首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
Comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC-TOFMS) was used for the characterization of aromatic compounds present in extra heavy gas oil (EHGO) from Brazil. Individual identification of EHGO compounds was successfully achieved in addition to group-type separation on the chromatographic plane. Many aromatic hydrocarbons, especially polycyclic aromatic hydrocarbons and sulfur compounds, were detected and identified, such as chrysenes, phenanthrenes, perylenes, benzonaphthothiophenes and alkylbenzonaphthothiophenes. In addition, triaromatic steroids, methyl-triaromatic steroids, tetrahydrochrysenes and tetraromatic pentacyclic compounds were present in the EHGO aromatic fractions. Considering the roof-tile effect observed for many of these compound classes and the high number of individual compounds identified, GC×GC-TOFMS is an excellent technique to characterize the molecular composition of the aromatic fraction from EHGO samples. Moreover, data processing allowed the quantification of aromatic compounds, in class and individually, using external standards. EHGO data were obtained in μgg(-1), e.g., benzo[a]pyrene were in the range 351 to 1164μgg(-1). Thus, GC×GC-TOFMS was successfully applied in EHGO quantitative analysis.  相似文献   

2.
The applicability of comprehensive two-dimensional gas chromatography (GC×GC) for flavonoids analysis was investigated by separation and identification of flavonoids in standards, and a complex matrix natural sample. The modulation temperature was optimized to achieve the best separation and signal enhancement. The separation pattern of trimethylsilyl (TMS) derivatives of flavonoids was compared on two complementary column sets. Whilst the BPX5/BPX50 (NP/P) column set offers better overall separation, BPX50/BPX5 (P/NP) provides better peak shape and sensitivity. Comparison of the identification power of GC×GC-TOFMS against both the NIST05 MS library and a laboratory (created in-house) TOFMS library was carried out on a flavonoid mixture. The basic retention index information on high-performance capillary columns with a non-polar stationary phase was established and database of mass spectra of trimethylsilyl derivatives of flavonoids was compiled. TOFMS coupled to GC×GC enabled satisfactory identification of flavonoids in complex matrix samples at their LOD over a range of 0.5-10 μg/mL. Detection of all compounds was based on full-scan mass spectra and for each compound a characteristic ion was chosen for further quantification. This study shows that GC×GC-TOFMS yields high specificity for flavonoids derived from real natural samples, dark chocolate, propolis, and chrysanthemum.  相似文献   

3.
Combining qualitative data from the chromatographic structure of 2-D gas chromatography with flame ionization detection (GC×GC-FID) and that from gas chromatography-mass spectrometry (GC/MS) should result in a more accurate assignment of the peak identities than the simple analysis by GC/MS, where coelution of analytes is unavoidable in highly complex samples (rendering spectra unsuitable for qualitative purposes) or for compounds in very low concentrations. Using data from GC×GC-FID combined with GC/MS can reveal coelutions that were not detected by mass spectra deconvolution software. In addition, some compounds can be identified according to the structure of the GC×GC-FID chromatogram. In this article, the volatile fractions of fresh and dehydrated pineapple pulp were evaluated. The extraction of the volatiles was performed by dynamic headspace extraction coupled to solid-phase microextraction (DHS-SPME), a technique appropriate for slurries or solid matrices. Extracted analytes were then analyzed by GC×GC-FID and GC/MS. The results obtained using both techniques were combined to improve compound identifications.  相似文献   

