compared with traditional methods. Integration of multiple steps for sample preparation and ESI sample introduction, however, remains a great challenge. This review covers the main technical development of electrospray device that were published from 1997 to 2004. This article does not attempt to be exclusive. Instead, it focuses on the publications that illustrated the breath of the development and applications of microchip devices for MS-based analysis.  相似文献   

2.
A novel microfabricated device for isoelectric focusing (IEF) incorporating an optimized electrospray ionization (ESI) tip was constructed on polycarbonate plates using laser micromachining. The IEF microchip incorporated a separation channel (50 micro x 30 micro x 16 cm), three fluid connectors, and two buffer reservoirs. Electrical potentials used for IEF focusing and electrospray were applied through platinum electrodes placed in the buffer reservoirs, which were isolated from the separation channel by porous membranes. Direct ESI-mass spectrometry (MS) using electrosprays produced directly from a sharp emitter "tip" on the microchip was evaluated. The results indicated that this design can produce a stable electrospray and that performance was further improved and made more flexible with the assistance of a sheath gas and sheath liquid. Error analysis of the spectral data showed that the standard deviation in signal intensity for an analyte peak was less than approximately 5% over 3 h. The production of stable electrosprays directly from microchip IEF device represents a step towards easily fabricated microanalytical devices. Microchannel IEF separations of protein mixtures were demonstrated for uncoated polycarbonate microchips. Direct microchannel IEF-ESI-MS was demonstrated using the microfabricated chip with an ion-trap mass spectrometer for characterization of protein mixtures.  相似文献   

3.
电泳微芯片由于具有自动化程度高、试剂消耗少和分析速度快等优点,目前已经成为微全分析系统研究的热点.  相似文献   

4.
This study presents coupling of a poly(dimethylsiloxane) (PDMS) micro-chip with electrospray ionization-mass spectrometry (ESI-MS). Stable electrospray is generated directly from a PDMS micro-channel without pressure assistance. Hydrophobic PDMS aids the formation of a small Taylor cone in the ESI process and facilitates straightforward and low-cost batch production of the ESI-MS chips. PDMS chips were replicated with masters fabricated from SU-8 negative photoresist. A novel coating, an amorphous diamond-like carbon-poly(dimethylsiloxane) hybrid, deposited on the masters by the filtered pulsed plasma arc discharge technique, improved significantly the lifetime of the masters in PDMS replications. PDMS chip fabrication conditions were observed to affect the amount of background peaks in the MS spectra. With an optimized fabrication process (PDMS curing agent/silicone elastomer base ratio of 1/8 (w/w), curing at 70 degree C for 48 h) low background spectra were recorded for the analytes. The performance of PDMS devices was examined in the ESI-MS analysis of some pharmaceutical compounds and amino acids.  相似文献   

5.
The design, fabrication, and analytical use of a poly(methylmethacrylate) (PMMA)-based microfluidic module for nanoelectrospray ionization-tandem mass spectrometry (nano-ESI-MS/MS) were described. The microfluidic module can be mass-produced at low costs and used as a disposable device to generate nano-ESI-MS/MS signals for protein identification from low amounts of protein samples. Compared with commercially available nanospray capillary tips, the module gave comparable signal quality and also offered advantages in convenience and easiness of operation, permitting repeated usage, and disposability.  相似文献   

6.
A polymer microchip with an open tip for electrospray mass spectrometry is presented. The tip consists of a groove with parallel walls where a droplet can form at the end surface. A lid covers the whole chip except at the microchannel tip, which is left open. Poly(dimethylsiloxane) (PDMS) microchips were cast using a nickel mould which in turn was replicated from a dry etched silicon wafer. Tips with microchannel widths of around 50 microm could easily be replicated. Since the tip had no cover, the assembly of microchip and cover was simplified. A total ion current variation of 5% during 300 s was achieved for a 1 microM myoglobin solution. The non-complex design of the cover makes it suitable for versatile tests of chip prototypes. The nickel mould was found to be useful for PDMS microstructure fabrication. Also, such a robust mould allows casting electrospray tips in more rigid thermoset materials.  相似文献   

