首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Fundamental understanding of the impact of reservoir potentials on the analyte behavior on the microfluidic chips is an important issue in microchip electrophoresis (MCE) for suitable injection and separation of analytes, since the applied potentials may significantly affect the shape of sample plug, sample leakage from the injection channel to the separation channel, injected sample amount, and separation efficiency. This study addressed this issue for the case of a conventional cross-geometry microchip with four reservoirs using computer simulations, the results of which were verified by the analysis of DNA fragments. For the microchip with a definite structure and migration distance, the injected sample amount was shown to be the vital parameter for improving the limit of detection and resolution. During injection, the shape of the sample plug could be adjusted by varying the reservoir potentials. It was demonstrated that a "magnified injection" (applying high voltage on the three reservoirs to the sample reservoir) is useful to enhance the detection sensitivity depending on the analyte composition, although such injection was previously avoided because of introducing too large amounts of the analyte in comparison with two established modes, floating and pinched injection. Optimal magnified injection was proved to improve the sensitivity for about 4 times over that of pinched injection for the analysis of DNA step ladders using microchip gel electrophoresis (MCGE). Sample leakage of DNA fragments could be suppressed by applying a high positive voltage on injection channel during separation, but the voltage degraded the injected amount and resolution.  相似文献   

2.
Hirokawa T  Takayama Y  Arai A  Xu Z 《Electrophoresis》2008,29(9):1829-1835
Aiming to achieve high-performance analysis of DNA fragments using microchip electrophoresis, we developed a novel sample injection method, which was given the name of floating electrokinetic supercharging (FEKS). In the method, electrokinetic injection (EKI) and ITP preconcentration of samples was performed in a separation channel, connecting two reservoir ports (P3 and P4) on a cross-geometry microchip. At these two stages, side channels, crossing the separation channel, and their ports (P1 and P2) were electrically floated. After the ITP-stacked zones passed the cross-part, they were eluted for detection by using leading ions from P1 and P2 that enabled electrophoresis mode changing rapidly from ITP to zone electrophoresis (ZE). Possible sample leakage at the cross-part toward P1 and P2 was studied in detail on the basis of computer simulation using a CFD-ACE+ software and real experiments, through which it was validated that the analyte recovery to the separation channel was almost complete. The FEKS method successfully contributed to higher resolution and shorter analysis time of DNA fragments on the cross-microchip owing to more rapid switching from ITP status to ZE separation in comparison with our previous EKS procedure realized on a single-channel microchip. Without any degradation of resolution, the achieved LODs were on average ten times better than using conventional pinched injection.  相似文献   

3.
We present a novel isotachophoresis–gel electrophoresis (ITP–GE) microchip system designed for rapid and efficient isotachophoretic preconcentration coupled with gel electrophoresis separation by using a negative pressure sampling technique. The overall ITP–GE procedure involves only three steps: sample loading, ITP preconcentration and GE separation and was controlled by a simple and compact negative pressure sampling device, which is composed of a vacuum vessel, a three-way electromagnetic valve and a single high voltage power supply. During the sample loading stage, a negative pressure was applied via a three-way electromagnetic valve in headspace of the two sealed sample waste reservoirs (SWs). A sandwiched sample zone between a leading and a terminating electrolyte zone was formed in the channel intersection in less than 1 s. Once the three-way electromagnetic valve was switched to connect SWs to ambient atmosphere to release vacuum in SWs, ITP preconcentration in free solution and GE separation in the 4% hydroxyethylcellulose (HEC) sieving material were consequently activated under the electric potentials applied. The performance of present approach was evaluated by using DNA fragments as model analytes. Compared to conventional cross microchip GE using electrokinetic pinched injection, an average signal enhancement of 185-fold was obtained with satisfactory resolution. The results demonstrated the ITP–GE approach possessing an exciting potential of high sensitivity and short sampling time with significant simplification in operation and instrumentation.  相似文献   