4.
Comprehensive two-dimensional gas chromatography (GC x GC) analysis has the capability to resolve many more components of complex mixtures than traditional single column GC analysis. There is an increasing need to provide reliable identification of these separated components; time-of-flight mass spectrometry (TOFMS) is the most appropriate technology to achieve this task. Rather than require MS for all GC x GC separations, it is desirable to assign peak identities to specific peak positions in the GC x GC separation space, and this necessitates matching peak retentions in the two experiments - GC x GC-FID and GC x GC-TOFMS. The atmospheric vs. vacuum outlet conditions confound this task. It is shown here that by employing a supplementary gas supply, provided to a T-union between the column outlet and the MS interface, it is possible to generate 2D chromatograms for GC x GC-FID and GC x GC-TOFMS that are essentially exactly matched. There is no degradation in separation performance or efficiency in the second column in the system interfaced to the T-union. Since the GC x GC-FID experiment uses hydrogen for maximum efficiency, and GC x GC-TOFMS uses helium carrier, translation of (conditions/retentions) must account for the different viscosities of the carrier gases. Translation of conditions is based on well-known principles established in single column analysis. Tabulated data illustrate that retention reproducibility was of the order of better than 4 s for the average first dimension retention difference, and about 40 ms for the average second dimension retention difference when comparing GC x GC-FID and GC x GC-TOFMS results. This should provide considerable support for identification in routine GC x GC-FID analysis of specific sample types, once the peaks in 2D separation space have been assigned identities through GC x GC-TOFMS analysis.  相似文献   

5.
Comprehensive two-dimensional gas chromatography with flame ionization detection (GC x GC-FID) was used to measure alkene-based drilling fluids in crude oils. Compared to one-dimensional gas chromatography, GC x GC-FID is more robust for detecting alkenes due to the increased resolution afforded by second dimension separations. Using GC x GC-FID to analyze four oil samples from one reservoir contaminated with the same drilling fluid, C(15), C(16), C(17), C(18) and C(20) alkenes were identified. The drilling fluid that contaminated these samples also differed from another commercially obtained fluid, which only contained C(16) and C(18) alkenes. These results should motivate the petroleum industry to consider GC x GC-FID for measuring drilling fluids.  相似文献   

6.
Coal is a non renewable fossil fuel, used mainly as a source of electrical energy and in the production of coke. It is subjected to thermal treatment, pyrolysis, which produces coke as a main product, in addition to a condensed liquid by-product, called tar. Tar is a complex mixture of organic compounds which contains different chemical classes, presenting aromatic and sulphur heterocyclic compounds. In general, identification of these compounds requires steps of isolation and fractionation, mainly due to co-elution of these compounds with polyaromatic hydrocarbons (PAH). The objective of this work is to characterize the sulphur compounds present in the coal tar obtained via pyrolysis, using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detector (GC×GC/TOFMS). Coal samples from the State of Paraná, Brazil were subjected to laboratorial scale pyrolysis. Several experimental conditions were tested, such as sample weight (5, 10 and 15g), heating ramp (10, 25 and 100°C/min) and final temperature (500, 700 and 900°C). Samples were analyzed by one dimensional gas chromatography (1D-GC) coupled to a quadrupole mass spectrometry detector (GC/qMS) and two-dimensional gas chromatography with time-of-flight mass spectrometry detector (GC×GC/TOFMS). The higher amount of sulphur compounds was obtained at a final temperature of 700°C and a heating ramp of 100°C/min. The main classes observed in the color plot were thiophenes, benzothiophenes and alkylated dibenzothiophenes. GC×GC/TOFMS allowed the identification of the greater number of compounds and the separation of several sulphur compounds from one another. Moreover, separation of sulphur compounds from polyaromatic hydrocarbons and phenols was achieved, which was not possible by 1D-GC. Comparing GC×GC/TOFMS and 1D-GC (SIM mode) also showed that 1D-GC, one of the most employed quantification tools for sulphur compounds, can be misleading for detection, identification and quantification, as the number of isomers of sulphur compounds found was greater than theoretically possible.  相似文献   

7.
The accurate establishment of oil similarity is a longstanding problem in petroleum geochemistry and a necessary component for resolving the architecture of an oil reservoir. Past limitations have included the excessive reliance on a relatively small number of biomarkers to characterize such complex fluids as crude oils. Here we use multiway principal components analysis (MPCA) on large numbers of specific chemical components resolved with comprehensive two-dimensional gas chromatography-flame ionization detection (GC×GC-FID) to determine the molecular relatedness of eight different maltene fractions of crude oils. MPCA works such that every compound eluting within the same first and second dimension retention time is quantitatively compared with what elutes at that same retention times within the other maltene fractions. Each maltene fraction and corresponding MPCA analysis contains upwards of 3500 quantified components. Reservoir analysis included crude oil sample pairs from around the world that were collected sequentially at depth within a single well, collected from multiple depths in the same well, and from different depths and different wells but thought to be intersected by the same permeable strata. Furthermore, three different regions of each GC×GC-FID chromatograms were analysed to evaluate the effectiveness of MPCA to resolve compositional changes related to the source of the oil generating sediments and its exposure to biological and/or physical weathering processes. Compositional and instrumental artefacts introduced during sampling and processing were also quantitatively evaluated. We demonstrate that MPCA can resolve multi-molecular differences between oil samples as well as provide insight into the overall molecular relatedness between various crude oils.  相似文献   