7.
Recently, the development of electrochemical biosensors as part of microfluidic devices has garnered a great deal of attention because of the small instrument size and portability afforded by the integration of electrochemistry in microfluidic systems. Electrode fabrication, however, has proven to be a major obstacle in the field. Here, an alternative method to create integrated, low cost, robust, patternable carbon paste electrodes (CPEs) for microfluidic devices is presented. The new CPEs are composed of graphite powder and a binder consisting of a mixture of poly(dimethylsiloxane) (PDMS) and mineral oil. The electrodes are made by filling channels molded in previously cross-linked PDMS using a method analogous to screen printing. The optimal binder composition was investigated to obtain electrodes that were physically robust and performed well electrochemically. After studying the basic electrochemistry, the PDMS-oil CPEs were modified with multi-walled carbon nanotubes (MWCNT) and cobalt phthalocyanine (CoPC) for the detection of catecholamines and thiols, respectively, to demonstrate the ease of electrode chemical modification. Significant improvement of analyte signal detection was observed from both types of modified CPEs. A nearly 2-fold improvement in the electrochemical signal for 100 μM dithiothreitol (DTT) was observed when using a CoPC modified electrode (4.0 ± 0.2 nA (n = 3) versus 2.5 ± 0.2 nA (n = 3)). The improvement in signal was even more pronounced when looking at catecholamines, namely dopamine, using MWCNT modified CPEs. In this case, an order of magnitude improvement in limit of detection was observed for dopamine when using the MWCNT modified CPEs (50 nM versus 500 nM). CoPC modified CPEs were successfully used to detect thiols in red blood cell lysate while MWCNT modified CPEs were used to monitor temporal changes in catecholamine release from PC12 cells following stimulation with potassium.  相似文献   

8.
We present the design and performance of an in-house built electrospray ionization-mass spectrometry (ESI-MS) interface equipped with an S-lens ion guide. The ion source was designed specifically for our ion beam experiments to investigate the chemical reactivity and deposition of the clusters and nanoparticles. It includes standard ESI-MS interface components, such as nanoelectrospray, ion transfer capillary, and the S-lens. A custom design enables systematic optimization of all relevant factors influencing ion formation and transfer through the interface. By varying the ESI voltage and flow rate, we determined the optimal operating conditions for selected silica emitters. A comparison of the pulled silica emitters with different tip inner diameters reveals that the total ion current is highest for the largest tip, whereas a tip with the smallest diameter exhibited the highest transmission efficiency through the ESI-MS interface. Ion transmission through the transfer capillary is strongly limited by its length, but the loss of ions can be reduced by increasing the capillary voltage and temperature. The S-lens was characterized over a wide range of RF frequencies and amplitudes. Maximum ion current was detected at RF amplitudes greater than 50 V peak-to-peak (p/p) and frequencies above 750 kHz, with a stable ion transmission region of about 20%. A factor of 2.6 increase in total ion current is observed for 650 kHz as RF amplitudes reach 400 V p/p. Higher RF amplitudes also focus the ions into a narrow beam, which mitigates their losses when passing through the ion guide.  相似文献   

9.
A peptide separation strategy that combines two-dimensional (2-D) liquid chromatography (LC)-capillary zone electrophoresis (CZE) with tandem mass spectrometry (MS/MS) is described for the identification of proteins in complex mixtures. To test the effectiveness of this strategy, a serum sample was depleted of the high-abundance proteins by methanol precipitation, digested with trypsin to generate a complex peptide mixture, and separated into 96 fractions by reversed-phase (RP)-LC. Compared to ion-exchange LC separations, RPLC provides much higher resolution and peak capacity. Fractions were collected off-line from the RPLC separation, and subjected to short 20 min CZE separations. The separated zones were introduced to the mass spectrometer through a sheathless electrospray ionization interface that is integrated on the separation capillary. The ease of fabrication of the interface and its durability allowed for the analysis of all fractions on a single capillary in a relatively short analysis time. A stable electrospray was produced at nanoliter flowrates by augmenting analyte electrophoretic and electroosmotic mobilities with pressure-assisted flow. Unlike first-dimensional ion-exchange LC fractionation, where there is a large degree of overlap, the CZE-MS results show less than 15% overlap between neighboring RPLC fractions.  相似文献   

10.
J S Kim  D R Knapp 《Electrophoresis》2001,22(18):3993-3999
A multichannel electrospray ionization (ESI) emitter was fabricated as part of a poly(dimethylsiloxane) (PDMS) microfluidic device using a three-layer photoresist process which also produces a self-alignment system to make a bonding between the top and bottom PDMS parts. The prototype device (2 cm high x 5 cm wide x 5 cm long) had 16-channels (30 microm wide x 50 microm deep) with emitters of 1 mm length and 60 degrees point angle. The PDMS emitter tips enabled interfacing the device to ESI-mass spectrometry; a stable electrospray from the tips was performed with limits of detection under 1 microM for reference peptides (adrenocorticotropic hormone fragment 1-17, angiotensin I and III).  相似文献   

