首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel on-line HPLC-DTNB method was developed for the selective determination of biologically important thiols (biothiols) such as l-cysteine (Cys), glutathione (GSH), homocysteine (HCys), N-acetylcysteine (NAC), and 1,4-dithioerythritol (DTE) in pharmaceuticals and tissue homogenates. The biothiols were separated on C18 column using gradient elution, reacted with the postcolumn reagent, DTNB in 0.5% M-β-CD (w/v) solution at pH 8, to form yellow-colored 5-thio-2-nitrobenzoic acid (TNB), and monitored with a PDA detector (λ = 410 nm). With the optimized conditions for chromatography and the post-column derivatization, 40 nM of NAC, 40 nM of Cys, and 50 nM of GSH can be determined. The relative standard deviations of the recommended method were in the range of 3.2–5.4% for 50 μM biothiols. The negative peaks of biothiol constituents were monitored by measuring the increase in absorbance due to TNB chromophore. The detection limits of biothiols at 410 nm (in the range of 0.04–0.58 μM) after post-column derivatization with DTNB + M-β-CD were much lower than those at 205 nm UV-detection without derivatization, and were distinctly lower than those with post-column DTNB alone. The method is rapid, inexpensive, versatile, nonlaborious, uses stable reagents, and enables the on-line qualitative and quantitative estimation of biothiol constituents of biological fluids and pharmaceuticals.  相似文献   

2.
A novel on-line HPLC-cupric reducing antioxidant capacity (CUPRAC) method was developed for the selective determination of polyphenols (flavonoids, simple phenolic and hydroxycinnamic acids) in complex plant matrices. The method combines chromatographic separation, constituent analysis, and post-column identification of antioxidants in plant extracts. The separation of polyphenols was performed on a C18 column using gradient elution with two different mobile phase solutions, i.e., MeOH and 0.2% o-phosphoric acid. The HPLC-separated antioxidant polyphenols in the extracts react with copper(II)-neocuproine (Cu(II)-Nc) reagent in a post-column reaction coil to form a derivative. The reagent is reduced by antioxidants to the copper(I)-neocuproine (Cu(I)-Nc) chelate having maximum absorption at 450 nm. The negative peaks of antioxidant constituents were monitored by measuring the increase in absorbance due to Cu(I)-Nc. The detection limits of polyphenols at 450 nm (in the range of 0.17-3.46 μM) after post-column derivatization were comparable to those at 280 nm UV detection without derivatization. The developed method was successfully applied to the identification of antioxidant compounds in crude extracts of Camellia sinensis, Origanum marjorana and Mentha. The method is rapid, inexpensive, versatile, non-laborious, uses stable reagents, and enables the on-line qualitative and quantitative estimation of antioxidant constituents of complex plant samples.  相似文献   

3.
The aim of this work was to modify and validate the post-column high-performance liquid chromatography (HPLC)-ABTS and DPPH methods for evaluating the antioxidant activity of the methanolic extracts of Solidago canadensis (Canadian goldenrod) leaves and flowers. Separation of the analytes was performed via the HPLC-PDA method on a YMC analytical column using a gradient elution program. Three compounds with antioxidant properties – chlorogenic acid, rutin and isoquercitrin – and two unidentified antioxidants were established. The research showed that the coil temperature regimes and loop length combinations influence the optimised post-column assay method for detecting the antioxidant activity of goldenrod radical scavengers. Investigations established that the temperature in the reaction coil was a substantial factor contributing to the signal strength of the analytes after reacting with the DPPH and ABTS radicals.  相似文献   