4.
基于微芯片电泳的脱氧核糖核酸片段的浓缩和分离   总被引:1,自引:0,他引:1  
徐中其  廣川健 《色谱》2009,27(1):102-106
采用超负荷电动供给(electrokinetic supercharging, EKS)预浓缩技术,在微芯片电泳(MCE)上对脱氧核糖核酸(DNA)片段进行浓缩和分离。EKS是集合样品电动进样(EKI)和过渡等速电泳(tITP)的一种在线浓缩方法。研究表明:采用该方法后,在40.5 mm长的单通道芯片上能够实现对低浓度样品的大量进样、浓缩和基线分离。在普通的紫外检测条件(检测波长为260 nm)下,对DNA片段的平均检出限(S/N=3)约为0.07 mg/L,仅为十字芯片上的微芯片电泳检出限的1/40。本文还对浓缩过程中的一些关键因素和定性分析进行了探讨。  相似文献   

5.
Xu Z  Nishine T  Arai A  Hirokawa T 《Electrophoresis》2004,25(21-22):3875-3881
Chip gel electrophoresis was explored for high-sensitivity detection of DNA by combining electrokinetic injection with transient isotachophoresis preconcentration (here named electrokinetic supercharging (EKS)). Low concentrations (0.2 mg/L) of DNA sample could be detected without fluorescence labeling using a conventional UV detector (at 260 nm). On a single-channel microchip, identification of PCR product was performed by exploiting both external and internal calibration methods. The deviation between the two calibration methods was about 3.6%, and the identified DNA fragment size matched with the predicted size of the template DNA. On the cross microchip the EKS preconcentration has also been achieved when changing the injection reservoir differing from the one used previously. The procedure was computer-simulated and the influence of the voltage applied to two-side reservoirs on sample preconcentration and dilution was also discussed.  相似文献   

6.
The research adopted a single-channel microchip as the probe, and focused electrokinetic injection combined with transient isotachophoresis preconcentration technique on capillary electrophoresis microchip to improve the analytical sensitivity of DNA fragments. The channel length, channel width and channel depth of the used microchip were 40.5 mm, and 110 and 50 μm, respectively. The separation was detected by CCD (charge-coupled device) (effective LENGTH=25 mm, 260 nm). A 1/100 diluted sample (0.2 mg/l of each DNA fragment) of commercially available stepladder DNA sample could be baseline separated in 120 s with S/N=2–5. Compared with conventional chip gel electrophoresis, the proposed method is ideally suited to improve the sensitivity of DNA analysis by chip electrophoresis.  相似文献   

7.
Study of injection bias in a simple hydrodynamic injection in microchip CE   总被引:1,自引:0,他引:1  
The electrokinetically pinched method is the most commonly used mode for sample injection in microchip capillary electrophoresis (microCE) due to its simplicity and well-defined sample volume. However, the limited injection volume and the electrophoretic bias of the pinched injection may limit its universal usage to specific applications. Several hydrodynamic injection methods in microCE have been reported; however, almost all claimed that their methods are bias-free without considering the dispensing bias. To investigate the dispensing bias, a simple hydrodynamic injection was developed in single-T and double-T glass microchips. The sample flow was produced by hydrostatic pressure generated by the liquid level difference between the sample reservoir and the other reservoirs. The reproducibility of peak area and peak area ratio was improved to a significant extent using large-surface reservoirs for the buffer reservoir and the sample waste reservoir to reduce the Laplace pressure effect. Without a voltage applied on the sample solution, the voltage-related sample bias was eliminated. The dispensing bias was analyzed theoretically and studied experimentally. It was demonstrated that the dispensing bias existed and could be reduced significantly by appropriately setting up the voltage configuration and by controlling the appropriate liquid level difference.  相似文献   

8.
Jang YC  Jha SK  Chand R  Islam K  Kim YS 《Electrophoresis》2011,32(8):913-919
Detection and quantitation of nucleic acids have gained much importance in the last couple of decades, especially in the post-human genome project era. Such processes are tedious, time consuming and require expensive reagents and equipment. Therefore, in the present study, we demonstrated a simple process for the separation and analysis of small DNA fragments using capillary electrophoretic amperometric detection on an inexpensive disposable glass microchip. The device used polydimethylsiloxane engraved microchannel and Au/Ti in-channel microelectrodes for sample detection. The DNA fragments were separated under low electric field (20 V/cm) for improved detection sensitivity and to retain the biomolecules in their native conformation. With a low sample requirement (as low as 1 μL) and high reproducibility, the proposed microchip device was successful in resolution and detection of DNA fragments of various lengths.  相似文献   

