相似文献
 共查询到20条相似文献,搜索用时 756 毫秒
1.
亲水作用色谱-串联四极杆质谱测定液态奶中舒巴坦   总被引:1,自引:0,他引:1  
建立了亲水作用色谱-串联四极杆质谱测定液态奶中微量舒巴坦的分析方法。样品经0.2%乙酸水溶液提取,HLB固相萃取柱净化、富集,以甲酸铵-乙腈为流动相,经Acquity UPLC BEH HILIC色谱柱分离后采用电喷雾质谱多反应监测方式(MRM)扫描,外标法定量。结果表明,舒巴坦的质量浓度在1~100μg/L范围内线性关系良好,r2大于0.99,定量下限为1.0μg/kg。加标水平在1.0~50.0μg/kg范围时,回收率为82%~102%,相对标准偏差(RSD)为1.6%~4.7%。该方法前处理简便快捷、灵敏度高、回收率和重现性良好,适用于液态奶中舒巴坦的测定。  相似文献   

2.
The objective of this study was to develop a fast and robust method for the quantitation of the antifungal drug anidulafungin in human plasma samples by generic two-dimensional liquid chromatography (online-SPE/reversed phase LC) coupled to a tandem-quadrupole mass spectrometer (LC-online SPE-MS/MS). Online SPE was performed using an Oasis HLB cartridge column and for reversed-phase chromatography a Nucleodur Gravity C(18) column was used. A 100 μL aliquot of human plasma was extracted with 200 μL of 80:20 MeOH-0.2 M ZnSO(4) (v/v) as precipitation reagent containing ascomycin as internal standard (IS). The supernatant was directly injected for analysis. The total run time was 4.5 min. Anidulafungin and ascomycin were detected in the positive ionization mode. The method performance data for anidulafungin, such as limit of detection (0.013 μg/mL), lower limit of quantitation (0.04 μg/mL), linearity (R(2) = 0.9999) and concentration range (0.04-10 μg/mL) were ascertained. Intra- and inter-day precisions were ≤6.6% and intra- and inter-day accuracies were 98.5-101.0 and 100.0-102.5%, respectively. The assay was successfully applied for quantitation of anidulafungin in patient plasma samples.  相似文献   

3.
The detection and quantitation of apolipoproteins, important markers for coronary heart disease, in serum by liquid chromatography/tandem mass spectrometry (LC/MS/MS) using multiple reaction monitoring (MRM) is reported. A tryptic digest of depleted human serum was analysed by nanoflow LC/MS/MS at a flow rate of 300 nL/min and several apolipoproteins (Apo), including Apo A1, A2, A4, C1, C2, C3, D, F and M, were successfully identified. The analysis of the same depleted serum digest by ultra-performance (UP)LC/MS/MS operating at 700 microL/min resulted in comparable sensitivity and selectivity to the nanoflow method, but with a dramatic ( approximately 20-fold) reduction in run time. The potential of UPLC/MS/MS for the rapid quantitation of proteins in biological matrices by representative tryptic peptides was further investigated using Apo A1 and its corresponding stable isotopically labelled tryptic AQUA peptide (DYVSQFEGSALGK). A set of serum-based Apo A1 calibrators from a clinical analyser kit were digested without depletion following the addition of the AQUA peptide and analysed using UPLC/MS/MS. A linear calibration curve was generated from peak area ratios to the labelled peptide with a coefficient of correlation of 0.9989. Standard curves were also generated for other apolipoproteins together with Apo B100, Apo E, lecithin cholesterol acyltransferase and albumin, which were also detected in the standards. The concentration of Apo A1 in five fresh undepleted human serum samples and a quality control (QC) sample were determined using both the UPLC/MS/MS method and a clinical analyser. Results were comparable and the quantitative study, involving 80 injections which took hours rather than days to complete, demonstrates the high-throughput potential of UPLC/MS/MS to quantify multiple serum proteins without the need for antibodies, and thus provide an alternative to the use of clinical analysers for serum protein biomarkers.  相似文献   