8.
Perinatal asphyxia is a leading cause of brain injury in infants, occurring in 2-4 per 1000 live births. The clinical response to asphyxia is variable and difficult to predict with current diagnostic tests. Reliable biomarkers are needed to help predict the timing and severity of asphyxia, as well as response to treatment. Two-dimensional gas chromatography-time-of-flight-mass spectrometry (GC×GC-TOFMS) was used herein, in conjunction with chemometric data analysis approaches for metabolomic analysis in order to identify significant metabolites affected by birth asphyxia. Blood was drawn before and after 15 or 18 min of cord occlusion in a Macaca nemestrina model of perinatal asphyxia. Postnatal samples were drawn at 5 min of age (n=20 subjects). Metabolomic profiles of asphyxiated animals were compared to four controls delivered at comparable gestational age. Fifty metabolites with the greatest change pre- to post-asphyxia were identified and quantified. The metabolic profile of post-asphyxia samples showed marked variability compared to the pre-asphyxia samples. Fifteen of the 50 metabolites showed significant elevation in response to asphyxia, ten of which remained significant upon comparison to the control animals. This metabolomic analysis confirmed lactate and creatinine as markers of asphyxia and discovered new metabolites including succinic acid and malate (intermediates in the Krebs cycle) and arachidonic acid (a brain fatty acid and inflammatory marker) as potential biomarkers. GC×GC-TOFMS coupled with chemometric data analysis are useful tools to identify acute biomarkers of brain injury. Further study is needed to correlate these metabolites with severity of disease, and response to treatment.  相似文献   

9.
The present paper describes an investigation directed toward the development of a rapid heart-cutting LC-GC method for the analysis of mineral oil saturated hydrocarbons contained in vegetable oils. The automated LC-GC experiments were carried out by using a system equipped with a syringe-type interface, capable of both heart-cutting and comprehensive (LC × GC) two-dimensional analysis. The first dimension separation was achieved on a 100 mm × 3 mm ID × 5 μm d(p) silica column, operated under isocratic conditions (hexane). A single 30-s cut, corresponding to a 175 μL volume, was transferred to a programmed temperature vaporizer. After the large volume injection, the target analytes were separated in a rapid manner (~9 min) using a 15 m × 0.1mm ID × 0.1 μm micro-bore GC capillary. The overall LC-GC run time enables the analysis of ca. 4 samples/hour. Quantification was performed by using external calibration, in the 1-200 mg/kg range. The method was validated in terms of linearity, precision, limits of detection and quantification, and accuracy. A series of commercial samples were subjected to analysis. Various degrees of contamination were found in all samples, in the 7.6-180.6 mg/kg range.  相似文献   

10.
The use of multivariate curve resolution (MCR) to build multivariate quantitative models using data obtained from comprehensive two-dimensional gas chromatography with flame ionization detection (GC × GC-FID) is presented and evaluated. The MCR algorithm presents some important features, such as second order advantage and the recovery of the instrumental response for each pure component after optimization by an alternating least squares (ALS) procedure. A model to quantify the essential oil of rosemary was built using a calibration set containing only known concentrations of the essential oil and cereal alcohol as solvent. A calibration curve correlating the concentration of the essential oil of rosemary and the instrumental response obtained from the MCR-ALS algorithm was obtained, and this calibration model was applied to predict the concentration of the oil in complex samples (mixtures of the essential oil, pineapple essence and commercial perfume). The values of the root mean square error of prediction (RMSEP) and of the root mean square error of the percentage deviation (RMSPD) obtained were 0.4% (v/v) and 7.2%, respectively. Additionally, a second model was built and used to evaluate the accuracy of the method. A model to quantify the essential oil of lemon grass was built and its concentration was predicted in the validation set and real perfume samples. The RMSEP and RMSPD obtained were 0.5% (v/v) and 6.9%, respectively, and the concentration of the essential oil of lemon grass in perfume agreed to the value informed by the manufacturer. The result indicates that the MCR algorithm is adequate to resolve the target chromatogram from the complex sample and to build multivariate models of GC × GC-FID data.  相似文献   