9.
Tabuchi M  Baba Y 《Electrophoresis》2005,26(2):376-382
We report here a novel triple injection method for microchip electrophoresis (micro-CE) that results in a higher intensity of DNA peaks. This new method includes a triple-repeated process of a combination of a sample loading voltage and a separation voltage in each interval, namely (loading time) + (separation time) + (loading time) + (separation time) + (loading time), prior to electrophoretic separation. All these injections were electrokinetically controlled by a software. Although the usual sample injection, which included the process of one 60 s electrokinetically application, was limited by the amount of sample, peaks of 40% higher intensity were obtained using the new method within half of the conventional injection time compared to the conventional method. Maximum peak intensity was successfully achieved with integration of the intensities of the triple-repeated peaks by adjusting the application period of the separation voltage. Repetition of the sample loading voltage for an adjusted period with a further adjusted period of separation voltage in each interval may be an effective method for injection of samples that results in peaks with higher intensity.  相似文献   

10.
Rapid separation of nucleic acids by microchip electrophoresis could streamline many biological applications, but conventional chip injection strategies offer limited sample stacking, and thus limited sensitivity of detection. We demonstrate the use of photopatterned polyacrylamide membranes in a glass microfluidic device, with or without fixed negative charges, for preconcentration of double-stranded DNA prior to electrophoretic separation to enhance detection limits. We compared performance of the two membrane formulations (neutral or negatively charged) as a function of DNA fragment size, preconcentration time, and preconcentration field strength, with the intent of optimizing preconcentration performance without degrading the subsequent electrophoretic separation. Little size-dependent bias was observed for either membrane formulation when concentrating dsDNA > 100 bp in length, while the negatively charged membrane more effectively blocks passage of single-stranded oligonucleotide DNA (20-mer ssDNA). Baseline resolution of a six-band dye-labeled ladder with fragments 100-2000 bp in size was obtained in <120 s of separation time, with peak efficiencies in the range of 2000-15,000 plates/cm, and detection limits as low as 1 pM per single dye-labeled fragment. The degree of preconcentration is tunable by at least 49-fold, although the efficiency of preconcentration was found to have diminishing returns at high field and/or long times. The neutral membrane was found to be more robust than the negatively charged membrane, with approximately 2.5-fold larger peak area during the subsequent separation, and less decrease in resolution upon increasing the preconcentration field strength.  相似文献   

11.
Xu Z  Ando T  Nishine T  Arai A  Hirokawa T 《Electrophoresis》2003,24(21):3821-3827
A microchip gel electrophoresis (MCGE) method with electrokinetic supercharging (EKS, electrokinetic injection with transient isotachophoresis) on a single channel chip was developed for high-sensitive detection of a standard mixture of six proteins (phosphorylase b, albumin, ovalbumin, carbonic anhydrase, trypsin inhibitor, and alpha-lactalbumin) in the form of sodium dodecyl sulfate (SDS) complexes. An average lower limit of detectable concentration (LLDC) achieved using UV detection at 214 nm was 0.27 microg/mL that is 30 times lower than that of conventional MCGE on a cross geometry chip. The calibration curves for molecular weight and concentration of SDS-protein complexes suggested that the present EKS-MCGE method had a better linear dynamic range and benefited future applications for qualitative and quantitative analysis of unknown protein samples. It was found that an excessive amount of unbound SDS in the sample deteriorated the preconcentration effect and resolution. The developed method appears greatly promising for high-speed and high sensitive analysis of SDS-proteins by MCGE.  相似文献   

