首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
A method utilizing differential pulse polarography for the determination of chromium(VI) in natural water is described. Additions of 0.62 μg Cu(II) ml-1 and 0.55 μg Fe(III) ml-1 did not interfere with the determination of 0.050 μg Cr(VI) ml-1. The natural water samples containing chromium(VI) were buffered to approximately pH 7 with 0.1 M ammonium acetate and 0.005 M ethylene diamine and analyzed. Natural water samples of chromium content from 0.035 μg ml-1 to 2.0 μg ml-1 may be analyzed directly without further preparation. The detection limit is 0.010 μg ml-1.  相似文献   

2.
This paper describes a micelle-mediated phase separation in the presence of electrolyte as a preconcentration method for cadmium determination by flame atomic absorption spectrometry (FAAS). Cadmium was complexed with ammonium O,O-diethyldithiophosphate (DDTP) in an acidic medium (0.32 mol l 1 HCl) using Triton X-114 as surfactant and quantitatively extracted into a small volume (about 20 μl) of the surfactant-rich phase after centrifugation. The chemical variables that affect the cloud point extraction, such as complexing time (0–20 min), Triton X114 concentration (0.043–0.87% w/v) and complexing agent concentration (0.01–0.1 mol l 1), were investigated. The cloud point is formed in the presence of NaCl at room temperature (25 °C), and the electrolyte concentration (0.5–5% w/v) was also investigated. Under optimized conditions, only 8 ml of sample was used in the presence of 0.043% w/v Triton X-114 and 1% (w/v) NaCl. This method permitted limits of detection and quantification of 0.9 μg l 1 and 2.9 μg l 1 Cd, respectively, and a linear calibration range from 3 to 400 μg l 1 Cd. The proposed method was applied to Cd determination in physiological solutions (containing 0.9% (w/v) of NaCl), mineral water, lake water and cigarette samples (tobacco).  相似文献   

3.
A flow injection (FI) spectrophotometric determination of europium (III) is described, based on the complexation between europium (III), and chlortetracycline (CTC) in a Tris-buffer pH 8.0 medium. The resulting yellow-coloured complex is measured at its absorption maximum of 400 nm after 100 μl of sample or standard solution containing europium (III) are injected into the merged streams of CTC and Tris-buffer solutions. Optimum conditions for determining μg amounts of europium (III) are achieved by univariate method. Various types of reactors are also investigated. It is shown that the use of a single bead string reactor gives rise to the enhancement of peak height. A linear calibration curve over the range of 0.10-0.60 μg ml−1 europium (III) is established with the regression equation (n=6) Y=34.93X+0.01 and the correlation coefficient of 0.9994 is obtained. A detection limit (3σ) of 0.01 μg ml−1 of europium (III) and the relative standard deviation (R.S.D.) of 4.32% for determining 1.0 μg ml−1 of europium (III) (n=7) are obtained. The recommended method has been applied to the quantitation of europium (III) in spiked water and stream sediment samples with average recoveries of 99.9 and 97.5%, respectively. The sampling rate is found to be 85 h−1.  相似文献   

4.
A novel solid phase extraction technique for determination of total iron in environmental water samples was developed. The method is based on sorption of Fe(III) ions on octadecyl silica membrane disk modified with a new synthetic ligand dimethyl(E)‐2‐(2‐methoxyphenoxy)‐2‐butenedioate (I). Iron(III) is quantitatively retained on the disk in the pH range of 3–7 at a flow rate of 1–7 mL min−1. The Fe(III) eluted with 10 mL of 0.01 M EDTA and than was measured by flame atomic absorption spectrometry (FAAS) at 248.3 nm. The maximum capacity disk modified by 7 mg of ligand was found to be 197 ± 2 μg of iron(III). The breakthrough volume was greater than 2000 mL. The iron(III) was completely recovered (> 99%) from water with a preconcentration factor of more than 200. The limit of detection of the proposed method was 1.00 ng mL−1. The various cationic and anionic interferences had no effect on the recovery of iron(III) from the binary mixtures. The proposed method was successfully applied to determination of total iron from three different water samples.  相似文献   

5.
A method for the determination of low levels of ammonium ion in solution by optical emission spectrometry with an inductively coupled argon plasma source operated at 27 MHz is presented. The ammonium ion is oxidized with sodium hypobromite in alkaline medium, the evolved nitrogen is passed into the argon plasma, and the NH emission intensity produced in the plasma at 336.0 nm is monitored. A practical detection limit of 0.1 μg N ml-1 for 5-ml aqueous sample solutions has been obtained. The method has been applied to the determination of the exchangeable ammonium content of soil samples.  相似文献   