4.
Summary The use of solid-phase reactors for post-column derivatization in narrow-bore HPLC (1.0mm i.d. analytical columns) is evaluated. Two systems are described, viz. for the determination of N-methylcarbamate pesticides and for that of urea and ammonia. The solid-phase reactor is packed with a strong anion exchange resin and urease immobilized on silica, respectively, to effect the catalytic hydrolysis of the solutes eluting from the analytical column. In both systems, the hydrolysis product is reacted with o-phthalaldehyde followed by fluorescence monitoring. Analytical data are presented and band broadening from various parts of the reaction detector system is discussed. An on-line trace enrichment procedure via a micro precolumn is descried for the trace level determination of N-methylcaramates in surface water samples.  相似文献   

5.
For the simple and fast preparation of highly reliable standard materials, a post-column reaction GC/FID system was developed and evaluated on the mixture of oxygen-containing organic compounds. The oxygen-containing organic compounds mixing solution were determined with the post-column reaction GC/FID system using n-dodecane as an internal calibration standard. Required value of relative expanded uncertainty as an original source of SI-traceable standard materials was within 1% and it aimed at this value as accuracy of the quantitative analysis. The results showed good agreement between the prepared concentrations and analytical values using post-column reaction GC/FID system. These results indicated that the post-column reaction GC/FID system would be used for getting SI-traceable values.  相似文献   

6.
Reactive oxygen species (ROS) can damage proteins, cause lipid peroxidation, and react with DNA, ultimately resulting in harmful effects. Antioxidants constitute one of the defense systems used to neutralize pro-oxidants. Since pro-oxidants and antioxidants are found ubiquitously in nature, pro-and antioxidant effects of individual compounds and of mixtures receive much attention in scientific research. A major bottleneck in these studies, however, is the identification of the individual pro-oxidants and antioxidants in mixtures. Here, we describe the development and validation of an on-line post-column biochemical detection system for ROS-producing compounds and antioxidants in mixtures. Inclusion of cytochrome P450s and cytochrome P450 reductase also permitted the screening of compounds that need bioactivation to exert their ROS-producing properties. This pro-oxidant and antioxidant detection system was integrated on-line with gradient HPLC. The resulting high-resolution screening technology was able to separate mixtures of ROS-producing compounds and antioxidants, allowing each species to be characterized rapidly and sensitively.  相似文献   

7.
An on-line analysis method for the simultaneous detection and identification of radical scavenging compounds in plant extracts was developed by combining HPLC with hydrogen dioxide radical scavenging and HPLC-DAD-MS-CL system. The structural identification and activity characteristics of various constituents could be rapidly achieved by the on-line assay of UV, MS and CL in one run. In 4 species of Epimedium studied 32 compounds, including phenolic acids, 8-isopentenyl-flavonoid glycosides and flavonoid glycosides containing a ortho-hydroxyl group, were identified by comparison with authentic standards and published mass data. Among these compounds, phenolic acids and flavonoid glycosides containing an ortho-hydroxyl group could obviously inhibit CL, which suggested their strong radical scavenging activity. These four species each exhibited different active properties, which might correlate to their respective quality. The results indicated that the on-line HPLC-DAD-MS-CL system would be a potential method to rapidly and sensitively screen radical scavengers in herbal medicines, and could display an integrated fingerprint based on different detectors.  相似文献   

8.
Summary Fucose (6-deoxygalactose) is a constituent of airway mucous glycoproteins. In this paper we describe a high-throughput method for screening nasal lavage fluid samples and induced sputum samples for fucose. Fucose was released by hydrolysis with 0.5m sulfuric acid at 100°C for 4 h. After pH adjustment remaining proteins were removed by on-line dialysis. Chromatography was performed with two 300 mm×7.8 mm i.d. Bio-Rad Aminex HPX-87H columns arranged in a box-car configuration. Post-column derivatization was performed with benzamidine under alkaline conditions. Fluorescence was monitored at an excitation wavelength of 360 nm, using an optical cut-off filter of 420 nm. The limit of quantitation for fucose was 40 μm (S/N=3) in 300μL nasal lavage medium, with use of a 20-μL injection loop. Relative standard deviation (RSD) values for intra and inter assay data were below 15% and 20%, respectively, at spike levels of 635 μm l-fucose. The method was used to monitor the fucose content of human airway secretions. Presented at: 23rd International Symposium on Chromatography, London, UK, October 1–5, 2000  相似文献   