11.
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the direct analysis of liquid samples. Several interesting results were found. First, in contrast to the previous DESI analysis of dried solid samples that was limited to proteins with MW ≤25 kDa (Anal. Chem. 2007, 79, 3514), bovine serum albumin (BSA, 66 kDa) was successfully ionized from solutions by DESI with observation of corresponding multiply charged ions. Second, direct DESI analysis of protein tryptic digest solutions without chromatographic separation, sample clean-up, and the sample drying step was demonstrated, providing reasonably good sequence coverage of 52% to 97%. Third, direct analysis of biofluids such as an undiluted urine sample without sample pretreatment is possible, emphasizing the high tolerance of DESI with salt. These results suggest that a charged droplet pick-up mechanism is responsible for desorption and ionization of liquid samples by DESI. Also, unlike in electrospray ionization (ESI), inhibition of electrochemical reduction in the negative ion mode was observed for liquid sample DESI. In addition, reactive DESI can be performed with ion/ion reactions of Zn(II) complexes for the selective binding of phosphoserine in the presence of serine. DESI experiment can also be carried out directly to liquid samples flowing out of a pumped syringe needle tip, allowing rapid analysis. Furthermore, on-line coupling of electrochemical cell with DESI-MS was demonstrated, in which perylene radical cations generated in the cell were successfully transferred to the gas-phase for MS detection by DESI. This study extended the scope of DESI-MS applications, which could have potentials in bioanalytical and forensic analysis.  相似文献   

12.
A novel microsystem device in poly(dimethylsiloxane) (PDMS) for MS detection is presented. The microchip integrates sample injection, capillary electrophoretic separation, and electrospray emitter in a single substrate, and all modules are fabricated in the PDMS bulk material. The injection and separation flow is driven electrokinetically and the total amount of external equipment needed consists of a three-channel high-voltage power supply. The instant switching between sample injection and separation is performed through a series of low-cost relays, limiting the separation field strength to a maximum of 270 V/cm. We show that this set-up is sufficient to accomplish electrospray MS analysis and, to a moderate extent, microchip separation of standard peptides. A new method of instant in-channel oxidation makes it possible to overcome the problem of irreversibly bonded PDMS channels that have recovered their hydrophobic properties over time. The fast method turns the channel surfaces hydrophilic and less prone to nonspecific analyte adsorption, yielding better separation efficiencies and higher apparent peptide mobilities.  相似文献   

13.
We describe a novel electrospray tip design for MS which is fabricated completely out of SU-8 photoepoxy. A three-layer SU-8 fabrication process provides fully enclosed channels and tips. The tip shape and alignment of all SU-8 layers is done lithographically and is therefore very accurate. Fabrication process enables easy integration of additional fluidic functions on the same chip. Separation channels can be made with exactly the same process. Fluidic inlets are made in SU-8 during the fabrication process and no drilling or other postprocessing is needed. Channels have been fabricated and tested in the size range of 10 microm x 10 microm-50 microm x 200 microm. Mass spectrometric performance of the tips has been demonstrated with both pressure-driven flow and EOF. SU-8 microtips have been shown to produce stable electrospray with EOF in a timescale of tens of minutes. With pressure driven flow stable spray is maintained for hours. Taylor cone was shown to be small in volume and well defined even with the largest channel cross section. The spray was also shown to be well directed with our tip design.  相似文献   

14.
Components for integrated poly(dimethylsiloxane) microfluidic systems   总被引:11,自引:0,他引:11  
This review describes the design and fabrication of microfluidic systems in poly(dimethylsiloxane) (PDMS). PDMS is a soft polymer with attractive physical and chemical properties: elasticity, optical transparency, flexible surface chemistry, low permeability to water, and low electrical conductivity. Soft lithography makes fabrication of microfluidic systems in PDMS particularly easy. Integration of components, and interfacing of devices with the user, is also convenient and simpler in PDMS than in systems made in hard materials. Fabrication of both single and multilayer microfluidic systems is straightforward in PDMS. Several components are described in detail: a passive chaotic mixer, pneumatically actuated switches and valves, a magnetic filter, functional membranes, and optical components.  相似文献   