4.
Sensitive and high-throughput bioanalytical assays are of vital importance to drug discovery and development. Ultra-performance liquid chromatography (UPLC), utilizing sub-2-microm particles, greatly increases the separation throughput and efficiency, resulting in LC peaks as narrow as or less than 1 s (full width at half maxima, FWHM). This, however, could pose practical challenges for bioanalytical applications using quadrupole mass spectrometry (MS) to acquire sufficient data points to ensure accurate and reliable quantitation. Here, we present a novel 'peak parking' strategy to reduce the flow rate during UPLC peak elution, therefore extending the useful MS acquisition window. The high-throughput advantage of UPLC is maintained since no significant increase of the overall UPLC run time is needed. This strategy was demonstrated in an assay development for lansoprazole, a gastric proton-pump inhibitor, in human plasma employing liquid-liquid extraction. The method was validated from 50.0 to 50,000 pg/mL.  相似文献   

5.
建立了超高效液相色谱-串联质谱(UPLC/MS/MS)检测土壤中多种环境基质下呋喃唑酮和氟苯尼考的方法.提取液采用磷酸盐缓冲溶液(pH=3)-乙腈(3:7,V/V),经过SPE固相萃取小柱SAX-HLB串联富集,使用Waters BEH C18色谱柱(2.1×100 mm)进行分离,UPLC/MS/MS在多反应监测模式下进行定性与定量分析.以3倍信噪比确定方法检出限,以10倍信噪比确定方法定量限.结果表明,本方法在5 min内即可分离两种物质,呋喃唑酮和氟苯尼考的检出限分别为1.19和0.41μg/kg;定量限分别为3.40和1.37μg/kg.50μg/L加标水平的呋喃唑酮和氟苯尼考的回收率分别为92%和79%;200μg/L加标水平下呋喃唑酮与氟苯尼考的回收率分别为96%和86%.  相似文献   

6.
Methamphetamine abuse continues as a major problem in the USA owing to its powerful psychological addictive properties. AZ66, 3‐[4‐(4‐cyclohexylpiperazine‐1‐yl)pentyl]‐6‐fluorobenzo[d]thiazole‐2(3H)‐one, an optimized sigma receptor ligand, is a promising therapeutic agent against methamphetamine. To study the in vivo pharmacokinetics of this novel sigma receptor ligand in rats, a sensitive ultra‐performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed in rat plasma and validated. The developed method requires a small volume of plasma (100 μL) and a simple liquid–liquid extraction. The chromatographic separations were achieved in 3.3 min using an Acquity UPLC BEH Shield RP18 column. The mass spectrophotometric detection was carried out using a Waters Micromass Quattro MicroTM triple‐quadrupole system. Multiple reaction monitoring was used for the quantitation with transitions m/z 406 → m/z 181 for AZ66 and m/z 448 → m/z 285 for aripiprazole. The method was validated over a concentration range of 1–3500 ng/mL and the lower limit of quantitation was determined to be 1 ng/mL. Validation of the assay demonstrated that the developed UPLC/MS/MS method was sensitive, accurate and selective for the determination of AZ66 in rat plasma. The present method has been successfully applied to an i.v. pharmacokinetic study in Sprague–Dawley rats. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
8.
Ultra-performance liquid chromatography (UPLC) was investigated as an alternative to high-performance liquid chromatography (HPLC) for analyzing pharmaceutical drug candidates. We previously developed a 96-well-based high-speed solubility assay system (HSSOL) using HPLC/UV and a LogD assay system (HSLogD) using HPLC/MS [Y. Dohta, T. Yamashita, S. Horiike, T. Nakamura, T. Fukami, Anal. Chem. 79 (2007) 8312]. We have introduced the UPLC/MS system into this previously developed HSSOL system to increase throughput. Results obtained by the UPLC/MS and HPLC/UV systems showed good agreement, validating the usefulness of the UPLC/MS system. A high-speed solubility assay system was developed employing the UPLC/MS system, thereby tripling the throughput.  相似文献   

9.
A rapid, sensitive, and reliable ultra‐performance liquid chromatography (UPLC) coupled with photodiode array detection method was developed for the amino acid analysis of Amur sturgeon (Acipenser schrenckii Brandt). The method uses minimal sample volume and automated online precolumn derivitization of amino acids with fluorescent 6‐aminoquinolyl‐carbamyl reagent. The chromatographic separation was achieved by UPLC, which used a column with 1.7 μm particle packing that enabled higher speed of analysis, peak capacity, greater resolution, and increased sensitivity. Amino acid derivatives obtained under optimal conditions were separated on a Waters UPLC BEH C18 column with Acetonitrile–acetate buffer as mobile phase. Matrix effects were investigated and good linearities with correlation coefficients better than 0.9949 were obtained over a wide range of 5–1000 μmol/L for all amino acids. The simple sample preparation and minimal sample volume make the method useful for the quantitation of 17 amino acids in Amur sturgeon samples. It is concluded that a rapid and robust platform based on UPLC was established, and a total of 17 amino acids of Amur sturgeon were tentatively detected. This method showed good accuracy and repeatability that can be used for the quantification of amino acids in real samples.  相似文献   

