共查询到20条相似文献,搜索用时 827 毫秒
1.
Proficiency testing as a means of external quality assessment plays the role of independent evidence of laboratories’ performance.
To enable laboratories to fulfil the requirements stated in legislation, methodology for evaluation of laboratories’ performance
in proficiency testing schemes should incorporate principles of measurement results which are fit for intended use and incorporate
evaluation of laboratories’ performances based on independent reference value. A proficiency testing scheme was designed to
support Drinking Water Directive (98/83/EC) specifically. The methodology for performance evaluation, which takes into account
a “fitness for purpose”-based standard deviation for proficiency assessment, is proposed and discussed in terms of requirements
of the Drinking Water Directive. A ζ′-score, modified by application of target uncertainty was developed in a way that fulfils requirements defined in the legislation.
As an illustration, results are reported for nitrate concentration in water. The approach presented can also be applied to
other fields of measurements. 相似文献
2.
A. V. Harms 《Accreditation and quality assurance》2009,14(6):307-311
A novel graphical method (‘Kiri plots’) for the presentation of proficiency test exercise results is presented. The Kiri plot
visualises the evaluation of the proficiency test results based on three statistical tests (the z score, the zeta score and the relative uncertainty outlier test) by defining six zones including a central “in agreement”
zone. 相似文献
3.
A study of the performance of different uncertainty evaluation strategies among 163 voluntary respondents from food proficiency
schemes is presented. Strategies included use of: single-laboratory validation data, quality control data, past proficiency
testing data, reproducibility data, a measurement equation and the dispersion of replicate observations on the test material.
Most performed reasonably well, but the dispersion of replicate observations underestimated uncertainty by a factor of approximately
3. Intended compliance with accreditation requirements was associated with significantly improved uncertainty evaluation performance,
while intended compliance with the ISO “Guide to the expression of uncertainty in measurement” had no significant effect.
Substituting estimates based on the Horwitz or Horwitz–Thompson models or on PT target standard deviation for the respondents’
own estimates of uncertainty led to a marked reduction in poor zeta scores and significant improvement in dispersion of zeta
scores. 相似文献
4.
Petras Serapinas 《Accreditation and quality assurance》2007,12(11):569-574
Good correspondence between evaluations of the proficiency testing data for water measurements according to different scoring
schemes was found as a result of implementation of the measurement quality according to the target uncertainty defined in
the Drinking Water Directive. The accuracy of the evaluation is determined by the uncertainty of the assigned value, and this
uncertainty should be in correspondence with the target uncertainty. Modification of the zeta-score by the thorough application of the target uncertainty is presented. It is convenient for generalised presentation of
the proficiency testing data. The allowed bias is included as a linear term on the measured value scale, as it is treated
in uncertainty analysis. The importance of implementation of the target measurement uncertainty in other fields of the routine
measurements is indicated. 相似文献
5.
Anita Schmidt 《Accreditation and quality assurance》2001,6(6):277-278
The 5th Eurolab Symposium on 4th and 5th October in Edinburgh was the highlight event of Eurolab in 2000, Eurolab’s 10th anniversary
year. Under the title: ”Confidence in Testing Services – new expectations, new rules, new challenges” it reflected recent
changes and developments in the laboratory scene and focussed on new tasks and challenges. The most essential changes for
laboratories are connected with the new standard ISO/IEC 17025 ”General requirements for the competence of testing and calibration
laboratories”. Keywords in this respect are uncertainty of measurement and traceability to SI units, requirements on personnel,
proficiency testing, customer orientation, and management systems. 相似文献
6.
This paper briefly summarises the current situation for proficiency testing (PT) in China, outlines the policy for PT of China’s
national accreditation committee for laboratories (CNACL), and exemplifies activities of the CNACL’s metal working group.
Received: 9 December 2000 Accepted: 14 December 2000 相似文献
7.
Marc Priel 《Accreditation and quality assurance》2009,14(5):235-241
Since the advent of the Guide to the expression of Uncertainty in Measurement (GUM) in 1995 laying the principles of uncertainty
evaluation numerous projects have been carried out to develop alternative practical methods that are easier to implement namely
when it is impossible to model the measurement process for technical or economical aspects. In this paper, the author presents
the recent evolution of measurement uncertainty evaluation methods. The evaluation of measurement uncertainty can be presented
according to two axes based on intralaboratory and interlaboratory approaches. The intralaboratory approach includes “the
modelling approach” (application of the procedure described in section 8 of the GUM, known as GUM uncertainty framework) and
“the single laboratory validation approach”. The interlaboratory approaches are based on collaborative studies and they are
respectively named “interlaboratory validation approach” and “proficiency testing approach”. 相似文献
8.