9.
The metrological effectiveness of an analytical method using the post-column reaction GC/FID system was evaluated. The SI-traceable certified reference material (CRM), the eight ester phthalates mixture standard solution, was used as a sample. We assigned specific value to n-eicosane and it was used as an internal standard. A known quantity of n-eicosane was added to the CRM, and the mixture was measured with the post-column reaction GC/FID system. Six phthalate esters were chromatographically separated and determined. The assigned values by our system are in good agreement with the certified values of the CRM, and the combined uncertainties of the measurements by the present system were better than those of the CRM. Our method is classified as a primary ratio method and the specific values of many organic compounds can be assigned very precisely by using a small number of reference materials. Also, the method can make it possible to avoid the purity determination of raw materials and directly to assign their specific values after the preparation of the standard mixture. Conclusively, this post-column reaction GC/FID system is very effective for the chemical metrology.  相似文献   

10.
Gas chromatography with mass selective detection is described as method for investigation and standardization of herbal raw materials and herbal drugs. Marker compounds and chromatographic conditions are described for some herbs.  相似文献   

11.
In this article, an efficient method was developed to screen, isolate and identify the major radical scavengers in the leaves of Olea europaea L. by DPPH‐HPLC‐DAD, HSCCC and NMR. The method of DPPH‐HPLC‐DAD was used to screen the major radical scavengers. It was found that three major constituents (A, B, C) in the extract of the leaves of O. europaea L. possessed potential antioxidant activities. In order to identify the chemical structures of those compounds, the HSCCC method with a two‐phase solvent system composed of petroleum ether–ethyl acetate–water at an optimized volume ratio of 6:600:700 (v/v/v) together with column chromatography was developed to isolate and purify the active compounds. Pure compounds A (225 mg), B (10 mg) and C (12 mg) with purities 92.6, 95.1 and 96.4%, respectively, were obtained from the crude sample (500 mg). Their structures were identified as oleuropein (A), luteolin‐7‐O‐glucoside (B) and verbascoside (C) by 1H‐NMR and 13C‐NMR. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

12.
Fourier transform infrared (FTIR) spectroscopy with attenuated total reflectance (ATR) sampling was evaluated for use in screening for adulteration in raw materials used in the formulation and manufacture of dietary supplements. ATR requires minimal-to-no sample preparation and the method runs in less than ten minutes, providing a robust, rapid screening test for a variety of possible adulterants in the raw materials of dietary supplements. Spectral comparison methods targeting structural similarities of known adulterants were developed. In this study, FTIR-ATR was used to detect the presence of known adulterants intentionally spiked into dietary ingredients, including erectile dysfunction drugs, steroids, weight loss drugs and Melamine.  相似文献   

13.
Summary Reversed-phase, HPLC methods employing post-column derivatization and fluorescence detection were developed for the determination of the peptide colistin and four aminoglycoside antibiotics in feeds. Extraction of the analytes was by sonication and shaking with dilute hydrochloric acid. Post-column derivatization was performed using orthophtaldialdehyde-2-mercaptoethanol chemistry. Assay of colistin was by using an acetonitrile-aqueous sodium sulphate-triethylammonium phosphate (pH 2.8) eluent. Aminoglycoside antibiotics:amikacin, kanamycin, gentamycin and neomycin were analyzed using a tetrahydrofuran-aqueous sodium sulphate-sodium pentanesulphonate-acetic acid mobile phase. The method was also applied to some pharmaceutical preparations. Preliminary results showed that the method can be adapted for the assay of the above antibiotics in meat and animal serum for residue and pharmacokinetic studies. Presented at: Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, September 3–5, 1997.  相似文献   

14.
A sensitive method for the post-column reaction detection of organophosphorus pesticides is described. The method relies on photolysis of the organocompounds by irradiation with a low-pressure mercury lamp (main spectral line, 254 nm) in the presence of peroxydisulfate. The resultant orthophosphate was reacted with molybdate to form molybdophosphoric acid, which subsequently reacted with thiamine to generate thiochrome. Finally, the fluorescence intensity of thiochrome was measured at 440 nm with excitation at 375 nm. Factors affecting the rate of these reactions were optimized so that its contribution to the total band-broadening was negligible.