10.
The authors' laboratory at one time employed four liquid chromatography/mass spectrometric (LC/MS) methods for the detection of a large variety of drugs in equine urine. Drug classes covered by these methods included anti-diabetics, anti-ulcers, cyclooxygenase-2 (COX-2) inhibitors, sedatives, corticosteroids, anabolic steroids, sulfur diuretics, xanthines, etc. With the objective to reduce labour and instrumental workload, a new ultra performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method has been developed, which encompasses all target analytes detected by the original four LC/MS methods. The new method has better detection limits than the superseded methods. In addition, it covers new target analytes that could not be adequately detected by the four LC/MS methods. The new method involves solid-phase extraction (SPE) of two aliquots of equine urine using two Abs Elut Nexus cartridges. One aliquot of the urine sample is treated with β-glucuronidase before subjecting to SPE. A second aliquot of the same urine sample is processed directly using another SPE cartridge, so that drugs that are prone to decomposition during enzyme hydrolysis can be preserved. The combined eluate is analysed by UPLC/MS/MS using alternating positive and negative electrospray ionisation in the selected-reaction-monitoring mode. Exceptional chromatographic separation is achieved using an UPLC system equipped with a UPLC(?) BEH C18 column (10 cm L×2.1 mm ID with 1.7 μm particles). With this newly developed UPLC/MS/MS method, the simultaneous detection of 140 drugs at ppb to sub-ppb levels in equine urine can be achieved in less than 13 min inclusive of post-run equilibration. Matrix interference for the selected transitions at the expected retention times is minimised by the excellent UPLC chromatographic separation. The method has been validated for recovery and precision, and is being used regularly in the authors' laboratory as an important component of the array of screening methods for doping control analyses of equine urine samples.  相似文献   

11.
建立了凝胶渗透色谱(GPC)净化/超高效液相色谱-电喷雾串联四极杆质谱(UPLC-MS/MS)同时检测调味油中11种脂溶性偶氮类工业染料(苏丹红Ⅰ、苏丹红Ⅱ、苏丹红Ⅲ、苏丹红Ⅳ、苏丹红7B、苏丹红G、苏丹黄、苏丹橙G、苏丹蓝Ⅱ、甲苯胺红、对位红)和罗丹明B的分析方法。样品经乙酸乙酯-环己烷(1∶1)提取,采用凝胶渗透色谱(GPC)去除大分子油脂、天然色素等干扰物质;以乙腈-0.1%甲酸为流动相,目标化合物在梯度洗脱条件下经C18柱分离后采用多离子反应监测(MRM)正离子模式进行检测。结果表明:调味油中12种工业染料的线性范围为1~50μg/L,定量下限(LOQ)为0.2~2.5μg/kg,在5、20、40μg/L 3个加标水平下的回收率为54%~125%,相对标准偏差为2.5%~17.2%。随机抽取市售35份样品进行检测,其中两份样品检出罗丹明B。该方法操作简便、灵敏度高,实现了11种禁用偶氮染料和罗丹明B的同时提取和净化,适合于调味油中非法添加脂溶性偶氮工业染料和罗丹明B的筛查与确证。  相似文献   

12.
A rapid, sensitive and rugged solid‐phase extraction ultra performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method was developed for determination of paroxetine in human plasma. The procedure for sample preparation includes simple SPE extraction procedure coupled with Hypersil Gold C18 column (100 mm ? 2.1 mm, i.d., 1.9 μm) with isocratic elution at a flow‐rate of 0.350 mL/min and fluoxetine was used as the internal standard. The analysis was performed on a triple‐quadrupole tandem mass spectrometer by multiple reactions monitoring mode via electrospray ionization. Using 500 μL plasma, the methods were validated over the concentration range 0.050–16.710 ng/mL for paroxetine, with a lower limit of quantification of 0.050 ng/mL. The intra‐ and inter‐day precision and accuracy of the quality control samples were within 10.0%. The recovery was 69.2 and 74.4% for paroxetine and fluoxetine respectively. Total run time was only 1.9 min. The method was highly reproducible and gave peaks with excellent chromatography properties. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