Adriaan M. H. van der Veen 《Accreditation and quality assurance》2001,6(4-5):160-163
The evaluation of measurement uncertainty, and that of uncertainty statements of participating laboratories will be a challenge
to be met in the coming years. The publication of ISO 17025 has led to the situation that testing laboratories should, to
a certain extent, meet the same requirements regarding measurement uncertainty and traceability. As a consequence, proficiency
test organizers should deal with the issues measurement uncertainty and traceability as well. Two common statistical models
used in proficiency testing are revisited to explore the options to include the evaluation of the measurement uncertainty
of the PTRV (proficiency test reference value). Furthermore, the use of this PTRV and its uncertainty estimate for assessing
the uncertainty statements of the participants for the two models will be discussed. It is concluded that in analogy to Key
Comparisons it is feasible to implement proficiency tests in such a way, that the new requirements can be met.
Received: 29 September 2000 Accepted: 3 December 2000 相似文献
9.
The two most important concepts in metrology are certainly “traceability to standards” and “measurement uncertainty evaluation”.
So far the questions related to these concepts have been reasonably solved in the metrology of “classical quantities”, but
for the introduction of metrological concepts in new fields, such as chemistry and biology, a lot of problems remain and must
be solved in order to support international arrangements. In this presentation, the authors want to develop the strategy implemented
at Laboratoire national de métrologie et d’essais (LNE) in metrology in chemistry and biology. The strategy is based on: (1)
pure solutions for calibration of analytical instruments, (2) use of certified reference materials (matrix reference materials),
and (3) participation to proficiency testing schemes. Examples will be presented in organic and inorganic chemistry. For laboratory
medicine, proficiency testing providers play an important role in the organization of External Quality Assessment Schemes.
For the time being, the reference value or the assigned value of the comparison is calculated with the results obtained by
the participants. This assigned value is not often traceable to SI units. One of the methods suggested by LNE is to ensure
the metrological traceability to SI units of the assigned value for the more critical quantities carried on analytes by implementing
the Joint committee for traceability in laboratory medicine reference methods. 相似文献
10.
Daniel W. Tholen 《Accreditation and quality assurance》2008,13(12):727-730
The revision of ISO/IEC Guide 43 is well underway by CASCO Working Group 28, with the author as Convener. The ballot on the
committee draft was successfully completed in June 2008. The Working Group met in September to resolve the CD comments and
to recommend that the document should advance as an ISO/IEC DIS. The document is in harmony with ISO/IEC 17025 (2005), ILAC G13 (2007), and the IUPAC Harmonized Protocol (2006) for proficiency testing. Major changes from Guide 43 include considerations for inspection bodies, requirements for metrological
traceability of assigned values for calibration schemes, limitations on subcontracting, requirements for reporting the uncertainty
of assigned values, and for including method information and technical commentary in scheme reports. Minor changes include
requirements for equipment used in the manufacture and testing of proficiency test items, considerations for handling laboratories’
reported uncertainties, and the issuance of certificates of participation. These changes have not generated any substantial
objections from the CASCO membership and liaisons. 相似文献
11.
Michael Thompson 《Accreditation and quality assurance》2006,10(9):501-505
The interpretation of the results of proficiency tests by the use of mixture models is described. The data are interpreted as a sample from a mixture of several normal populations. The calculation of the statistics (the means, variances and proportions of each component) is accomplished by means of the ‘EM’ algorithm. The method has several advantages over those previously advanced, principally that the algorithm is fast and easy to execute. Examples from proficiency testing are discussed. 相似文献
12.
Shakhashiro A Gondin da Fonseca Azeredo AM Sansone U Fajgelj A 《Analytical and bioanalytical chemistry》2007,387(7):2509-2515
The IAEA Reference Materials Group of the Chemistry Unit, Agency’s Laboratories Seibersdorf, has developed and optimized a
procedure for spiking some environmental matrices with gamma-emitting radionuclides. This paper describes the spiking procedure,
homogeneity testing of the spiked material, and assignment of property values and their associated uncertainties for the radionuclides
54Mn, 65Zn, 60Co, 109Cd, 134Cs, 137Cs, 210Pb, and 241Am. This procedure has already been successfully used in an IAEA proficiency test on the determination of 137Cs and 210Pb in spiked soil and has been found to be appropriate for production of soil materials for proficiency testing and internal
quality control samples. The main advantage of this procedure is a low uncertainty arising from heterogeneity, which was found
to be less than 1.2% for all the analytes studied.
