首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
《Electroanalysis》2004,16(21):1777-1784
The surface of boron‐doped diamond (BDD) electrode is modified by the polymer film for the first time. The cationic polymer film of N,N‐dimethylaniline (DMA) is electrochemically deposited on BDD electrode surface. This polymer (PDMA) film‐coated BDD electrode is used as a sensor which selectively detect dopamine (DA) in the presence of ascorbic acid (AA). This electrode also can detect both DA and its metabolite, 3,4‐dihydroxy phenyl acetic acid (DOPAC) in the presence of AA in the range of the physiological concentrations of these species. Favorable ionic interaction (i.e., electrostatic attraction) between the PDMA film and AA or DOPAC lowers their oxidation potentials and enhances the current response for AA and DOPAC compared to that at the bare electrode. The PDMA film also shows a hydrophobic interaction with DA and DOPAC. In cyclic voltammetric measurements, the PDMA film‐coated electrode can successfully separate the oxidation potentials for AA and DA coexisting in the same solution and the separation is about 200 mV. AA oxidizes at more negative potential than DA. In square‐wave voltammetry, the sensitivity of the PDMA film‐coated BDD electrode for DA in the presence of higher concentration of AA is higher than that of the PDMA film‐coated glassy carbon electrode. The hydrodynamic amperometric experiments confirm that the oxidation of AA is not affected by the oxidized product of DA and vice versa. So, unlike the bare electrode the catalytic oxidation of AA by the oxidized DA is eliminated at the PDMA film‐coated BDD electrode. The sensitivities of the modified electrode for AA, DA and DOPAC, which are present in the same solution with their physiological concentration ratios, are calculated to be 0.070, 0.363 and 0.084 μA μM?1, respectively. The modified electrode exhibits a stable and sensitive response to DA.  相似文献   

2.
The present study reports the simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA) in 0.20 M phosphate buffer solution (pH 5.0) using electropolymerized ultrathin film of 5-amino-2-mercapto-1,3,4-thiadiazole (AMT) on glassy carbon (GC) electrode. The bare GC electrode does not separate the voltammetric signals of AA, DA and UA. However, electropolymerized AMT (p-AMT) modified GC electrode not only resolved the voltammetric signals of AA, DA and UA but also dramatically enhanced their oxidation peak currents when compared to bare GC electrode. The enhanced oxidation currents for AA, DA and UA at p-AMT modified electrode are due to the electrostatic interactions between them and the polymer film. Using amperometric method, we achieved the lowest detection of 75 nM AA, 40 nM DA and 60 nM UA at p-AMT modified electrode. The amperometric current was linearly increased from 200 nM to 0.80 mM for each AA, DA and UA and the lowest detection limit was found to be 0.92, 0.07 and 0.57 nM, respectively (S/N = 3). The practical application of the modified electrode was demonstrated by the determination of DA in dopamine hydrochloride injection.  相似文献   

3.
Gold electrodes modified with cationic self-assembled monolayers (SAMs) of 2,2'-dithiobisethaneamine (CYST) and 6,6'-dithiobishexaneamine (DTH) were used for the simultaneous determination of dopamine (DA) and ascorbate (AA). The cationic SAM modified electrodes have several advantages over the bare electrode for the oxidation of AA. A very large (approximately 450 mV) decrease in the overpotential for the oxidation of AA when compared with the bare electrode has been observed at the cationic monolayer-modified electrode. The electrostatic interaction of negatively charged AA with the monolayer shift the oxidation peak potential of AA to less positive potential and enhances the peak current. On the other hand, the positively charged DA is repelled from the monolayer and the oxidation potential shifts to more positive potential when compared to the bare electrode. The electrochemical oxidation of AA at the mixed monolayer of CYST and diethyl disulfide (DEDS) supports the influence of cationic terminal group of the monolayer on the oxidation of AA. Since the oxidation of AA occurs well before the oxidation potential of DA is reached, the homogeneous catalytic oxidation of AA by the oxidized DA has been advantageously eliminated at the monolayer-modified electrode. The cationic self-assembled monolayers successfully detect DA in the presence of high concentration of AA. The sensitivity of the electrode modified with CYST monolayer was found to be 0.036 and 0.021 microA/microM towards AA and DA, respectively.  相似文献   