11.
The present research is focused on the use of comprehensive 2-D GC (GCxGC) for the thorough elucidation of fatty acid (FA) profiles contained in vegetable oils; the samples analysed consisted of extra-virgin olive oil and refined hazelnut oil. The enhanced sensitivity and the formation of group-type patterns provided by GCxGC enabled the identification and quantification of both well-known and rather unexpected FAs contained in the lipid matrices. Peak assignment was, in most cases, supported by using pure standard compounds. Of particular interest was the identification of a series of odd-numbered FAs in both samples. The results attained to demonstrate the usefulness of GCxGC also for the analysis of supposedly low-complex samples.  相似文献   

12.
The potential of comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry (GC×GC-TOFMS) in the quantitative analysis of amino acid enantiomers (AAEs) as their methyl chloroformate (MCF) derivatives in physiological fluids was investigated. Of the two column sets tested, the combination of an Rt-γDEXsa chiral column with a polar ZB-AAA column provided superior selectivity. Twenty AAEs were baseline resolved including L-Leu and D-Ile, which had failed separation by one-dimensional chiral GC-quadrupole-MS (GC-qMS). Lower limits of quantification (LLOQ) were in the range of 0.03-2 μM. Reproducibility of the analysis of a serum specimen in octaplicate ranged from 1.3 to 16.6%. The GC×GC-TOFMS method was validated by analyzing AAEs in 48 urine and 43 serum specimens, respectively, and by comparing the results with data obtained by a previously validated GC-qMS method. Mean recoveries ranged from 78.4% for D-Leu to 116.4% for D-Pro in urine and 72.2% for L-Thr to 129.4% for L-Ile in serum. The method was applied to the comparison of AAE serum levels in patients suffering from liver cirrhosis to a control group. Significantly increased D-AA concentrations were found for the patient group, whereas L-AA levels were slightly decreased.  相似文献   

13.
Volatile constituents in wine and brewed coffee were analyzed using a combined system incorporating both GC-olfactometry (GC-O) and comprehensive two-dimensional GC-flame ionization detection (GC×GC-FID). A column set consisting of a 15m first dimension ((1)D; DB-FFAP (free fatty acid phase)), and a 1.0m (2)D column (DB-5 phase) was applied to achieve the GC×GC separation of the volatile extracts isolated by using solid phase extraction (SPE). While 1D GC resulted in many overlapping peaks, GC×GC allowed resolution of co-eluting compounds which coincided with the odour region located using GC-O. Character-impact odourants were tentatively identified through data correlation of GC×GC contour plots across results obtained using either time-of-flight mass spectrometry (TOFMS), or with flame photometric detection (FPD) for sulfur speciation. The odourants 2-methyl-2-butenal, 2-(methoxymethyl)-furan, dimethyl trisulfide, 2-ethyl-5-methyl-pyrazine, 2-octenal, 2-furancarboxaldehyde, 3-mercapto-3-methyl-1-butanol, 2-methoxy-3-(2-methylpropyl)-pyrazine, 2-furanmethanol and isovaleric acid were suspected to be particularly responsible for coffee aroma using this approach. The presented methodology was applied to identify the potent odourants in two different Australian wine varietals. 1-Octen-3-ol, butanoic acid and 2-methylbutanoic acid were detected in both Merlot and a Sauvignon Blanc+Semillon (SV) blend with high aroma potency. Several co-eluting peaks of ethyl 4-oxo-pentanoate, 3,7-dimethyl-1,5,7-octatrien-3-ol, (Z)-2-octen-1-ol, 5-hydroxy-2-methyl-1,3-dioxane were likely contributors to the Merlot wine aroma; while (Z)-3-hexen-1-ol, β-phenylethyl acetate, hexanoic acid and co-eluting peaks of 3-ethoxy-1-propanol and hexyl formate may contribute to SV wine aroma character. The volatile sulfur compound 2-mercapto-ethyl acetate was believed to contribute a fruity, brothy, meaty, sulfur odour to Australian Merlot and SV wines.  相似文献   

