首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We present an isotopic-dilution direct injection reversed-phase liquid chromatography–tandem mass spectrometry method for the simultaneous determination of 23 drugs of abuse, drug metabolites, and human-use markers in municipal wastewater. The method places particular emphasis on cocaine; it includes 11 of its metabolites to facilitate assessment of routes of administration and to enhance the accuracy of estimates of cocaine consumption. Four opioids (6-acetylmorphine, morphine, hydrocodone, and oxycodone) are also included, along with five phenylamine drugs (amphetamine, methamphetamine, 3,4-methylenedioxy-methamphetamine, methylbenzodioxolyl-butanamine, and 3,4-methylenedioxy-N-ethylamphetamine) and two human-use markers (cotinine and creatinine). The method is sufficiently sensitive to directly quantify (without preconcentration) 18 analytes in wastewater at concentrations less than 50 ng/L. We also present a modified version of this method that incorporates solid-phase extraction to further enhance sensitivity. The method includes a confirmatory LC separation (selected by evaluating 13 unique chromatographic phases) that has been evaluated using National Institute of Standards and Technology Standard Reference Material 1511 Multi-Drugs of Abuse in Freeze-Dried Urine. Seven analytes (ecgonine methyl ester, ecgonine ethyl ester, anhydroecgonine methyl ester, m-hydroxybenzoylecgonine, p-hydroxybenzoyl-ecgonine, ecgonine, and anhydroecgonine) were detected for the first time in a wastewater sample.  相似文献   

2.
A sensitive and specific method is presented to simultaneously quantify methadone, heroin, cocaine and metabolites in sweat. Drugs were eluted from sweat patches with sodium acetate buffer, followed by SPE and quantification by GC/MS with electron impact ionization and selected ion monitoring. Daily calibration for anhydroecgonine methyl ester, ecgonine methyl ester, cocaine, benzoylecgonine (BE), codeine, morphine, 6-acetylcodeine, 6-acetylmorphine (6AM), heroin (5-1000 ng/patch) and methadone (10-1000 ng/patch) achieved determination coefficients of >0.995, and calibrators quantified to within +/-20% of the target concentrations. Extended calibration curves (1000-10,000 ng/patch) were constructed for methadone, cocaine, BE and 6AM by modifying injection techniques. Within (N = 5) and between-run (N = 20) imprecisions were calculated at six control levels across the dynamic ranges with coefficients of variation of <6.5%. Accuracies at these concentrations were +/-11.9% of target. Heroin hydrolysis during specimen processing was <11%. This novel assay offers effective monitoring of drug exposure during drug treatment, workplace and criminal justice monitoring programs.  相似文献   

