首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We installed a cold‐spray ionization (CSI) source on a mass spectrometer to investigate the self‐assembly behavior of an aggregation‐induced emission enhancement system. Using a CSI source and the three‐dimensional platform, a self‐assembly system of a salicylaldehyde azine (SAA) was studied in mixture solution. This method permitted the determination of the structural information of the solution state, which cannot be detected by conventional mass spectrometry. In addition to the [M+H]+ ion (M is the SAA molecule), many major ion clusters such as [2M+Na]+ at m/z 503, [3M+Na]+ at m/z 743, [4M+Na]+ at m/z 983 and higher order aggregates were observed in the CSI mass spectra. However, many fragment ions, with the exception of cluster ions, appeared with high abundance when the ESI ion source was used due to the desolvation chamber temperature, suggesting that some aggregation can be detected at low temperatures. To investigate the effect of solvent on the aggregation, the CSI‐mass spectrometry (MS) experiments of SAA in absolute ethanol solution and ethanol/water (good/poor solvent) mixture solution were conducted. The most abundant ion peak was protonated SAA (m/z 241) in absolute ethanol, but many cluster ions and some multiple charged ion peaks were observed after adding a small amount of water into the ethanol solution. The results showed good agreement with that inferred by the combinational analysis of scanning electron microscope and fluorescence microscopy, indicating that CSI‐MS is capable of providing self‐assembly information of labile molecules in the solution state. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
Within this paper a sub-group of ambient ionization mass spectrometry namely direct ionization mass spectrometry techniques are reviewed. They are characterized by the generation of an electrospray directly from the sample investigated. Prominent representatives include paper spray mass spectrometry, tissue spray mass spectrometry, probe electrospray ionization or thin-layer chromatography mass spectrometry. Applications of all major direct ionization techniques within different fields such as biomedical analysis, analysis of natural products, analysis of technical products and food analysis, just to name a few, are discussed and relevant parameters are listed in five Tables.  相似文献   

3.
A new integrated microchip for liquid chromatography-mass spectrometry (LC-MS) is presented. The chip is made from bonded silicon and glass wafers with structures for a packed LC column channel, a micropillar frit, a channel for optional optical detection, and a heated vaporizer section etched in silicon and platinum heater elements on the glass cover. LC eluent is vaporized and mixed with nebulizer gas in the vaporizer section and the vapor is sprayed out from the chip. Nonpolar and polar analytes can be efficiently ionized in the gas phase by atmospheric pressure photoionization (APPI) as demonstrated with polycyclic aromatic hydrocarbons (PAHs) and selective androgen receptor modulators (SARMs). This is not achievable with present LC-MS chips, since they are based on electrospray ionization, which is not able to ionize nonpolar compounds efficiently. The preliminary quantitative performance of the new chip was evaluated in terms of limit of detection (down to 5 ng mL−1), linearity (r > 0.999), and repeatability of signal response (RSD = 2.6-4.0%) and retention time (RSD = 0.3-0.5%) using APPI for ionization and PAHs as standard compounds. Determination of fluorescent compounds is demonstrated by using laser-induced fluorescence (LIF) for detection in the optical detection channel before the vaporizer section.  相似文献   

4.
5.
A direct solution analysis method, cold-spray ionization (CSI) mass spectrometry (MS), a variant of electrospray (ESI) MS operating at low temperature (ca -80 to 10 degrees C), allows the facile and precise characterization of labile organic species, especially those in which non-covalent bonding interactions are prominent. We applied this method to investigations of the solution structures of many labile organic species, including unstable reagents and reaction intermediates, asymmetric catalysts, supramolecules and even primary biomolecules. Remarkable analytical results were obtained for highly ordered supramolecules using the CSI method. Whereas conventional ESI is not applicable to these compounds because of their instability to heat and/or air, CSI affords multiply charged molecular ions with many solvent molecules attached. Investigation of the constitution of Grignard reagents in solution is extremely challenging, but CSI-MS allowed us to identify one of the key structures in THF solution. Recently, this method was adopted for investigations of the solution structures of primary biomolecules such as nucleosides, amino acids, sugars and lipids, revealing singly charged Na(+) adducts of large clusters (chain structures), presumably linked by non-covalent interactions, including hydrogen bonding and/or hydrophobic interactions. The principle of the CSI method and applications of the method to a wide variety of labile organic species and primary biomolecules in solution are described.  相似文献   