相似文献
13.
In the evaluation of measurement uncertainty, the uncertainty budget is usually used to identify dominant terms that contribute
to the uncertainty of the output estimate. Although a feature of the GUF method, it is also recommended as a qualitative tool
in MCM by using ‘nonlinear’ equivalents of uncertainty contributions and sensitivity coefficients. In this paper, the use
of ‘linear’ and ‘nonlinear’ parameters is discussed. It is shown that when and only when the standard uncertainty of the output
estimate is nearly equal to the square root of the sum of the squares of the individual uncertainty contributions, will the
latter be a reliable tool to detect the degree of contribution of each input quantity to the measurand uncertainty. 相似文献
14.
In both European legislation relating to the testing of food and the recommendations of the Codex Alimentarius Commission, there is a movement away from specifying particular analytical methods towards specifying performance criteria to which any methods used must adhere. This ‘criteria approach’ has hitherto been based on the features traditionally used to describe analytical performance. This paper proposes replacing the traditional features, namely accuracy, applicability, detection limit and limit of determination, linearity, precision, recovery, selectivity and sensitivity, with a single specification, the uncertainty function, which tells us how the uncertainty varies with concentration. The uncertainty function can be used in two ways, either as a ‘fitness function’, which describes the uncertainty that is fit for purpose, or as a ‘characteristic function’ that describes the performance of a defined method applied to a defined range of test materials. Analytical chemists reporting the outcome of method validations are encouraged to do so in future in terms of the uncertainty function. When no uncertainty function is available, existing traditional information can be used to define one that is suitable for ‘off-the-shelf’ method selection. Some illustrative examples of the use of these functions in methods selection are appended. 相似文献
15.
Wilfried Hinrichs 《Accreditation and quality assurance》2012,17(2):167-175
A major factor for the durability of concrete is the protection against corrosion of reinforcing steel. One out of some corrosion
agents are dissolved chlorides. Therefore, their contents are limited in the raw materials and subject to a compliance assessment.
The concrete standard EN 206-1 provides both a semi-probabilistic calculation method for the design of concrete as regards
the input of chlorides through the components and a decision rule for compliance assessment. This paper describes a full probabilistic
approach to the compliance assessment taking into account the heterogeneity of the components and the uncertainty of testing.
The content of Cl− is defined as the sum of gamma-distributed parameters. The uncertainty data are taken from the test procedures and from effects
due to sampling procedures. The proposed approach is quantified for a high-performance and for a simple concrete. It allows
calculating upper limits of chloride contents according to the client’s requirements for conformity and/or for producer’s/consumer’s
risks. Additionally discussed are the particular financial consequences of incorrect decisions. Major results of the application
of the probabilistic approach are that the upper limits of the chloride contents are comparable to those of the semi-probabilistic
one and that the risks for high-performance concretes are not negligible. The decision rule given in EN 206-1 is easy to apply
but not unambiguous. The probabilistic approach permits to define concepts for decision rules based on the probability of
conformity or on the appropriate risks. For risk-based concepts, the individual performance of the testing laboratory can
be taken into account. 相似文献
16.
P. Medina-Pastor M. Mezcua C. Rodríguez-Torreblanca A. R. Fernández-Alba 《Analytical and bioanalytical chemistry》2010,397(7):3061-3070
The obligation for accredited laboratories to participate in proficiency tests under ISO 17025, performing multiresidue methods
(MRMs) for pesticide residues, involves the reporting of a large number of individual z scores making the evaluation of the overall performance of the laboratories difficult. It entails, time and again, the need
for ways to summarise the laboratory’s overall assessment into a unique combined index. In addition, the need for ways to
continually evaluate the performance of the laboratory over the years is equally acknowledged. For these reasons, following
14 years of the European Union Reference Laboratory for Pesticide Residues in Fruits and Vegetables (EUPT-FV), useful formulas
have been designed to globally evaluate the assessment of the participating laboratories. The aim is to achieve a formula
which is easy to understand, which can be applied and which fits the purposes of long-term evaluation detecting positive and
negative trends. Moreover, consideration is needed for a fair compensation of bad results in MRM, taking into account the
large number of compounds that are covered. It is therefore important to be aware of the difficulties in getting satisfactory
values from a wide range of compounds. This work presents an evaluation of the main well-established combined z score formulas together with those new ones developed here which have been applied to the European proficiency test results
(EUPTs) over the years. Previous formulas such as the rescaled sum of z score (RSZ), the sum squared of z score (SSZ) and the relative laboratory performance (RLP) are compared with the newer ones: the sum of weighted z scores (SWZ) and the sum of squared z scores (SZ2). By means of formula comparisons, conclusions on the advantages, drawbacks and the most fit-for-purpose approach
are achieved. 相似文献
17.