3.
When cocaine is smoked, a pyrolytic product, methyl ecgonidine (anhydroecgonine methyl ester), is also consumed with the cocaine. The amount of methyl ecgonidine formed depends on the pyrolytic conditions and composition of the illicit cocaine. This procedure describes detection of cocaine and 10 metabolites--cocaethylene, nor-cocaine, nor-cocaethylene, methyl ecgonine, ethyl ecgonine, benzoylecgonine, nor-benzoylecgonine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine and ecgonine--in blood and urine. In addition, the detection of pyrolytic methyl ecgonidine and three metabolites--ecgonidine (anhydroecgonine), ethyl ecgonidine (anhydroecgonine ethyl ester) and nor-ecgonidine (nor-anhydroecgonine)--are included. The newly described metabolites, ethyl ecgonidine and nor-ecgonidine, were synthesized and characterized by gas chromatography-mass spectrometry (GC-MS). All 15 compounds were extracted from 3 mL of blood or urine by solid-phase extraction and identified by a GC-MS method. The overall recoveries were 49% for methyl ecgonine, 35% for ethyl ecgonine, 29% for ecgonine and more than 83% for all other drugs. The limits of detection were between 0.5 and 4.0 ng/mL except for ecgonine, which was 16 ng/mL. Linearity for each analyte was established and in all cases correlation coefficients were 0.9985-1.0000. The procedure was applied to examine the concentration profiles of analytes of interest in post-mortem (PM) blood and urine, and in urine collected from living individuals (LV). These specimens previously were shown to be positive for the cocaine metabolite, benzoylecgonine. Ecgonidine, the major metabolite of methyl ecgonidine, was present in 77% of PM and 88% of the LV specimens, indicating smoking as the major route of cocaine administration. The new pyrolytic metabolites, ethyl ecgonidine and nor-ecgonidine, were present in smaller amounts. The urine concentrations of nor-ecgonidine were 0-163 ng/mL in LV and 0-75 ng/mL in PM specimens. Ethyl ecgonidine was found only in PM urine at concentrations 0-39 ng/mL. Ethanol-related cocaine metabolites, ethyl ecgonine or cocaethylene, were present in 69% of PM and 53% of cocaine-positive LV specimens, implying alcohol consumption with cocaine use. The four major metabolites of cocaine--benzoylecgonine, ecgonine, nor-benzoylecgonine and methyl ecgonine--constituted approximately 88 and 97% of all metabolites in PM and LV specimens, respectively. The concentrations of nor-cocaine and nor-cocaethylene were consistently the lowest of all cocaine metabolites. At benzoylecgonine concentrations below 100 ng/mL, ecgonine was present at the highest concentrations. In 20 urine specimens, benzoylecgonine and ecgonine median concentrations (range) were 54 (0-47) and 418 ng/mL (95-684), respectively. Therefore, detection of ecgonine is advantageous when benzoylecgonine concentrations are below 100 ng/mL.  相似文献   

4.
LC-MS/MS methods for the quantification of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, 6-acetylmorphine, cocaine, benzoylecgonine, ecgonine methyl ester, hydroxybenzoylecgonine, cocaethylene, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine (MDMA), methadone, and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine in human placenta and umbilical cord were developed and validated. Specimens (1?±?0.02 g) were homogenized with the Ultra-Turrax T8 disperser and centrifuged, and the supernatant was submitted to solid-phase extraction with Oasis MCX cartridges. Chromatographic separation was performed using an Atlantis T3 analytical column (100?×?2.1 mm, 3 μm) and a gradient of 0.1 % formic acid and acetonitrile. Selectivity was verified in 10 different blank specimens. The method was linear from 1–5 to 100–500 ng/g, depending on the analyte. Limits of detection and quantification ranged from 0.5 to 2.5 ng/g and 1 to 5 ng/g, respectively. Method imprecision was ≤15.3 %, except for MDMA at low quality control (18.1 %); accuracy, 87.1 to 114 %; extraction efficiency, 16.3 to 154.0 % (%CV?=?1.8-39.4 %); matrix effect, ?75.7 to 449.9 % (%CV?=?3.5–50 %); and process efficiency, 8.7 to 316.0 %. The method was applied to authentic placenta and umbilical cord specimens from drug-user pregnant women.  相似文献   

5.
A simple, quick and inexpensive screening method for cocaine and cocaine metabolites has been developed. Drug extraction was achieved using the relatively new technique of solvent microextraction (SME). Complete analysis is achieved in 13 min, using, a 6-min extraction with a 2-microl drop followed by separation on a gas chromatograph. The developed procedure was tested as a screening method for cocaine and cocaine metabolites in spiked urine samples. Using SME, concentrations as low as 0.125 microg ml(-1) of cocaine, ecgonine methyl ester, cocaethylene and anhydroecgonine methyl ester were measurable with relative standard deviation values averaging 9.0%.  相似文献   