6.
A reversed flow injection colorimetric procedure for determining iron(III) at the μg level was proposed. It is based on the reaction between iron(III) with norfloxacin (NRF) in 0.07 mol l−1 ammonium sulfate solution, resulting in an intense yellow complex with a suitable absorption at 435 nm. Optimum conditions for determining iron(III) were investigated by univariate method. The method involved injection of a 150 μl of 0.04% w/v colorimetric reagent solution into a merged streams of sample and/or standard solution containing iron(III) and 0.07 mol l−1 ammonium sulfate in sulfuric acid (pH 3.5) solution which was then passed through a single bead string reactor. Subsequently the absorbance as peak height was monitored at 435 nm. Beer's law obeyed over the range of 0.2–1.4 μg ml−1 iron(III). The method has been applied to the determination of total iron in water samples digested with HNO3–H2O2 (1:9 v/v). Detection limit (3σ) was 0.01 μg ml−1 the sample through of 86 h−1 and the coefficient of variation of 1.77% (n=12) for 1 μg ml−1 Fe(III) were achieved with the recovery of the spiked Fe(III) of 92.6–99.8%.  相似文献   

7.
A very sensitive and rapid potentiometric determination of trace chlorine in water is described. The method is based on the transient potential changes which appears during the reduction of dissolved chlorin with an iron(III)/iron(II) potential buffer containing chloride and sulfuric acid. The sample is injected into a water carrier stream and merged with a stream of this potential buffer solution; chlorine is reduced during passage through a short reaction coil. The potential change from the baseline is measured with a flow-through ORP (oxidation-reduction potential) electrode. Potential changes (peak heights) are proportional to chlorine concentrations from 10?7 M to 10?5 M. The detection limit is 5 × 10?8 M (3.5 μgl?1 as Cl2). The sample throughput is 45 h?1. Reproducibility is in the range 2.5–1.1%. Results for potable water agree with those obtained by the o-tolidine method.  相似文献   

8.
A highly sensitive method has been developed for the determination of titanium(IV) and iron(III) by ion-pair reversed phase liquid chromatography using sodium 1,2-dihydroxybenzene-3,5-disulfonic acid (Tiron) as a precolumn chelating reagent. The metal - Tiron chelates were separated on a C18 (ODS) column; the mobile phase was a 2:8 (v/v) mixture of acetonitrile and acetate buffer (0.04 mol/L, pH 6.2) containing 2.0 × 10?3 mol/L Tiron, 0.04 mol/L tetrabutylammonium bromide, and 0.1 mol/L potassium nitrate. The detection limits for titanium(IV) and iron(III) are 0.5 and 2.0 μg/L, respectively. The method has been applied to the simultaneous determination of titanium(IV) and iron(III) in river water samples and has furnished highly precise results.  相似文献   

9.
A highly simple and sensitive kinetic spectrofluorometric method was developed for the determination of thioctic acid. The method is based on the oxidation of the studied drug with cerium(IV) ammonium sulfate in acidic medium. The fluorescence of the produced Ce(III) was measured at 365 nm after excitation at 255 nm. The different experimental parameters affecting the development and stability of the reaction product were carefully studied and optimized. The method is applicable over the concentration range of 0.02 to 0.12 μg/mL with a detection limit of 6.06 × 10?3 μg/mL and a quantification limit of 0.02 μg/mL. The method was successfully applied for the assay of the studied drug in pharmaceutical formulations. The results obtained were in good agreement with those obtained with the reference method.  相似文献   

10.
《Analytical letters》2012,45(3):463-476
Abstract

A solvent-soluble membrane filter is proposed for a simple and rapid preconcentration and spectrophotometric determination of iron (II), which was collected on a nitrocellulose membrane filter as an ion-associate of the cationic complex of iron (II)-1,10-phenanthroline with an anionic surfactant of dodecyl sulfate. The ion-associate collected was dissolved in 5 ml of 2-methoxyethanol together with the filter. The color intensity due to the ion-associate in the resulting solution was measured at 510 nm against a reagent blank. Beer's law is obeyed in the range 1–15 μg Fe (II) in 5 ml of solvent with excellent reproducibility, and detection limits better than 0.5 μg dm?3 as Fe (II) can be achieved. The diverse components normally present in water do not interfere when proper masking reagent is added. The proposed method has been applied to the analysis of water samples from several sources such as river water, ground water and tapwater samples, the recoveries of the iron (II) added to the samples are quantitative, and results found are satisfactory.  相似文献   