13.
A new quantitation method for mass spectrometry imaging (MSI) with matrix-assisted laser desorption/ionization (MALDI) has been developed. In this method, drug concentrations were determined by tissue homogenization of five 10 μm tissue sections adjacent to those analyzed by MSI. Drug levels in tissue extracts were measured by liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS). The integrated MSI response was correlated to the LC/MS/MS drug concentrations to determine the amount of drug detected per MSI ion count. The study reported here evaluates olanzapine in liver tissue. Tissue samples containing a range of concentrations were created from liver harvested from rats administered a single dose of olanzapine at 0, 1, 4, 8, 16, 30, or 100 mg/kg. The liver samples were then analyzed by MALDI-MSI and LC/MS/MS. The MALDI-MSI and LC/MS/MS correlation was determined for tissue concentrations of ~300 to 60,000 ng/g and yielded a linear relationship over two orders of magnitude (R(2) = 0.9792). From this correlation, a conversion factor of 6.3 ± 0.23 fg/ion count was used to quantitate MSI responses at the pixel level (100 μm). The details of the method, its importance in pharmaceutical analysis, and the considerations necessary when implementing it are presented.  相似文献   

14.
A fast and robust high-throughput ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC–TOF MS) profiling method was developed and successfully applied to discriminate a total of 78 Bacillus cereus strains into no/low, medium and high producers of the emetic toxin cereulide. The data obtained by UPLC–TOF MS profiling were confirmed by absolute quantitation of cereulide in selected samples by means of high-performance liquid chromatography with tandem mass spectrometry (HPLC–MS/MS) and stable isotope dilution assay (SIDA). Interestingly, the B. cereus strains isolated from four vomit samples and five faeces samples from patients showing symptoms of intoxication were among the group of medium or high producers. Comparison of HEp-2 bioassay data with those determined by means of mass spectrometry showed differences, most likely because the HEp-2 bioassay is based on the toxic action of cereulide towards mitochondria of eukaryotic cells rather than on a direct measurement of the toxin. In conclusion, the UPLC–electrospray ionization (ESI)–TOF MS and the HPLC–ESI–MS/MS–SIDA analyses seem to be promising tools for the robust high-throughput analysis of cereulide in B. cereus cultures, foods and other biological samples.
Figure
Score plot (comp[1] vs. comp[2]) of UPLC‐TOF MS full scan analysis (50–1,300 Da) of 78 B. cereus strains with color‐coded signal intensity of the accurate mass of pseudo molecular ion of cereulide (m/z 1175.6608, [M+Na]+), from group 1 with the lowest up to group 5 with the highest signal intensity  相似文献   

15.
This paper describes the development and partial validation of a fast, sensitive and specific ultra-performance liquid chromatography/tandem mass spectrometric (UPLC/MS/MS) method for the determination of testosterone (T) and its four metabolites, 6beta-OH-T, 16alpha-OH-T, 16beta-OH-T and 2alpha-OH-T, in in vitro samples. The analytical method involves direct dilution of samples with acetonitrile containing an internal standard, followed by separation of testosterone and the four metabolites on an Acquity UPLCtrade mark C(18) column and detected by selected reaction monitoring (SRM) in positive ionization mode using turbo ionspray ionization. The parent compound and its metabolites investigated were well separated (Rs >1.5) with a run time of 4 min under a gradient condition. The method was partially validated. The linear concentration range was 0.01 to 5 microM for all the compounds of interest. Inter-assay mean bias and relative standard deviation (RSD) were in the range of -12% to 8% and 4.1% to 8.5%, respectively. Intra-assay mean bias and RSD were in the range of -8.0% to 5.2% and 3.4% to 9.6%, respectively. The lower limit of quantitation for this assay was 0.01 microM. The differences in LC/MS performance were investigated by conducting a comparison of UPLC with another method previously optimized for HPLC-based separation and quantification of testosterone and its metabolites.  相似文献   

16.
An assay method with mass spectrometric detection was developed for the quantitative analysis of a pharmaceutical compound and its major metabolite in human plasma using chip-based infusion. Liquid-liquid extraction sample preparation was found to be essential to minimize matrix suppression and to achieve a limit of quantitation (LOQ) of 2.5 ng/mL using a 100 microL plasma aliquot. The potential for simultaneous quantitation in selected reaction monitoring (SRM), tandem mass spectrometry (MS/MS) (enhanced product ion), and MS(3) was investigated and found to be very beneficial in improving assay selectivity. A novel concept for monitoring quantitative assay performance using a SRM/MS(3) ratio is proposed.  相似文献   