6.
A validated method for simultaneous LCMSMS quantification of nicotine, cocaine, 6-acetylmorphine (6AM), codeine, and metabolites in 100 mg fetal human brain was developed and validated. After homogenization and solid-phase extraction, analytes were resolved on a Hydro-RP analytical column with gradient elution. Empirically determined linearity was from 5–5,000 pg/mg for cocaine and benzoylecgonine (BE), 25–5,000 pg/mg for cotinine, ecgonine methyl ester (EME) and 6AM, 50-5000 pg/mg for trans-3-hydroxycotinine (OH-cotinine) and codeine, and 250–5,000 pg/mg for nicotine. Potential endogenous and exogenous interferences were resolved. Intra- and inter-assay analytical recoveries were ≥92%, intra- and inter-day and total assay imprecision were ≤14% RSD and extraction efficiencies were ≥67.2% with ≤83% matrix effect. Method applicability was demonstrated with a postmortem fetal brain containing 40 pg/mg cotinine, 65 pg/mg OH-cotinine, 13 pg/mg cocaine, 34 pg/mg EME, and 525 pg/mg BE. This validated method is useful for determination of nicotine, opioid, and cocaine biomarkers in brain.  相似文献   

7.
Determination of drugs of abuse in blood is of great importance in clinical and forensic toxicology. This review describes procedures for detection of the following drugs of abuse and their metabolites in whole blood, plasma or serum: Δ9-tetrahydrocannabinol, 11-hydroxy-Δ9-tetrahydrocannabinol, 11-nor-9-carboxy-Δ9-tetrahydrocannabinol, 11-nor-9-carboxy-Δ9-tetrahydrocannabinol glucuronide, heroin, 6-monoacetylmorphine, morphine, morphine-6-glucuronide, morphine-3-glucuronide, codeine, amphetamine, methamphetamine, 3,4-methylenedioxymethamphetamine, N-ethyl-3,4-methylenedioxyamphetamine, 3,4-methylenedioxyamphetamine, cocaine, benzoylecgonine, ecgonine methyl ester, cocaethylene, other cocaine metabolites or pyrolysis products (norcocaine, norcocaethylene, norbenzoylecgonine, m-hydroxycocaine, p-hydroxycocaine, m-hydroxybenzoylecgonine, p-hydroxybenzoylecgonine, ethyl ecgonine, ecgonine, anhydroecgonine methyl ester, anhydroecgonine ethyl ester, anhydroecgonine, noranhydroecgonine, N-hydroxynorcocaine, cocaine N-oxide, anhydroecgonine methyl ester N-oxide). Metabolites and degradation products which are recommended to be monitored for assessment in clinical or forensic toxicology are mentioned. Papers written in English between 2002 and the beginning of 2007 are reviewed. Analytical methods are assessed for their suitability in forensic toxicology, where special requirements have to be met. For many of the analytes sensitive immunological methods for screening are available. Screening and confirmation is mostly done by gas chromatography (GC)–mass spectrometry (MS) or liquid chromatography (LC)–MS(/MS) procedures. Basic information about the biosample assayed, internal standard, workup, GC or LC column and mobile phase, detection mode, and validation data for each procedure is summarized in two tables to facilitate the selection of a method suitable for a specific analytic problem.  相似文献   

8.
Ecgonine is suggested to be a promising marker of cocaine (COC) ingestion. A combined mass spectrometry (MS) and tandem MS (MS/MS) method was developed to simultaneously determine ecgonine and seven other metabolites of cocaine in human urine and whole blood with ultra-high-pressure liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. The compounds were extracted from as little as 100 μL of sample by solid-phase extraction with a 96-well μElution solid-phase extraction plate. The protonated molecules or fragment ions at accurate mass acquired in MS mode were used to quantify specific analytes, following by dedicated MS/MS identification. The assay was linear in the range from 5 to 50-100 ng/mL for urine samples, except for ecgonine methyl ester (10-200 ng/mL) and ecgonine (40-400 ng/mL), and was linear from 1-2 to 50 ng/mL for whole blood samples, except for ecgonine methyl ester (20-1,000 ng/mL) and ecgonine (40-2,000 ng/mL). The correlation coefficients were all greater than 0.99. The limits of detection ranged from 0.2 to 16 ng/mL, and the lower limits of quantification ranged from 1 to 40 ng/mL. The repeatability and intermediate precision were 18.1 % or less. The accuracy was in the range from 80.0 to 122.9 %, process efficiencies were in the range from 8.6 to 177.4 %, matrix effects were in the range from 28.7 to 171.0 %, and extraction recoveries were in the range from 41.0 to 114.3 %, except for ecgonine (12.8 % and 9.3 % at low and high concentrations, respectively). This method was highly sensitive in comparison with previously published methods. The validated method was successfully applied to the analysis of real samples derived from forensic cases, and the results verified that, on the basis of data from four positive samples, ecgonine is a promising marker of cocaine ingestion.
Figure
Procedure for the determination of ecgonine and seven other cocaine metabolites in human urine and whole blood using a combined mass spectrometry and tandem MS method aIer the solid‐phase extraction of the anaytes  相似文献   