12.
We evaluated a novel strategy for high-sensitivity DNA fragment analysis in a conventional glass double-T microfluidic chip. The microchip allows for a DNA on-channel concentration based on base stacking (BS) with a microchip capillary gel electrophoretic (MCGE) separation step in a poly(vinylpyrrolidone) (PVP) sieving matrix. Depending if low conductivity caused a neutralization reaction between the hydroxide ions and the run buffer component Tris+, the stacking of DNA fragments were processed in the microchip. Compared to a conventional MCGE separation with a normal electrokinetic injection, the peak heights of 50-2650-base pair (bp) DNA fragments on the MCGE-BS separation were increased 3.9-8.0-fold. When we applied the MCGE-BS method to the analysis of a clinical sample of bovine theileria after PCR reaction, the peak height intensity of the amplified 816-bp DNA fragment from the 18S rRNA of T. buffeli was enhanced 7.0-fold compared to that of the normal injection method.  相似文献   

13.
Huang H  Xu F  Dai Z  Lin B 《Electrophoresis》2005,26(11):2254-2260
A microchip for integrated isotachophoretic (ITP) preconcentration with gel electrophoretic (GE) separation to decrease the detectable concentration of sodium dodecyl sulfate (SDS)-proteins was developed. Each channel of the chip was designed with a long sample injection channel to increase the sample loading and allow stacking the sample into a narrow zone using discontinuous ITP buffers. The pre-concentrated sample was separated in GE mode in sieving polymer solutions. All the analysis steps including injection, preconcentration, and separation of the ITP-GE process were performed continuously, controlled by a high-voltage power source with sequential voltage switching between the analysis steps. Without deteriorating the peak resolution, four SDS-protein analyses with integrated ITP-GE system resulted in a decreased detectable concentration of approximately 40-fold compared to the GE mode only. A good calibration curve for molecular weights of SDS-proteins indicated that the integrated ITP-GE system can be used for qualitative analysis of unknown protein samples.  相似文献   

14.
This paper presents an inexpensive and easy-to-implement voltage sequencer instrument for use in microchip capillary electrophoresis (MCE) actuation. The voltage sequencer instrument takes a 0–5 V input signal from a microcontroller and produces a reciprocally proportional voltage signal with the capability to achieve the voltages required for MCE actuation. The unit developed in this work features four independent voltage channels, measures 105 × 143 × 45 mm (width × length × height), and the cost to assemble is under 60 USD. The system is controlled by a peripheral interface controller and commands are given via universal serial bus connection to a personal computer running a command line graphical user interface. The performance of the voltage sequencer is demonstrated by its integration with a fluorescence spectroscopy MCE sensor using pinched sample injection and electrophoretic separation to detect ciprofloxacin in samples of milk. This application is chosen as it is particularly important for the dairy industry, where fines and health concerns are associated with the shipping of antibiotic-contaminated milk. The voltage sequencer instrument presented represents an effective low-cost instrumentation method for conducting MCE, thereby making these experiments accessible and affordable for use in industries such as the dairy industry.  相似文献   

15.
Over the past years, the development of capillary electrophoresis (CE) and microchip electrophoresis (ME) systems has grown due to instrumental simplicity and wide application. In both CE and ME, the application of a high voltage (HV) is a crucial step in the electrokinetic (EK) injection and separation processes. Particularly on ME devices, EK injection is often performed with three different modes: gated, pinched, and unpinched. In all these cases, different potential values may be applied to one or multiple channels to control the injection of small sample volumes as well as the separation process. For this reason, the construction of reliable HV power supplies (HVPS) is required. This review covers the advances of the development of commercial and laboratory-built HVPS for CE and ME. Moreover, it intends to be a guide for new developers of electrophoresis instrumentation.  相似文献   

16.
This review discusses recent progress in the application of one of the most effective in-line preconcentration techniques used in electrophoresis in capillaries and microchips, electrokinetic supercharging (EKS). Conventionally considered as a transient isotachophoresis (tITP) step put into effect after the electrokinetic sample injection (EKI), EKS presumes that the electrolyte filled into the capillary (or microchip channel) comprises a co-ion acting as a leading ion to stack the injected analytes. Subsequently, to create the tITP state, one needs an additional injection of a suitable terminating ion. As a resulting increase in sensitivity strongly depends on the performance of both EKS stages, two theoretical sections are focused on hints for proper arrangement of EKI and tITP elaborated by means of computer simulation. In particular, factors affecting the injected amount of analytes, different modes of introducing the sample, suitable combinations of leading and terminating ions, and optimization of supporting electrolyte compositions are discussed with an objective to increase the enrichment factors. A comprehensive coverage of recent EKS applications in capillary and microchip electrophoresis, including metal ions, pharmaceuticals, peptides, DNA fragments, and proteins, demonstrates attainable sensitivity enhancements up to two orders of magnitude. This should make this method exportable to other analytes and facilitate its more widespread use to applications that require low limits of detection.  相似文献   