6.
In this work, ion mobility spectrometry (IMS) function as a detector and another dimension of separation was coupled with CE to achieve two‐dimensional separation. To improve the performance of hyphenated CE‐IMS instrument, electrospray ionization correlation ion mobility spectrometry is evaluated and compared with traditional signal averaging data acquisition method using tetraalkylammonium bromide compounds. The effect of various parameters on the separation including sample introduction, sheath fluid of CE and drift gas, data acquisition method of IMS were investigated. The experimental result shows that the optimal conditions are as follows: hydrodynamic sample injection method, the electrophoresis voltage is 10 kilo volts, 5 mmol/L ammonium acetate buffer solution containing 80% acetonitrile as both the background electrolyte and the electrospray ionization sheath fluid, the ESI liquid flow rate is 4.5 μL/min, the drift voltage is 10.5 kilo volts, the drift gas temperature is 383 K and the drift gas flow rate is 300 mL/min. Under the above conditions, the mixture standards of seven tetraalkylammoniums can be completely separated within 10 min both by CE and IMS. The linear range was 5–250 μg/mL, with LOD of 0.152, 0.204, 0.277, 0.382, 0.466, 0.623 and 0.892 μg/mL, respectively. Compared with traditional capillary electrophoresis detection methods, the developed CE‐ESI‐IMS method not only provide two sets of qualitative parameters including electrophoresis migration time and ion drift time, ion mobility spectrometer can also provide an additional dimension of separation and could apply to the detection ultra‐violet transparent compounds or none fluorescent compounds.  相似文献   

7.
The ability to rapidly identify and quantitate, over a wide range of concentrations, anthocyanins in food and therapeutic products is important to ensuring their presence at medicinally significant levels. Sensitive, yet mild, analysis conditions are required given their susceptibility to degradation and transformation. Paper spray ionization has been used to detect and quantify the levels of anthocyanin levels in extracts of fresh and dried elderberries, and elderberry stems, as well as 3 commercially available nutraceutical formulations. The component cyanidin glucosides, including cyanidin‐3‐sambubioside, cyanidin‐3‐glucoside, cyanidin‐3,5‐diglucoside, cyanidin‐3‐sambubioside‐5‐glucoside, and the aglycone cyanidin, were readily detected in a range of sources. Quantitation was achieved by establishing a calibration plot from dilutions of a stock solution of cyanidin‐3,5‐diglucoside containing malvidin‐3,5‐diglucoside as an internal standard at a fixed concentration. The same standard was used to quantify the anthocyanin content in the fruit and nutraceutical formulations. Wide 5‐fold variations in anthocyanin concentration were detected in the nutraceutical formulations from different suppliers ranging from 1050 to 5430 mg/100 g. These concentrations compared with 500 to 2370 mg/100 g measured in the dried stems and fruit, respectively.  相似文献   

8.
The direction of the effective electrophoretic mobility of small organic cations in micellar electrokinetic chromatography using sodium dodecyl sulphate in a low-pH electrolyte can be reversed in the presence of organic solvent. This effective electrophoretic mobility change is presented here as a new dimension for on-line sample preconcentration of cations in capillary zone electrophoresis (CZE) using a background solution (BGS) modified by an organic solvent. The sample is prepared in a micellar solution without organic solvent. The focusing effect relies on the reversal in the effective electrophoretic mobility at the boundary zone between the micellar matrix and the BGS modified with organic solvent. This on-line sample preconcentration technique, called micelle to solvent stacking (MSS) afforded more than an order of magnitude improvement in concentration sensitivity compared to typical CZE-UV or CZE-electrospray ionization (ESI) MS analysis. The calculated limit of detection (S/N = 3) for pindolol and metoprolol analysed by MSS-CZE-ESI-MS was found to be 0.03 and 0.01 μg/mL, respectively.  相似文献   