14.
Zhang Y  Tobias HJ  Brenna JT 《The Analyst》2012,137(13):3102-3110
Comprehensive two dimensional gas chromatography (GC × GC) provides greater separation space than conventional GC. Because of fast peak elution, a time of flight mass spectrometer (TOFMS) is the usual structure-specific detector of choice. The quantitative capabilities of a novel GC × GC fast quadrupole MS were investigated with electron ionization (EI), and CH(4) or NH(3) positive chemical ionization (PCI) for analysis of endogenous urinary steroids targeted in anti-doping tests. Average precisions for steroid quantitative analysis from replicate urine extractions were 6% (RSD) for EI and 8% for PCI-NH(3). The average limits of detection (LODs) calculated by quantification ions for 12 target steroids spiked into steroid-free urine matrix (SFUM) were 2.6 ng mL(-1) for EI, 1.3 ng mL(-1) for PCI-CH(4), and 0.3 ng mL(-1) for PCI-NH(3), all in mass scanning mode. The measured limits of quantification (LOQs) with full mass scan GC × GC-qMS were comparable with the LOQ values measured by one-dimensional GC-MS in selected ion monitoring (SIM) mode. PCI-NH(3) yields fewer fragments and greater (pseudo)molecular ion abundances than EI or PCI-CH(4). These data show that a benchtop GC × GC-qMS system has the sensitivity, specificity, and resolution to analyze urinary steroids at normal urine concentrations, and that PCI-NH(3), not currently available on most GC × GC-TOFMS instruments, is of particular value for generation of structure-specific ions.  相似文献   

15.
Pyrolysis oil and upgraded products are promising energy carriers. Characterisation of the oils is hampered due to the presence of a large number of components (>400) belonging to a broad variety of chemical compound classes (i.e., acids, aldehydes, ketones). In this study, a comparison of the capabilities of 2D-GC-FID and GC-MS to determine the molecular composition of these oils is made. As such, it represents a chromatographic study for a real application in green catalytic technology. Split-injection of the oil samples, diluted in tetrahydrofuran (THF), was applied without any sample pre-treatment. GC-MS application resulted in coelution, while 2D-GC showed significantly higher chromatographic resolution. Model compound mixtures were used for compound identification in the 2D-GC analysis while GC-MS was used to confirm the molecular structures. The combination of both 2D-GC-FID and GC-MS proved to be a useful method, without the requirement of a 2D-GC/TOF instrument. The technique was applied successfully to identify and quantify the main components in pyrolysis oil and upgraded pyrolysis oil made by hydrodeoxygenation (HDO) technology. Compared to GC-MS, 2D-GC-FID provides a fast overview of the various chemical compound classes present in the oils.  相似文献   

16.
Since the isolation of artemisinin 32 years ago, it has been analyzed by different chromatographic techniques. This work compared the analysis of artemisinin from crude plant samples by GC with flame ionization detection (GC-FID) and HPLC with evaporative light scattering detector (HPLC-ELSD). Data is also presented indicating that GC is suitable for the quantification of two of artemisinin precursors (arteannuin B and artemisinic acid) if a mass spectrometer is available. GC-FID and HPLC-ELSD were chosen because of their low cost compared to other detection methods, their ease of operation compared to HPLC with electrochemical detection, and because neither require artemisinin derivatization. Both GC-FID and HPLC-ELSD provided sensitive (ng level) and reproducible results for the analysis of artemisinin from field plants, with a correlation coefficient of r(2)=0.86 between the two methods. Both methods could be easily adapted to the analysis of pharmaceutical-grade artemisinin.  相似文献   