This detection system was used for the determination of phosphate, acephate and methamidophos, which were separated on an ODS column by isocratic reversed phase chromatography with acetonitrile–water as the mobile phase. A linear relationship between analyte concentration and peak area was obtained within the range 0.016–7.0 μg ml−1 with correlation coefficients greater than 0.9995 and detection limits between 4 and 12 ng ml−1. Intra- and inter-day precision values of about 1.2% R.S.D. (n = 10) and 2.1% R.S.D. (n = 30), respectively, were obtained.

Pesticide residues below ng ml−1 levels could be determined in environmental waters when a preconcentration device was coupled on-line with the HPLC system. Detection limits as low as 0.01 ng ml−1 were achieved for only 250 ml of sample. In the analyses of vegetables and grains, the detection limit was about 1 μg kg−1.  相似文献   


15.
Various practical and theoretical considerations were examined in the creation and optimization of a high-performance liquid chromatography (HPLC)-based one-site immunometric assay. This method used an HPLC analyte analog column and post-column chemiluminescence detection. The specific analyte chosen as the model for this study was l-thyroxine (also known as T4). In this technique, a sample containing thyroxine was first combined with an excess of anti-T4 antibody Fab fragments that had earlier been conjugated with chemiluminescent acridinium ester labels. After incubation, the mixture was injected onto a column that contained immobilized T4. The amount of thyroxine in the original sample was then determined by measuring the labeled Fab fragments that appeared in the non-retained fraction, or the decrease in excess Fab fragments that were bound to and later eluted from the column. Items considered in creating this assay included the preparation of acridinium ester-labeled Fab fragments, the detection of these fragments with a post-column reactor, and the creation of a suitable immobilized analog column for capturing excess labeled Fab fragments. The final method could measure T4 in standards at clinically-relevant concentrations and provided a response within 1.5 min of sample injection, following a 20-45 min incubation with the labeled Fab fragments. Possible applications of this method include its use in clinical chemistry and the screening of proteomic or combinatorial libraries.  相似文献   

16.
建立了连续测定NO2-和NO3-的柱后在线衍生结合流动注射光度分析体系.阴离子交换柱(HPIC-AS3)分离水样中的NO2-和NO3-,洗脱液依次将NO2-和NO3-洗脱流经镀铜镉还原柱,NO3-在线还原为NO2-,与对氨基苯磺酸溶液和N-(1-萘基)-乙二胺溶液合并,在λmax=500 nm处对NO2-和NO3-产生的红色染料进行光度连续检测.NO2-和NO3-的线性范围分别为0.01~1.0mg/L和0.02~2.0 mg/L,检出限分别为0.004和0.008 ng/L.方法用于雨水、湖水和自来水中痕量NO2-和NO3-的同时连续测定.  相似文献   