15.
In this paper, we review the mass probes used for the derivation of a variety of biomolecules efficiently detected by the electrospray ionization-mass spectrometry and mass probe-assisted ionization method for total analysis and determination by consecutive detection with a single instrument. We describe mass probes for a variety of molecules including proteins, nucleobases, metallic cations, and other small molecules.  相似文献   

16.
Chang CH  Chen CJ  Chuang YC  Her GR 《Electrophoresis》2006,27(21):4303-4311
CEC-MS has been used for the analysis of eight-triazine herbicides. It showed significantly better S/N ratio than reversed EOF CE-MS and MEKC-MS, due to the lack of a surfactant in the separation buffer. By optimizing the pH, the organic content of the running buffer, and the separation potential, optimal separation was achieved within 18 min using a running buffer of pH 7.0, containing 70% v/v ACN, and an applied voltage of 17 kV. Gradient CEC showed superior separation when compared with isocratic elution. The combination of a tapered CEC column and a low-flow interface confers several advantages including better sensitivity, low dead volume, and independent control of the conditions used for CEC separation and ESI analysis.  相似文献   

17.
A survey of derivatization strategies and prospective derivatization reactions for conversion of simple alkenes and alkynes to 'electrospray-active' species is presented. General synthetic strategies are discussed and illustrative examples of prospective derivatives prepared from model compounds are presented along with their electrospray ionization (ES) mass spectra. The identified derivatives of these neutral, nonpolar analytes are either ionic or are ionizable in solution through Bronsted acid/base chemistry, by Lewis acid/base chemistry, or by chemical or electrochemical electron-transfer chemistry. Once ionized, the derivatives are expected to be amenable to detection by electrospray ionization-mass spectrometry. Derivatives are identified for positive and negative ion analysis of both alkenes and alkynes. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

18.
A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane)(PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 microL min(-1), respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 microL min(-1). To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.  相似文献   

19.
A method has been developed for the direct determination of coenzyme A (CoA) and organic acid-CoA thioesters in mixtures using directly combined liquid chromatography/electrospray ionization-mass spectrometry (LC/ESI-MS). Mixtures of CoA and organic acid-CoA thioesters were analyzed by LC/ESI-MS with detection of protonated molecular ions and characteristic fragment ions for each compound. The identities of the CoA-thioesters were established based on LC retention times and simultaneously recorded mass spectra. Monitoring of the CoA specific fragment ion at m/z 428 throughout the chromatogram provides a unique fingerprint for CoA content in the samples that corroborates the identification of organic acid-CoA thioesters in the mixtures. Furthermore, fragment ions arising from the ester linkage portion of the molecule allow unambiguous identification of the CoA esters in the samples. A second LC elution system was developed that allows the simultaneous separation and identification of 2-hydroxypropionyl-CoA (lactyl-CoA) and 3-hydroxypropionyl CoA (3HP-CoA), which have the same mass and identical MS fragmentation behavior. The utility of LC/ESI-MS employing this elution system is demonstrated by the determination of 3HP-CoA and lactyl-CoA (converted to CoA-thioesters from their corresponding free acids using CoA-transferase) in fermentation broths from Escherichia coli strains engineered for the production of 3-hydroxypropionic acid (3HP). External calibration employing a purified 3HP-CoA standard allowed indirect quantification of 3HP content in the broth with a precision of 1% (RSD). The feasibility of extending the method described above to perform LC/selected reaction monitoring-tandem mass spectrometry for direct determination of organic acid-CoA thioesters in cells was also demonstrated.  相似文献   

20.
Capillary electrophoresis-electrospray ionization-mass spectrometry has the potential to become a preferred tool for the analysis of biological mixtures and other complex samples. The development of improved interfaces in the past twenty years has been critical in demonstrating the feasibility of this technique. However, a compromise still exists between interfaces that give optimal performance and those that are practical for commercial applications. The first section of this review focuses on the technological advances in CE-ESI-MS as they relate to the key interface features for both sheath-flow and sheathless systems: delivery of the sheath liquid, shaping of the emitter tip, formation of electrical contact, and practicality in terms of ease of use and lifetime. In the second section, we review the fundamental processes that affect interface performance. Because of the complex natures of both capillary electrophoresis and electrospray ionization, flow rate, arrangement of the electrical circuit, electrochemistry, tip geometry and location of electrical contact must all be carefully managed in the design of a successful interface.  相似文献   