9.
A method for simultaneous determination of buprenorphine (BUP), norbuprenorphine (NBUP), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine, benzoylecgonine (BE), ecgonine methyl ester (EME), anhydroecgonine methyl ester (AEME), morphine, codeine, 6-acetylmorphine (6AM), heroin, 6-acetylcodeine (6AC), nicotine, cotinine, and trans-3′-hydroxycotinine (OH-cotinine) by liquid chromatography tandem mass spectrometry in oral fluid (OF) was developed and extensively validated. Acetonitrile (800 μL) and OF (250 μL) were added to a 96-well Isolute-PPT+protein precipitation plate. Reverse-phase separation was achieved in 16 min and quantification was performed by multiple reaction monitoring. The assay was linear from 0.5 or 1 to 500 μg/L. Intraday, interday, and total imprecision were less than 13% (n?=?20), analytical recovery was 92–114% (n?=?20), extraction efficiencies were more than 77% (n?=?5), and process efficiencies were more than 45% (n?=?5). Although ion suppression was detected for EME, cocaine, morphine, 6AC, and heroin (less than 56%) and enhancement was detected for BE and nicotine (less than 316%), deuterated internal standards compensated for these effects. The method was sensitive (limit of detection 0.2–0.8 μg/L) and specific (no interferences) except that 3-hydroxy-4-methoxyamphetamine interfered with AEME. No carryover was detected, and all analytes were stable for 24 h at 22 °C, for 72 h at 4 °C, and after three freeze–thaw cycles, except cocaine, 6AC, and heroin (22–97% loss). The method was applied to 41 OF specimens collected throughout pregnancy with a Salivette® OF collection device from an opioid-dependent BUP-maintained pregnant woman. BUP ranged from 0 to 7,400 μg/L, NBUP from 0 to 71 μg/L, methadone from 0 to 3 μg/L, nicotine from 32 to 5,020 μg/L, cotinine from 125 to 508 μg/L, OH-cotinine from 11 to 51 μg/L, cocaine from 0 to 419 μg/L, BE from 0 to 351 μg/L, EME from 0 to 286 μg/L, AEME from 0 to 7 μg/L, morphine from 0 to 22 μg/L, codeine from 0 to 1 μg/L, 6AM from 0 to 4 μg/L, and heroin from 0 to 2 μg/L. All specimens tested negative for EDDP and 6AC. This method permits a fast and simultaneous quantification of 16 drugs and metabolites in OF, with good selectivity and sensitivity.  相似文献   