11.
Magnetic solid phase extraction (MSPE) based on cetyltrimethylammonium bromide (CTAB)-coated magnetic iron oxide nanoparticles (C-MIONPs) was investigated for the separation, preconcentration and determination of Rose Bengal (RB) in aqueous solutions. The influences of different analytical parameters such as pH, temperature, ionic strength, volume of desorbent solvent, amount of adsorbent and interfering ions in the adsorption of RB on C-MIONPs were investigated. The RB adsorption on C-MIONPs follows Langmuir isotherm. The sizes of C-MIONPs were in the range of 20–80 nm. The method was capable of determining RB concentration in the range of 0.01–1.20 μg ml?1. The limit of detection (LOD) of RB based on three times the standard deviation of the blank (3Sb) was found to be 5.91 × 10–3 μg ml?1 (n = 8). The relative standard deviation (RSD) for 0.3 μg ml?1 and 0.8 μg ml?1 of RB were 4.1% and 1.1%, respectively. The proposed method was applied to the determination of RB in Brucella Antigen solution and water samples from the Karoon River.  相似文献   

12.
A very simple spectrophotometric method for simultaneous determination of aluminum(III) and iron(III) based on formation of their complexes with pyrocatechol violet (PCV) in micellar media, using the H‐point standard addition method (HPSAM), is described. In micellar media, the metal complexes of Al‐PCV and Fe‐PCV are formed very fast. Formation of both of the complexes was complete within 5 min at pH 8.5. The linear ranges for aluminum and iron were 0.05‐2.50 and 0.10‐4.00 μg mL?1, respectively. The relative standard deviation (R.S.D.) for the simultaneous determination 0.40 μg mL?1 of Al(III) and 0.20 μg mL?1 of Fe(III) were 3.24% and 4.22%, respectively. Interference effects of common anions and cations were studied. The method was applied to simultaneous determination of Al(III) and Fe(III) in standard reference material and alloy samples.  相似文献   

13.
In this research, we developed and validated a liquid chromatography coupled to mass spectrometry (LC–QToF–MS) method for simultaneous quantification of the anti-tuberculosis drugs ethambutol, isoniazid, pyrazinamide and rifampicin in human plasma. Plasma samples spiked with cimetidine (internal standard) were extracted using protein precipitation with acetonitrile containing 1% formic acid. Separation was performed using a C18 column under flow gradient conditions with water and acetonitrile, both containing 5 mm ammonium formate and 0.1% formic acid. The method was validated according to the ANVISA and US Food and Drug Administration guidelines for bioanalytical method validation. The calibration curve was linear over a concentration range of 0.2–5 μg ml−1 for ethambutol, 0.2–7.5 μg ml−1 for isoniazid, 1–40 μg ml−1 for pyrazinamide and 0.25–2 μg ml−1 for rifampicin, all with adequate precision and accuracy. The method was reproducible, selective and free of carryover and matrix effects. The validated LC–QToF–MS method was successfully applied to real samples and shown to be applicable to future therapeutic and pharmacokinetic monitoring studies.  相似文献   

14.
A method of preparation of 10?2 ?10?3M standard solutions of the fluoride complex of manganese(III) by the reaction of manganese(II) with permanganate in a medium of potassium fluoride acidified with sulfuric acid has been developed. It has been found that in a medium of 1 M sulfuric acid, 0.5 M manganese(II) sulfate, and 0.1 M potassium fluoride these solutions are sufficiently stable for both direct and indirect titrimetric determinations. The titer was determined using potassium iodide as a primary standard and potentiometric, bipotentiometric, or biamperometric titration.  相似文献   

15.
《Analytical letters》2012,45(2):481-492
Abstract

A voltammetric method for the determination of iron at detection limit of 4 μg/l is described, using the catalytic current of the reduction of the Fe(III)-triethanolamine (TEA) complex in the presence of bromate ions. the determination was performed at a mercury hanging drop electrode without preconcentration, using the TEA alkaline solution as a supporting electrolyte and the differential pulse technique. A peak current for the Fe(III)-TEA catalytic reduction was observed at a potential of-1.0 V (Ag/AgCl saturated electrode). the influence of TEA, BrO3 and NaOH concentrations on the peak height was studied. It was found that a 100-fold excess of Mn, a 50-fold excess of Cr(VI) and Zn did not interfere in the determination. This method was applied to the determination of iron in water, snow and waste water samples.  相似文献   