17.
The present investigation is focused on a simple flow modulator (FM), for comprehensive two-dimensional gas chromatography (GC×GC). The interface is stable at high temperatures, and consists of a metallic disc (located inside the GC oven) with seven ports, which are connected to an auxiliary pressure source via two branches, to the first and second dimension, to a waste branch (linked to a needle valve) and to an exchangeable modulation loop (2 ports). The ports are connected via micro-channels, etched on one of the inner surfaces of the disc. Modulation is achieved using a two-way electrovalve, connected on one side to the additional pressure source, and to the two metal branches, on the other. An FM enantio-GC×polar-GC method (using a flame ionization detector) was optimized (a 40-μL loop was employed), for the analysis of essential oils. As an example, an application on spearmint oil is shown; the method herein proposed was subjected to validation. Finally, an FM GC×GC diesel experiment was carried out, using an apolar-polar column combination, to demonstrate the effectiveness of the modulator in the analysis of a totally different sample-type.  相似文献   

18.
Valve based/flow modulated comprehensive two-dimensional gas chromatography-flame ionization detection (GC x GC-FID) was used for quantification of C6 through C12 aromatic hydrocarbons by carbon number in gasolines. A 0.53 mm i.d. non-polar first dimension column was coupled to a 0.53 mm i.d. polar second dimension column through a double loop eight port valve modulator. Depending on the sample type, normalized percent and internal standard (I.S.) quantification was performed. For normalized percent quantification, a one-point calibration performed with one aromatic compound per carbon number/class provided an average % accuracy of 2.1% and a short-term n--1 relative standard deviation of 1.0%. For total aromatic compounds good agreement with the more complex conventional multidimensional GC technique was obtained. However, GC x GC has certain advantages over most other methods, mainly increased selectivity for total and carbon number aromatic content. The identification of the aromatic hydrocarbons was confirmed by GC x GC-MS.  相似文献   

19.
Giacometti J 《The Analyst》2001,126(4):472-475
In general, analyses for aliphatic alcohols, sterols and tocopherols in vegetable oils are performed separately. A simple and reliable procedure is presented for the quantification of the alkanols, squalene, alpha-tocopherol and sterols in olive oils by a direct method involving gas chromatographic (GC) analysis of the unsaponifiable fraction after silylation. The method eliminates the need for a preliminary thin-layer chromatographic (TLC) fractionation prior to GC. External standard calibration with reference substances was used for the quantification of squalene, alpha-tocopherol and sterols and internal standard calibration for the quantification of aliphatic alcohols. The analyte recovery and the repeatability of the quantitative results were evaluated and were acceptable for routine use.  相似文献   

20.
全二维气相色谱(GC×GC)是20世纪90年代发展起来的具有高分辨率、高灵敏度、高峰容量等优势的分离技术,在我国将其用于大气挥发性有机物(VOCs)研究方面才刚刚起步.本文将GC-GC与氢火焰离子化检测器(FID)联用,构建了用于测量大气有机物的热脱附-全二维气相色谱-氢火焰离子化分析系统(TD-GC×GC-FID).采用HP-5MS和HP-INNOWAX色谱柱,建立了C5-C15大气有机物分析方法,实现了一次分析过程同时分离非甲烷烃(NMHCs)、含氧挥发性有机物(OVOCs)和卤代烃等多种组分.利用标准物质和四级杆质谱(qMS)进行定性,外标法结合FID质量校正因子定量.目标物在GC-GC谱图中第一和第二维保留时间变化分别小于0.6s和0.02s,峰体积平均相对标准偏差为14.3%,其中烷烃和芳香烃为4.5%.标准曲线r2均值大于0.99,平均检出限为6.04ng,平均回收率为111%.利用该方法检测到2010年1月北京市区大气中400多种有机物(信噪比大于50),鉴定了其中的103种物质,包括烷烃、烯烃、芳香烃、卤代烃、醛、酮、酯、醇和醚等.所测定有机物平均总浓度为51.3×10-9V/V,其中OVOCs约占51%,芳香烃约占30%,烷烃约占15%,卤代烃和烯烃分别占3%和1%.平均浓度最高的前3个组分是乙醇(9.84×10-9V/V)、丙酮(6.72×10-9V/V)和甲苯(3.48×10-9V/V).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号