4.
Kumar SA  Tang CF  Chen SM 《Talanta》2008,74(4):860-866
Here, we described a new method for electrochemically selective detection of dopamine (DA). In this report, for the first time, electrochemical polymerization of 4-amino-1-1'-azobenzene-3,4'-disulfonic acid (acid yellow 9 dye (AY)) was carried out onto the surface of glassy carbon (GC) electrode and indium tin oxide coated electrode (ITO) from acidic solution containing AY monomers. A polymerized film of acid yellow on the surface of a glassy carbon electrode was characterized by cyclic voltammetry (CV). The redox response of the poly(AY) film on the GC electrode showed a couple of redox peak in 0.1M sulfuric acid solution and the pH dependent peak potential was -58mV/pH which was close to the Nernst behavior. The poly(AY) film-coated GC electrode (GC/PAY) exhibited excellent electrocatalytic activity towards the oxidations of dopamine (DA) in 0.1M phosphate buffer solution (PBS, pH 7.0) and increased the anodic peak current three time higher than bare GC electrode. GC/PAY did not reduce the considerable overpotential for oxidation of DA when compare to bare GC electrode. However, in contrast to other polymer modified electrode, due to the strong negatively charged back bone of poly(AY) highly repelled the important interference of DA, such as ascorbic acid (AA), uric acid (UA) and reduced form of nicotinamide adenine dinucleotide (NADH) in 0.1M PBS (pH 7.0) and did not showed any response for oxidation of these interferences. This behavior makes the GC/PAY for selective detection of DA in the presence of higher concentrations AA, UA and NADH. Using differential pulse voltammetry the calibration curves for DA were obtained over the range of 1-100muM with good selectivity and sensitivity. The proposed method provides a simple method for selective detection of DA from its interferences.  相似文献   

5.
A platinum (Pt) electrode modified by single-walled carbon nanotubes (SWNTs) and phytic acid (PA) was investigated by voltammetric methods in buffer solution. The PA-SWNTs/Pt-modified electrode demonstrated substantial enhancements in electrochemical sensitivity and selectivity towards dopamine (DA) in the presence of L-ascorbic acid (AA) and uric acid (UA). The PA-SWNTs films promoted the electron transfer reaction of DA, while the PA film, acting as a negatively charged linker, combined with the positively charged DA to induced DA accumulation in the film at pH under 7.4. However, the PA film restrained the electrochemical response of the negatively charged AA due to the electrostatic repulsion. The anodic peak potentials of DA, AA and UA could be separated by electrochemical techniques, and the interferences from AA and UA were effectively eliminated in the DA determination. Linear calibration plots were obtained in the DA concentration range of 0.2-10 μM and the detection limit of the DA oxidation current was determined to be 0.08 μM at a signal-to-noise ratio of 3. The results indicated that the modified electrode can be used to determine DA without interference from AA and UA, while ensuring good sensitivity, selectivity, and reproducibility.  相似文献   

6.
《Electroanalysis》2004,16(4):289-297
The polymer film of N,N‐dimethylaniline (DMA) is deposited on the electrochemically pretreated glassy carbon (GC) electrode by continuous electrooxidation of the monomer. This poly N,N‐dimethylaniline (PDMA) film‐coated electrode can be used as an amperometric sensor of ascorbic acid (AA). The polymer film (thickness (?): 0.3±0.02 μm) having positive charge in its backbone attracts the anionic species AA. Thus, the anodic peak potential (350 mV vs. Ag|AgCl|NaCl(sat)) for the oxidation of AA at the bare electrode is largely shifted to the negative value (150 mV) at this electrode. The PDMA film‐coated electrode is stable in acidic, alkaline and neutral media and can sense AA at different pH's. The diffusion coefficients of AA in solution (D) and in film (Ds) were estimated by rotating disk electrode voltammetry: D=(5.5±0.1)×10?6 cm2 s?1 and Ds=(6.3±0.2)×10?8, (6.0±0.2)×10?8 and (4.7±0.2)×10?8 cm2 s?1 for 0.5, 1.5 and 3.0 mM AA, respectively. A permeability of AA through the PDMA film was found to decrease with increasing the concentration of AA in the solution. In the chronoamperometry, the current response for the oxidation of AA at different times elapsed after potential‐step application is linearly increased with the increase in AA concentration in a wide range of its concentration from 25 μM to 1.65 mM. In the hydrodynamic amperometry, a successive addition of 10 μM AA caused the successive increase in current response with equal amplitude and the sensitivity was calculated as 0.178 μA cm?2 μM?1. So, the fouling of the electrode surface caused by the oxidized product of AA is markedly eliminated at this PDMA film‐coated electrode. A flow injection analysis based on the present electrode was performed to estimate the concentration of vitamin C in fruit juice.  相似文献   