16.
The process of precipitation of ammonium ferric sulfate dodecahydrate (NH4Fe(SO4)2·12H2O) from waste solutions, obtained during autoclave oxidation of pyrite concentrate has been studied. A special feature of these solutions is the high concentration of Fe(III) ions (>60 g L–1) and sulfuric acid (> 61 g L–1). Based on comprehensive laboratory tests, the study determined the optimal conditions for the precipitation process of ammonium ferric sulfate dodecahydrate (AFS) by salting out with ammonium sulfate: reagent excess (100% over stoichiometric, temperature 276 K, time 1 h). The process should be conducted under continuous slow stirring which would not allow forming of large crystals that are difficult to remove from the reactor. The test work confirmed that high quality crystals can be produced by prior oxidation of Fe(II) to Fe(III) ions using hydrogen peroxide and copper removal from the solution.  相似文献   

17.
This work presents a new ultra‐sensitive method of Al(III) as Al‐cupferron complex voltammetric determination, in 0.04 M ammonium sulfate of pH=6.1 and 0.003 M cupferron by environmentally friendly and durable Bismuth Bulk Annular Band Electrode (BiABE). The optimal measuring parameters include: potential window from ?700 to ?1250 mV versus Ag|AgCl, preconcentration time and potential of 120 s, ?700 mV, respectively. The electrode surface can be activated by fast in situ method: applying short conditioning by the potential of ?1300 mV. The best obtained analytical parameters are: range of linearity 0.2–1.2 μg L?1 with high sensitivity of 1.333 μA/μg L?1, limit of detection 0.04 μg L?1 and repeatability below 2.3 %. The described procedure was verified using various CRMs, i. e. surface waters, waste waters and tea leaves. Satisfactory recovery values were obtained in the interval 99.2–103.5 %. Developed DPV procedure was used to determine Al in tap and natural waters in aspect of recovery of aluminum, which was added to the samples. For the first time, we tested also Al removal efficiency from water by the water filters mounted in the trip bottle.  相似文献   

18.
A microemulsion containing sodium dodecyl sulphate and n-pentanol in a mass ratio of 1 : 4, water and a vegetable oil was investigated using pseudo-tenary phase diagrams. The medium can co-solve important amounts of vegetable oils and aqueous solutions over a wide range of ionic strengths. A procedure for the determination of 1.4–140 μg ml?1 of aniline in vegetable oils using ionic diazotization and coupling reactions was developed. The absorbance was measured in an optically clear microemulsion containing 4% or 20% of oil. The procedure is much simpler and rapid than the official chromatographic methods and gives almost the same limits of detection (ca. 05 μg ml?1) using no more than 1 ml of sample. The repeatability for 30 μg ml?1 aniline was 2%. Acid-base titrations in the microemulsion medium permitted the evaluation of the protonation constant of the dye.  相似文献   

19.
A coulometric method was developed for the determination of microamounts of sulphur in iron and steel. Hydrogen sulphide is quantitatively evolved by reduction with iron(II) in strong phosphoric acid medium and is titrated with electrolytically generated silver ion from a silver anode. Microamounts of sulphide (2.96–224.3 μg) in sodium sulphide standard solutions could be determined with an error of only a few percent. Sulphur in a potassium sulphate standard solution is quantitatively reduced to hydrogen sulphide and could be separated from the solution by heating and determined accurately. Trace amounts of sulphur (7–100 μg g?1) in iron and steels could be determined with a standard deviation of 0.7–2.1 μg g?1.  相似文献   

20.
《Electroanalysis》2017,29(4):1069-1080
In this study, we introduce a very sensitive and selective method for the differential pulse anodic stripping determination of Sb(III) ion on the over‐oxidized poly(phenol red) modified glassy carbon electrode (PPhRedox/GCE) in 0.1 mol L‐1 HCl medium. The formation of both poly(phenol red) and over‐oxidized poly(phenol red) film on the electrode surfaces were characterized by electrochemical impedance spectroscopy, X‐ray photoelectron spectroscopy and scanning electron microscopy techniques. An anodic stripping peak of Sb(III) was observed at 0.015 V on the PPhRedox/GCE. Higher anodic stripping peak current of Sb(III) was obtained at PPhRedox/GCE compared with both bare GCE and poly(phenol red) film modified GCE (PPhRed/GCE). The calibration graph consisted of two linear segments of 0.044 ‐ 1.218 μg L−1 and 3.40 – 18.26 μg L−1 with a detection limit of 0.0075 μg L−1. The proposed over‐oxidized polymer film modified electrode was applied successfully for the analysis of antimony in different spiked water samples. Spiked recoveries for water samples were obtained in the range of 93.0–103.0%. The accuracy of the method was also verified through the analysis of standard reference materials (SCP SCIENCE‐EnviroMAT™ EP−L‐2).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号