10.
A liquid chromatography tandem mass spectrometry method for buprenorphine (BUP), norbuprenorphine (NBUP), methadone, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), cocaine, benzoylecgonine, ecgonine methyl ester (EME), morphine, codeine, 6-acetylmorphine, heroin, 6-acetylcodeine, cotinine, and trans-3′-hydroxycotinine quantification in sweat was developed and comprehensively validated. Sweat patches were mixed with 6 mL acetate buffer at pH 4.5, and supernatant extracted with Strata-XC-cartridges. Reverse-phase separation was achieved with a gradient mobile phase of 0.1% formic acid and acetonitrile in 15 min. Quantification was achieved by multiple reaction monitoring of two transitions per compound. The assay was a linear 1–1,000 ng/patch, except EME 5–1,000 ng/patch. Intra-, inter-day and total imprecision were <10.1%CV, analytical recovery 87.2–107.7%, extraction efficiency 35.3–160.9%, and process efficiency 25.5–91.7%. Ion suppression was detected for EME (−63.3%) and EDDP (−60.4%), and enhancement for NBUP (42.6%). Deuterated internal standards compensated for these effects. No carryover was detected, and all analytes were stable for 24 h at 22 °C, 72 h at 4 °C, and after three freeze/thaw cycles. The method was applied to weekly sweat patches from an opioid-dependent BUP-maintained pregnant woman; 75.0% of sweat patches were positive for BUP, 93.8% for cocaine, 37.5% for opiates, 6.3% for methadone and all for tobacco biomarkers. This method permits a fast and simultaneous quantification of 14 drugs and metabolites in sweat patches, with good selectivity and sensitivity.  相似文献   

11.
A solid-phase extraction method was developed for the extraction of first-day meconium samples from premature infants of cocaine-dependent mothers. Extracts were analysed by high-performance liquid chromatography and gas chromatography-mass spectrometry for cocaine and its metabolites. Control stools showed no drug. Meconium from cocaine-dependent mothers showed cocaine in the range 0.1-0.78 micrograms/g. Benzoylecgonine, ecgonine and ecognine methyl ester were not present in the samples, which suggests that the metabolism of cocaine in the premature neonate is limited.  相似文献   

12.
Summary Quantitative extraction studies from urine were carried out by addition of cocaine, benzoylecgonine, ecgonine methyl ester and ecgonine to urine samples. After hydrolysis to ecgonine the compounds were analyzed together. Ecgonine was isolated by a cation-exchange resin and purified by an anion-exchange resin. The quantitative determination was performed by GC after silylation with MSTFA. The recovery was 77% at a concentration of 150 g ecgonine/ml urine. A qualitative determination of ecgonine by GC/MS was possible up to the detection limit of 20 ng/ ml. The method can be applied for the detection of cocaine abuse.
Extraktion, quantitative gas-chromatographische Bestimmung und gas-chromatographischer massenspektrometrischer Nachweis von Ecgonin zur Identifizierung von Cocain und seinen Metaboliten in Urin
Zusammenfassung Es wurden quantitative Untersuchungen zur Extraktion von Urin durchgeführt, dem Cocain, Benzoylecgonin, Ecgoninmethylester und Ecgonin zugesetzt wurden. Die Summe dieser Verbindungen kann über eine vorgeschaltete Hydrolyse zu Ecgonin indirekt bestimmt werden. Nach Hydrolyse wird Ecgonin an einem Kationenaustauscher isoliert und der Extrakt an einem Anionenaustauscher gereinigt. Die quantitative Bestimmung erfolgt gaschromatographisch nach Silylierung mit MSTFA. Dabei beträgt die Wiederfindungsrate 77% bei Konzentrationen von 150 g Ecgonin/ml Urin. Der qualitative Nachweis von Ecgonin durch GC/MS ist bis zu einer Nachweisgrenze von 20 ng/ml möglich. Damit eignet sich die Methode zum Nachweis einer Cocain-Einnahme im Urin.


From the dissertation by U. Zerell, University of Bonn, 1986 (in preparation)  相似文献   

13.
A combined assay is described for cocaine and its major metabolites, benzoylecgonine and ecgonine methyl ester. The method uses electrochemical and ultraviolet detectors in series. A non-silica column is used with high-pH mobile phase. The three compounds are completely separated from other cocaine metabolites. The assay has been suitable for pharmacokinetic studies of cocaine disposition in animal studies.  相似文献   