7.
Detection of dopamine (DA) in the presence of excess of ascorbic acid (AA) has been demonstrated using a conducting polymer matrix, poly (3,4-ethylenedioxythiophene) (PEDOT) film in neutral buffer (PBS 7.4) solution. The PEDOT film was deposited on a glassy carbon electrode by electropolymerization of EDOT from acetonitrile solution. Atomic force microscopy studies revealed that the electrodeposited film was found to be approximately 100 nm thick with a roughness factor of 2.6 nm. Voltammetric studies have shown catalytic oxidation of DA and AA on PEDOT modified electrode and can afford a peak potential separation of ∼0.2 V. It is speculated that the cationic PEDOT film interacts with the negatively charged ascorbate anion through favorable electrostatic interaction, which results in pre-concentration at a less anodic value. The positively charged DA tends to interact with the hydrophobic regions of PEDOT film through hydrophobic–hydrophobic interaction thus resulting in favorable adsorption on the polymer matrix. Further enhancement in sensitivity to micro molar level oxidation current for DA/AA oxidation was achieved by square wave voltammetry (SWV) which can detect DA at its low concentration of 1 μM in the presence of 1000 times higher concentration of AA (1 mM). Thus the PEDOT modified electrode exhibited a stable and sensitive response to DA in the presence of AA interference.  相似文献   

8.
A simple and reliable method for simultaneous electrochemical determination of ascorbic acid (AA) and dopamine (DA) is presented in this work. It was based on the use of the cationic surfactant cetylpyridinium chloride (CPC) that enables the separation of the oxidation peaks potential of AA and DA. Cyclic voltammetry (CV) as well as pulse differential voltammetry (PDV) were used in order to verify the voltammetric behaviour in micellar media. In the cationic surfactant CPC, a remarkable electrostatic interaction is established with negatively charged AA, as a consequence, the oxidation peak potential shifted toward less positive potential and the peak current increased. On the other hand, the positively charged DA is repelled from the electrode surface and the oxidation peak potential shifts toward more positive potential in comparison to the bare electrode. Therefore, the common overlapped oxidation peaks of AA and DA can be circumventing by using CPC. Parameter that affects the Epa and Ipa such as CPC concentration and pH were studied. Under optimised conditions, the method presented a linear response to AA and DA in the concentration range from 5 to 75 μmol L−1 and 10 to 100 μmol L−1, respectively. The proposed method was successfully applied to the simultaneous determination of AA and DA in dopamine hydrochloride injection (DHI) samples spiked with AA.  相似文献   

9.
采用多壁碳纳米管(MWNT)改性聚N,N-二甲基苯胺(PDMA)膜,制备了新型复合膜修饰玻碳电极,并用SEM、电化学方法对修饰电极进行表征。 结果表明,无论MWNT是以掺杂还是先滴涂MWNT再聚合DMA多层修饰方式,均会改变PDMA膜的形貌和电化学性能。 复合膜修饰电极比单一PDMA膜修饰电极大幅度提高了比表面积和电活化面积,同时使PDMA和MWNT更好地协同发挥其优良的电化学特性。 实验结果表明,层层修饰制备的聚N,N-二甲基苯胺/多壁碳纳米管复合膜修饰电极对香草醛的电化学响应远大于基体电极和其它方法制备的修饰电极,电催化作用显著提高,其过电位降低了148 mV,氧化峰电流约增加了6倍;其电极反应是吸附控制的不可逆氧化过程,转移电子数n为2,质子数m为1,传递系数α为0.4062,吸附量为Γ=3.527×10-9 mol/cm2;检出下限为8.0×10-7 mol/L,样品平均回收率为99.87%。  相似文献   

10.
A glassy carbon electrode (GCE) modified with docosyltrimethylammonium chloride (DCTMACl) is used for simultaneous determination of dopamine (DA) and ascorbic acid (AA) using differential pulse voltammetry (DPV) technique in 0.10 mol·L?1 phosphate buffer solution of pH 5.0. The cationic surfactant DCTMACl modified film has a positive charge. DA exists as the positively charged species, whereas AA is the negatively charged one in the solution. Thus, at DCTMACl film-modified GCE, the oxidation peak potential of AA shifts toward less negative potential and the peak current of AA increases a little, while the oxidation peak potential of DA shifts toward more positive potential and peak current decreases greatly in comparison with that on bare electrode. The two anodic peaks are separated around 200 mV. Under optimal conditions, the catalytic peak currents obtained from DPV increase linearly with concentrations of DA and AA in the ranges of 1.0?×?10?5 to 1.0?×?10?3?mol·L?1. This electrode has good reproducibility, high stability in its voltammetric response, and low detection limit (micromolar) for both AA and DA. The modified electrode has been applied to the determination of DA and AA in injection.  相似文献   