17.
A high-throughput liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) assay using automated sample preparation has been developed for the determination of valproic acid (VPA) in mouse plasma. A liquid-handling system was programmed to prepare calibration standard solutions in plasma, as well as quality controls and clinical samples. Plasma protein precipitation was performed on a 96-well plate, and the collected supernatant was directly injected into a reversed-phase LC/ESI-MS/MS system in the negative ionization mode. The calibration curve for VPA was linear over a dynamic range of 0.15-100 microg/mL. The limit of detection was 75 ng/mL and the lower limit of quantitation was 150 ng/mL. Intra- and inter-day validation assays of the semi-automated plasma analysis showed satisfactory accuracy and precision.  相似文献   

18.
Yang W  Wang J  Li X  Du Z 《Journal of chromatography. A》2011,1218(11):1423-1428
Crocin yellow was determined in soft drinks, sausages and sauces by ultra performance liquid chromatography coupled with ultraviolet detector and analyzed within 5 min using a short analytical column ACQUITY UPLC HSS T3 2.1 x 100 mm 1.8 μm) with gradient elution. An innovative pretreatment method based on homemade macroporous resin solid-phase extraction (SPE) column was established. The SPE column packed with macroporous resins could simplify the sample preparation of multi-matrices and be reused by regeneration steps. The recoveries of crocin yellow added to soft drinks, sausages and sauces at three levels ranged from 81.3% to 106.2%, and relative standard deviations (RSDs) were within 8.8%. The limits of quantitation of soft drinks, sausages and sauces were 0.5 mg/kg, 5 mg/kg and 5 mg/kg, respectively.  相似文献   

19.
A speedy and selective ultra‐HPLC‐MS/MS method for simultaneous determination of deoxynivalenol (DON), 3‐acetyldeoxynivalenol (3‐ADON), 15‐ADON, nivalenol and fusarenon X in traditional Chinese medicines (TCMs) was developed. The method was based on one‐step sample cleanup using reliable homemade cleanup cartridges. A linear gradient mobile‐phase system, consisting of water containing 0.2% aqueous ammonia and acetonitrile/methanol (90:10, v/v) at a flow rate of 0.4 mL/min, and an Acquity UPLC HSS T3 column (100 mm×2.1 mm, 1.8 μm) were employed to obtain the best resolution of the target analytes. [13C15]–DON was used as the internal standard to accomplish as accurate as possible quantitation. The established method was further validated by determining the linearity (R2≥0.9990), sensitivity (LOQ, 0.29–0.99 μg/kg), recovery (88.5–119.5%) and precision (RSD≤15.8%). It was shown to be a suitable method for simultaneous determination of DON, 3‐ADON, 15‐ADON, nivalenol and fusarenon X in various TCM matrices. The utility and practical impact of the method was demonstrated using different TCM samples.  相似文献   

20.
The utility of ultra-performance liquid chromatography/orthogonal-acceleration time-of flight mass spectrometry (UPLC/TOFMS) for the rapid qualitative and quantitative analysis of 100 pesticides targeted in strawberry was assessed by comparing results with those obtained using a validated in-house UPLC tandem mass spectrometry (MS/MS) multi-residue method. Crude extracts from retail strawberry samples received as part of the 2007 annual UK pesticide residues in food surveillance programme were screened for the presence of pesticide residues using UPLC/TOFMS. Accurate mass measurement of positive and negative ions allowed their extraction following 'full mass range data acquisition' with negligible interference from background or co-eluting species observed during UPLC gradient separation (in a cycle time of just 6.5 min per run). Extracted ion data was used to construct calibration curves and to detect and identify any incurred residues (i.e. pesticides incorporated in or on the test material following application during cultivation, harvest and storage). Calibration using matrix-matched standards was performed over a narrow concentration range of 0.005-0.04 mg kg(-1) with determination coefficients (r2) > or =0.99 for all analytes with the exception of malathion/fenarimol/fludioxanil (r2 = 0.98), quassia/pymetrazine (r2 = 0.97) and fenthion sulfone (r2 = 0.95). Residues found in selected samples ranged from 0.025-0.28 mg kg(-1) and were in excellent agreement with results obtained using UPLC/MS/MS. Mass measurement accuracies of < or =5 ppm were achieved consistently throughout the separation, mass range and concentration range of interest thus providing the opportunity to obtain discrete elemental compositions of target ions.  相似文献   