14.
A method for the simultaneous quantification of 20 cocaine, amphetamine, opiate, and nicotine analytes in meconium, the first neonatal feces, by liquid chromatography tandem mass spectrometry was developed and validated. Specimen preparation included methanol homogenization and solid phase extraction. Two injections were required to achieve sufficient sensitivity and linear dynamic range. Linearity ranged from 0.5–25 up to 500 ng/g (250 ng/g p-hydroxymethamphetamine), and correlation coefficients were >0.996. Imprecision was <10.0% CV, analytical recovery 85.5–123.1%, and extraction efficiencies >46.7% at three concentrations across the linear range. Despite significant matrix effects of −305.7–40.7%, effects were similar for native and deuterated analytes. No carryover, endogenous or exogenous interferences were observed, with analyte stability at room temperature, 4 °C, and −20 °C and on the autosampler >70%, except for 6-acetylmorphine, hydrocodone, oxycodone, and morphine. Method applicability was demonstrated by analyzing meconium from drug-exposed neonates.  相似文献   

15.
One aspect of immunopharmacotherapy for cocaine abuse involves the use of a catalytic monoclonal antibody (mAb) to degrade cocaine via hydrolysis of the benzoate ester. A cocaine benzoylthio ester analogue provides a means to implement high-throughput selection strategies to potentially isolate mAbs with high activity. The required analogue was synthesized starting from (-)-cocaine hydrochloride and possessed the cocaine absolute configuration. Key points in the preparation were the introduction of the sulfur atom at C-3 via a bromomagnesium thiolate addition to the exo face of anhydroecgonine, separation of C-2 diastereomers, recycling of a C-2 thio ester byproduct, and formation of the necessary C-2 methyl and C-3 benzoylthio esters. Effects resulting from the lower electronegativity and greater hydrophobicity of sulfur compared to oxygen were observed. These characteristics could result in interesting drug properties. Furthermore, the analogue was found to be a substrate for catalytic mAbs that hydrolyze cocaine as monitored by HPLC and also spectrophotometry by coupling cleavage of the benzoylthio ester to the disulfide exchange with Ellman's reagent. Screening antibody libraries with the new cocaine analogue using the spectroscopic assay provides an avenue for the high-throughput identification of catalysts that efficiently breakdown cocaine.  相似文献   

16.
We report a sample pretreatment approach for the analysis of total cocaine residues in wastewater that eliminates the need for two key assumptions often made in estimating cocaine utilization from measurement of its benzoylecgonine metabolite: that benzoylecgonine is neither degraded nor generated during transport in a sewer system, and that it is excreted as a constant fraction of cocaine ingested. By adding NaOH and incubating samples at 55 °C, cocaine and its principal metabolites are efficiently hydrolyzed into ecgonine, anhydroecgonine, and norecgonine. Ecgonine, estimated to represent between 37% and 90% (on a molar basis) of cocaine residues, can be directly determined (without preconcentration via solid-phase extraction (SPE)) by reversed-phase (RP) or hydrophilic interaction liquid chromatography–tandem mass spectrometry (LC/MS/MS). If samples are subjected to SPE, anhydroecgonine can also be determined; this metabolite (and its precursors) represents ≈7% of urinary cocaine residues (based on spot collections from living individuals). Although a reference standard for norecgonine is not commercially available, such nortropanes are also a minor fraction (up to 2%) of urinary cocaine residues. The stability of two human markers (cotinine and creatinine) to the hydrolysis procedure was also investigated. Results obtained by applying the hydrolysis approach for the analysis of total cocaine in an untreated municipal wastewater sample (obtained from Baltimore, MD) were generally in excellent agreement with those obtained from split samples analyzed using a more comprehensive solid-phase extraction RPLC/MS/MS method as described in our previous work. In particular, total tropane-based cocaine residues were found to be hydrolyzed to ecgonine with 98–99% efficiency.  相似文献   