11.
IntroductionDAisoneofessentialparticipantsintheneuro transmissionprocessinmammaliancentralnervoussys tem .AlossofDA containingneuronsmayresultinsomeseriousdiseasesuchasParkinsonism .1Sinceitsdiscov eryinthe 195 0s ,DAhasbeenofinteresttoneuroscien tistsandchem…  相似文献   

12.
将以铂微粒修饰玻碳电极(GC)为基体的聚2,5-二甲氧基苯胺膜(PDMA)形成修饰电极(Pt/PDMA/GC).循环伏安实验表明,Pt/PDMA/GC电极对甲醇氧化比分散于玻碳电极上的铂催化活性更大。讨论了PDMA膜厚度、铂微粒含量及甲醇浓度对催化活性的影响。这种电极在酸性甲醇溶液中具有良好的稳定性。  相似文献   

13.
Chromium(VI) is determined through its direct electrochemical reduction in the bulk of a porous glassy carbon electrode. An electrode filled with the acidified sample and Cr(VI) is reduced by means of a constant current whereas the potential of the electrode is monitored. The limits of detection and quantification were found to be 1.9 and 6.0 μg · L−1, resp. The linear range, repeatability and reproducibility were found to be 5–500 μg · L−1, 1.2, and 1.8%, resp. The influence of Fe(III), Ca(II), Mg(II), sulphates, nitrates, humic acids and surfactants was investigated. Total chromium was measured after chemical oxidation of Cr(III) to chromate by permanganate. The method was applied to analyses of water samples.  相似文献   

14.
Electrochemical synthesis of ruthenium oxide (RuOx) onto Nafion-coated glassy carbon (GC) electrode and naked GC electrode were carried out by using cyclic voltammetry. Electrochemical deposition of RuOx onto Nafion-coated electrode was monitored by in situ electrochemical quartz crystal microbalance (EQCM). Surface characterizations were performed by scanning electron microscope (SEM) and atomic force microscope (AFM). SEM and AFM images revealed that ruthenium oxide particles incorporated onto the Nafion polymer film. In addition, a GC electrode modified with ruthenium oxide–Nafion film (RuOx–Nf–GC) was shown excellent electrocatalytic activity towards dopamine (DA) and ascorbic acid (AA). The anodic peak current increases linearly over the concentration range of 50 μM–1.1 mM for DA with the correlation coefficient of 0.999, and the detection limit was found to be (S/N = 3) 5 μM. Owing to the catalytic effect of the modified film towards DA, the modified electrode resolved the overlapped voltammetric responses of AA and DA into two well-defined voltammetric peaks with peak-to-peak separation about 300 mV. Here, RuOx–Nf–GC electrode employed for determination of DA in the presence of AA. This modified electrode showed good stability and antifouling properties.  相似文献   

15.
Palraj Kalimuthu 《Talanta》2010,80(5):1686-319
This paper describes the simultaneous determination of ascorbic acid (AA), dopamine (DA), uric acid (UA) and xanthine (XN) using an ultrathin electropolymerized film of 2-amino-1,3,4-thiadiazole (p-ATD) modified glassy carbon (GC) electrode in 0.20 M phosphate buffer solution (pH 5.0). Bare GC electrode failed to resolve the voltammetric signals of AA, DA, UA and XN in a mixture. On the other hand, the p-ATD modified electrode separated the voltammetric signals of AA, DA, UA and XN with potential differences of 110, 152 and 392 mV between AA-DA, DA-UA and UA-XN, respectively and also enhanced their oxidation peak currents. The modified electrode could sense 5 μM DA and 10 μM each UA and XN even in the presence of 200 μM AA. The oxidation currents were increased from 30 to 300 μM for AA, 5 to 50 μM for DA and 10 to 100 μM for each UA and XN, and the lowest detection limit was found to be 2.01, 0.33, 0.19 and 0.59 μM for AA, DA, UA and XN, respectively (S/N = 3). The practical application of the present modified electrode was demonstrated by the determination of AA, UA and XN in human urine samples.  相似文献   