Kaj Heydorn 《Accreditation and quality assurance》2006,10(9):479-484
Proficiency data with stated uncertainties represent a unique opportunity for testing that the reported uncertainties are consistent with the Guide to the expression of uncertainty in measurement (GUM). In most proficiency tests, however, this opportunity is forfeited, because proficiency data are processed without regard to their uncertainties. In this paper we present alternative approaches for determining a reference value as the weighted mean of all mutually consistent results and their stated uncertainties. Using an accepted reference value each reported uncertainty estimate can be expressed as an E
n
number, but a value of confirms its validity only if the uncertainty of the reference value is negligible in comparison.Reference values calculated for results from an International Measurement Evaluation Programme (IMEP-9) by “bottom up” as well as “top down” methods were practically identical, although the first strategy yielded the lowest uncertainty. A plot of individual coefficients of variation (CV) versus E
n
numbers helps interpretation of the proficiency data, which could be used to validate relative uncertainties down to <1%. 相似文献
18.
A. Caurant B. Lalère M-C. Schbath C. Stumpf C. Sutour T. Mace J-P. Quisefit J-F. Doussin S. Vaslin-Reimann 《Analytical and bioanalytical chemistry》2010,398(5):2265-2277
A certified matrix reference material (CRM) for the measurement of benzene in ambient air has been developed at Laboratoire
National de Métrologie et d’Essais. The production of these CRMs was conducted using a gravimetric method fully traceable
to the International System of Units. The CRMs were prepared by sampling an accurate mass of a gaseous primary reference material
of benzene, using a high-precision laminar flowmeter and a mass flow controller, with a PerkinElmer sampler filled with Carbopack™
X sorbent. The relative standard deviations obtained for the preparation of a batch of 20 tubes loaded with 500 ng of benzene
were below 0.2%. Each CRM is considered independent from the others and with its own certified value and an expanded uncertainty
estimated to be within 0.5%, lower than the uncertainties of benzene CRMs already available worldwide. The stability of these
materials was also established up to 12 months. These CRMs were implemented during proficiency testing, to evaluate the analytical
performances of seven French laboratories involved in benzene air monitoring. 相似文献
19.
J. Kučera P. Mader D. Miholová J. Száková I. Stejskalová V. Štěpánek 《Analytical and bioanalytical chemistry》1998,360(3-4):439-442
A set of test materials of the green alga Chlorella vulgaris with different levels of naturally bound Cd and about the same levels of other 13 essential or trace elements (BIOMA 1–4)
was produced for proficiency testing of laboratories involved in elemental analysis of food. Criteria of the laboratories’
performance, such as the z-score and combination scores RSZ and SSZ were evaluated and discussed in terms of their suitability
for proficiency testing using a set of test materials with the same matrix. The use of the test materials as a set of internal
reference materials has also been suggested.
Received: 23 May 1997 / Revised: 1 August 1997 / Accepted: 11 August 1997 相似文献
20.
Wilfried Hinrichs 《Accreditation and quality assurance》2010,15(5):289-296
The reliability of test results and subsequent classification statements or product certification depend on the variability
of the product’s properties and on the validity of the test procedures used. With an emphasis on measurement uncertainty,
producer’s and user’s risks as well as probabilities of conformance, conformity and classification are calculated exemplarily
for two requirements for mineral aggregates used in construction. An important methodological basis is an international draft
document on measurement uncertainty in conformity assessment. The mathematical instruments given are applied and further developed
to a risk scenario for product classification. The results from a classification point of view show that the reliability of
test results for acid-soluble sulphates is mostly acceptable and both the producer’s and user’s risks are quite small. In
contrast, the magnesium sulphate index test produces results which are hardly usable for classification and certification
purposes or for risk management in production. Product certification bodies should generally have an appropriate approach
when dealing with results where precision data are poor. 相似文献