17.
A microfluidic chip based nano-HPLC coupled to tandem mass spectrometry (nano-HPLC-Chip-MS/MS) has been developed for simultaneous measurement of abused drugs and metabolites: cocaine, benzoylecgonine, cocaethylene, norcocaine, morphine, codeine, 6-acetylmorphine, phencyclidine, amphetamine, methamphetamine, MDMA, MDA, MDEA, and methadone in the hair of drug abusers. The microfluidic chip was fabricated by laminating polyimide films and it integrated an enrichment column, an analytical column and a nanospray tip. Drugs were extracted from hairs by sonication, and the chromatographic separation was achieved in 15 min. The drug identification and quantification criteria were fulfilled by the triple quardropule tandem mass spectrometry. The linear regression analysis was calibrated by deuterated internal standards with all of the R 2 at least over 0.993. The limit of detection (LOD) and the limit of quantification (LOQ) were from 0.1 to 0.75 and 0.2 to 1.25 pg/mg, respectively. The validation parameters including selectivity, accuracy, precision, stability, and matrix effect were also evaluated here. In conclusion, the developed sample preparation method coupled with the nano-HPLC-Chip-MS/MS method was able to reveal the presence of drugs in hairs from the drug abusers, with the enhanced sensitivity, compared with the conventional HPLC-MS/MS.  相似文献   

18.
《Analytical letters》2012,45(16):2572-2581
Pharmaceutical preparations of heroin and cocaine more than seventy years old were analyzed using RP-HPLC. The composition of mobile phase was optimized. The components were identified by MS2 or MS3, and the APPI fragmentation mechanisms of compounds found were proposed. The sample of heroin hydrochloride injection solution consists of 96.1% morphine and 3.9% of codeine. The sample of cocaine hydrochloride injection solution consists of 26.9% cocaine, 31.5% benzoylecgonine, 17.4% ecgonine, and 24.2% ecgonine methyl ester.  相似文献   

19.
Microextraction by packed sorbent (MEPS) has been evaluated for fast screening of drugs of abuse with mass spectrometric detection. In this study, C8 (octyl-silica, useful for nonpolar to moderately polar compounds), ENV+ (hydroxylated polystyrene-divinylbenzene copolymer, for extraction of aliphatic and aromatic polar compounds), Oasis MCX (sulfonic-poly(divinylbenzene-co-N-polyvinyl-pyrrolidone) copolymer), and Clean Screen DAU (mixed mode, ion exchanger for acidic and basic compounds) were used as sorbents for the MEPS. The focus was on fast extraction and preconcentration of the drugs with rapid analysis using a time-of-flight (TOF) mass spectrometer as the detector with direct analysis in a real-time (DART) source. The combination of an analysis time of less than 1 min and accurate mass of the first monoisotopic peak of the analyte and the relative abundances of the peaks in the isotopic clusters provided reliable information for identification. Furthermore, the study sought to demonstrate that it is possible to quantify the analyte of interest using a DART source when an internal standard is used. Of all the sorbents used in the study, Clean Screen DAU performed best for extraction of the analytes from urine. Using Clean Screen DAU to extract spiked samples containing the drugs, linearity was demonstrated for ecgonine methyl ester, benzoylecgonine, cocaine, and cocaethylene with average ranges of: 65–910, 75–1100, 95–1200, and 75–1100 ng/mL (n = 5), respectively. The limits of detection (LOD) for ecgonine methyl ester, benzoylecgonine, cocaine, and cocaethylene were 22. 9 ng/mL, 23. 7 ng/mL, 4. 0 ng/mL, and 9.8 ng/mL respectively, using a signal-to-noise ratio of 3:1.  相似文献   

20.
A method is described for extraction of the cocaine metabolite benzoylecgonine, conversion to the butyl ester derivative and gas chromatographic analysis using packed or capillary columns. Using a capillary column, cocaine and benzoylecgonine may be determined simultaneously. The extraction scheme has been designed to facilitate processing of large numbers of samples generated in pharmacokinetic studies. Structural analogues, m-toluylecgonine and m-toluylecgonine methyl ester, are used as internal standards. Concentrations as low as 10 ng/ml in 1-ml samples of plasma or urine are readily determined. Between-run coefficients of variation were 1.01% for cocaine and 4.18% for benzoylecgonine for concentrations of 75 and 350 ng/ml, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号