16.
The electrosynthesis of polypyrrole (PPy) film has been achieved on glassy carbon electrode (GCE) in aqueous medium of Congo red (CR) by means of cyclic voltammetry (CV). The modified electrode exhibits high electrocatalytic activity toward dopamine (DA) oxidation, with drastic enhancement of the reversibility and peak currents. This modified electrode, due to electrostatic interactions, is capable to mask the response of ascorbic acid (AA) completely and provide an effective method for the detection of minor amounts of dopamine in the presence of high concentrations of AA. The electrochemical response of the film modified electrode is strongly dependent to the switching potential applied in the CV procedure of the electro‐polymerization. The results show that by increasing the switching potential more than 0.75 V, the peak of AA is gradually disappeared. This peak in potential of 0.85 V is reached to capacitive background current. With respect to the destruction of the conjugated structure of ppy and lowering the conductivity of the film at the surface of modified electrode, higher switching potentials cannot be suitable for electropolymerization procedure. The effects of various experimental parameters such as, number of polymerization cycles, switching potential, pH and potential sweep rate on the voltammetric response of dopamine were also investigated. The modified electrode shows a linear response to DA in the range of 0.5 to 100 μM with a detection limit of 0.1 μM. The prepared modified electrode does not show any considerable response toward sulfhydryl compounds, such as, cysteine, penicillamine and glutathione, revealing a good selectivity for voltammetric response to DA. The effective electrocatalytic property, ability for masking the voltammetric responses of the other biological reducing agents together with high reproducibility and stability make the modified electrode suitable for selective and sensitive voltammetric detection of sub‐micromolar amounts of DA in clinical and pharmaceutical preparations.  相似文献   

17.
Zhang Y  Su S  Pan Y  Zhang L  Cai Y 《Annali di chimica》2007,97(8):665-674
Trans-3-(3-pyridyl) acrylic acid (PAA) was deposited on glassy carbon electrode (GCE) by electropolymerization in pH 7.0 phosphate buffer solution (PBS). The poly (3-(3-pyridyl) acrylic acid) (PPAA) film modified glassy carbon electrode shows an excellent electrochemical response for dopamine (DA), ascorbic acid (AA) and uric acid (UA). The cyclic voltammetry oxidation peaks for DA and AA, DA and UA, AA and UA are separated by 150 mV, 130 mV and 280 mV, respectively. This permits the simultaneous determination of AA, DA and UA. The interference of AA with the determination of DA could be eliminated because of the electrostatic interaction between DA cations and the negatively charged PPAA film at pH 7.0. The anodic peak currents of DA, AA and UA increase linearly with concentration in the range of 1-40 micromol L(-1), 10-400 micromol L(-1) and 1.6-80 micromol L(-1), respectively, with a correlation coefficient (r) always higher than 0.998. The detection limit is 0.06 micromol L(-1), 0.8 micromol L(-1) and 1.1 micromol L(-1) for DA, AA and UA, respectively.  相似文献   

18.
The electrochemical oxidation of ascorbic acid (AA) and serotonin (5-HT) at a boron-doped diamond (BDD) electrode modified with poly(N,N-dimethylaniline) (PDMA) has been studied. The oxidation potentials of 5-HT and AA overlapped after mixing of the two chemicals, due to interference of AA at the bare BDD electrode. However, after modifying the BDD electrode with a cationic polymer (PDMA), the oxidation peaks of 5-HT and AA were separated. PDMA-coated BDD electrodes can be used for simultaneous detection of these species.  相似文献   

19.
通过电化学聚合法在碳糊电极上共聚制备了聚邻氨基酚/Ni2+膜(Ni2+/P-OAP/CPE), 研究了膜的伏安特性, 并制成dsDNA修饰电极, 通过电化学和紫外光谱法进行表征. 将dsDNA/Ni2+/P-OAP/CPE电极应用于多巴胺的电催化氧化, 同时将该方法用于盐酸多巴胺针剂的测定, 亦获得了满意的结果.  相似文献   

20.
Ascorbic acid (AA) is a vital component in the diet of humans and is known to take part in several biological reactions. The investigation and determination of AA has therefore always been of interest for chemists. There is a higher overpotential for the bare electrode, because the product of AA oxidized is a surface fouling to the electrode. There are some electrocatalytic oxidation and determination of AA at the chemically modified electrode (CME). In this paper,we describe the improved voltammetric behavior of AA and its determination at a polyalanine CME.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号