17.
A microfluidic system incorporating chemiluminescence detection is reported as a new tool for measuring antioxidant capacity. The detection is based on a peroxyoxalate chemiluminescence (PO-CL) assay with 9,10-bis-(phenylethynyl)anthracene (BPEA) as the fluorescent probe and hydrogen peroxide as the oxidant. Antioxidant plugs injected into the hydrogen peroxide stream result in inhibition of the CL emission which can be quantified and correlated with antioxidant capacity. The PO-CL assay is performed in 800-μm-wide and 800-μm-deep microchannels on a poly(dimethylsiloxane) (PDMS) microchip. Controlled injection of the antioxidant plugs is performed through an injection valve. Of the plant-food based antioxidants tested, β-carotene was found to be the most efficient hydrogen peroxide scavenger (SA HP of 3.27 × 10−3 μmol−1 L), followed by α-tocopherol (SA HP of 2.36 × 10−3 μmol−1 L) and quercetin (SA HP of 0.31 × 10−3 μmol−1 L). Although the method is inherently simple and rapid, excellent analytical performance is afforded in terms of sensitivity, dynamic range, and precision, with RSD values typically below 1.5%. We expect our microfluidic devices to be used for in-the-field antioxidant capacity screening of plant-sourced food and pharmaceutical supplements. Figure Assembled PDMS microchip sandwiched between two glass plates with the top plate containing capillary reservoirs  相似文献   

18.
Cefepime is a new parenteral cephalosporin that has been described as a fourth-generation, broad-spectrum antibiotic. This paper reports the development and in-house validation of an agar diffusion bioassay using a cylinder-plate method for the determination of cefepime in powder for injection. The validation performed yielded good results in terms of linearity, precision, accuracy, and robustness. The assay is based on the inhibitory effect of cefepime upon the strain of Micrococcus luteus ATCC 10240 used as the test microorganism. The results of assays were treated statistically by analysis of variance (ANOVA) and were found to be linear (r = 0.99993) in the selected range of 8.0-32.0 microg/mL; precise [repeatability: relative standard deviation (RSD) = 1.39%, intermediate precision: between-day RSD = 1.77%, and between-analyst RSD = 1.97%] and accurate. Comparison of bioassay and liquid chromatography by ANOVA showed no significant difference between methodologies. The results demonstrated the validity of the proposed bioassay, which is a simple and useful alternative methodology for cefepime determination in routine quality control.  相似文献   

19.
Ceftazidime (CFZ) is a broad spectrum parenteral beta-lactam antibiotic of the cephalosporin family. This paper reports the development and validation of an agar diffusion microbiological assay using the cylinder-plate method for determination of CFZ in powder for injection. The validation carried out yielded good results in terms of linearity, precision, accuracy, selectivity, and robustness. The assay is based on the inhibitory effect of CFZ upon the strain of Pseudomonas aeruginosa ATCC 27853 used as the test microorganism. The results of the assays were treated statistically by analysis of variance and were found to be linear (correlation coefficient = 0.999998) in the selected range of 8.0-32.0 microg/mL; precise [repeatability: relative standard deviation (RSD) = 1.11%; intermediate precision: between-day RSD = 1.37% and between-analyst RSD = 1.41%]; and accurate. The selectivity of the bioassay was evaluated by analysis of degraded samples at 50 degrees C, and the results were compared with a pharmacopeial liquid chromatographic method at the time 0, 24, and 48 h. The results demonstrated the validity of the proposed bioassay, which allows reliable quantitation of CFZ in pharmaceutical samples and can be used as a useful alternative methodology for CFZ analysis in routine quality control.  相似文献   

20.
A detection scheme based on the Post-column addition of terbium followed by sensitized luminescence detection has been developed. Two model Compounds- saliculic acid and diflunisa- were separated by capillary electophoresis in an alkaline phosphate buffer. A Solution containing terbium and CTAB was added post-column via a “home-built” reactor resulting in the rapid fromation of the strongly luminescent terbium-salicylic acid and terbium-diflunisal complexes in a reaction capillary. Following complexationn in the reaction capillarty, the 325 nm line from a HeCd laser was used to excite the analytes which efficiently transfer their energy to terebium. Resuulant luminescence of terebium was liner of 2 orders of magnitude. This novel and practical system enables the detection of micromolar concentrations of diflunisal and salicylic acid- a 10 fold improvement over UV absorbance detection in the same system. Post-column addition of terbium also eliminates the problems associated with strong adsorption of the lanthanide ion to the silica walls of the separation capillary and the formation of metal-ligand complexes with different coordination numbers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号