17.
Transient trapping (tr-trapping) was developed as one of the on-line sample preconcentration techniques to improve a low concentration-sensitivity in microchip electrophoresis (MCE), providing highly effective preconcentration and separation based on the trap-and-release mechanism. However, a poor performance to hydrophilic analytes limited the applicability of tr-trapping. To overcome this drawback, tr-trapping was combined with a sample labeling using a hydrophobic reagent in CE. Three commercially available fluorescent dyes, fluorescein isothiocyanate, succinimidyl esters of Alexa Fluor 488 and BODIPY FL-X, were tested as derivatization reagents to increase the hydrophobicity of amino acids (AAs) that were undetectable due to no fluorescence/UV-absorbance. As a result, it was confirmed that BODIPY labeling allowed various AAs to be analyzed in tr-trapping-micellar electrokinetic chromatography (tr-trapping-MEKC) by the increase in the hydrophobicity. In tr-trapping-MEKC, both the improvement of the resolution and 106-125-fold enhancements of the detectability of labeled AAs were achieved relative to the conventional capillary zone electrophoresis. The limit of detection of labeled phenylalanine was improved from 800 to 5 pM by applying tr-trapping-MEKC. In tr-trapping-microchip MEKC, furthermore, an 80-160-fold enhancement of the peak intensity and a baseline separation was also achieved within 30 s. These results clearly demonstrate that the tr-trapping technique with hydrophobic labeling will make CE/MCE more sensitive for various analytes.  相似文献   

18.
This research examines microchip electrophoresis with linear imaging UV detection for the analysis of antimicrobial metabolites, monoacetylphloroglucinol (MAPG) and 2,4-diacetylphloroglucinol (2,4-DAPG) from Pseudomonas fluorescens F113. Initial results show the separation of MAPG, 2,4-DAPG and resorcinol in less than 20 s. This was achieved using a quartz microchip with a separation channel length of 25 mm. In order to quantitate the amount of MAPG and 2,4-DAPG in a microbial cultured supernatant sample, on-chip sample introduction in a methanol/buffer matrix was investigated. Sample introduction/injection parameters were optimized to improve sensitivity and thus decrease the limit of detection (LOD). The amount of antimicrobial metabolites present was quantitated with a separation time of 15 s. A previously developed capillary electrophoretic method was compared to the microchip method in relation to speed, efficiency, precision, linear range and limit of detection. This investigation shows the fastest separation so far of these antimicrobial metabolites with high efficiency.  相似文献   

19.
Electrokinetic supercharging (EKS) is considered as one of the most powerful online preconcentration techniques in electrophoresis. It combines the efficient preconcentration power of field-amplified sample injection and the exceptional selective nature of transient isotachophoresis. It has a wide range of applications to different types of analytes ranging from small ions to large proteins and DNA fragments. This comprehensive review--up to date--provides listing for all the works, developments, and advances in EKS. The review will pay particular attention to innovations, new methodologies for manipulation, challenges for improving the detection sensitivity, and various applications of EKS in capillaries and microchips.  相似文献   

20.
The fabrication of a battery operated 3-channel high voltage power supply for microchip capillary electrophoresis is described. The power supply consists of two positive and one negative DC-DC converters, a microprocessor controlled timer, a battery and a transformer to recharge the battery and feed the high voltage relays. This arrangement allows the possibility to control the potentials applied in the 0 to +/-4000 V range to a variety of microchip setups. It can also be easily adapted to perform either gated or pinched injection. The inclusion of a rechargeable battery was adopted to feed the DC-DC converters to reduce noise levels and achieve portability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号