9.
A novel method for speciation analysis of inorganic arsenic was developed by on-line hyphenating microchip capillary electrophoresis (chip-CE) with hydride generation atomic fluorescence spectrometry (HG-AFS). Baseline separation of As(III) and As(V) was achieved within 54 s by the chip-CE in a 90 mm long channel at 2500 V using a mixture of 25 mmol l(-1) H3BO3 and 0.4 mmol l(-1) CTAB (pH 8.9) as electrolyte buffer. The precisions (RSD, n=5) ranged from 1.9 to 1.4% for migration time, 2.1 to 2.7% for peak area, and 1.8 to 2.3% for peak height for the two arsenic species at 3.0 mg l(-1) (as As) level. The detection limits (3sigma) for As(III) and As(V) based on peak height measurement were 76 and 112 microg l(-1) (as As), respectively. The recoveries of the spikes (1 mg l(-1) (as As) of As(III) and As(V)) in four locally collected water samples ranged from 93.7 to 106%.  相似文献   

10.
The online coupling of microchip electrophoresis (ME) as a fast, highly efficient, and low-cost miniaturized separation technique to mass spectrometry (MS) as an information-rich and sensitive characterization technique results in ME–MS an attractive tool for various applications. In this paper, we review the basic concepts and latest advances in technology for ME coupled to MS during the period of 2016–2021, covering microchip materials, structures, fabrication techniques, and interfacing to electrospray ionization (ESI)–MS and matrix-assisted laser desorption/ionization–MS. Two critical issues in coupling ME and ESI–MS include the electrical connection used to define the electrophoretic field strength along the separation channel and the generation of the electrospray for MS detection, as well as, a miniaturized ESI-tip. The recent commercialization of ME–MS in zone electrophoresis and isoelectric focusing modes has led to the widespread application of these techniques in academia and industry. Here we summarize recent applications of ME–MS for the separation and detection of antibodies, proteins, peptides, carbohydrates, metabolites, and so on. Throughout the paper these applications are discussed in the context of benefits and limitations of ME–MS in comparison to alternative techniques.  相似文献   

11.
Fourteen common drugs of abuse were identified in spiked oral fluid (ng mL−1 levels), analyzed directly from medical swabs using touch spray mass spectrometry (TS-MS), exemplifying a rapid test for drug detection. Multiple stages of mass analysis (MS2 and MS3) provided identification and detection limits sought by international forensic and toxicological societies, Δ9-THC and buprenorphine excluded. The measurements were made using a medical swab as both the sampling probe and means of ionization. The adaptation of medical swabs for TS-MS analysis allows non-invasive and direct sampling of neat oral fluid. Data acquisition was rapid, seconds per drug, and MS3 ensured reliable identification of illicit drugs. The reported data were acquired to investigate (i) ionization of common drugs from commercial swabs, (ii) ion intensity over spray duration, and (iii) dynamic range, all as initial steps in development of a quantitative method. The approach outlined is intended for point-of-care drug testing using oral fluid in clinical applications as well as in situ settings, viz. in forensic applications. The proof-of-concept results presented will require extension to other controlled substances and refinement in analytical procedures to meet clinical/legal requirements.  相似文献   

12.
Capillary zone electrophoresis coupled with electrospray ionization mass spectrometry (CZE–ESI-MS) has been applied for the first time for the separation and quantification of isoflavones in soy products. The proposed method was successfully applied to the determination of seven isoflavones, including aglycones and glucosides, in soy drink. The target compounds were the glucosides daidzin and genistin, and the aglycones daidzein, genistein, formononetin, biochanin A and glycitein. During CE separation in positive mode, the analytes were present as anions, and MS detection was carried out in ESI positive-ion mode. To prevent the frequent drops in current and to improve the resolution in the separation of analytes in anionic form, a programmed nebulizing gas pressure (PNP) was applied along the analysis.  相似文献   

13.
张颖  王红 《分析试验室》2007,26(5):62-64
PEPAMP是应用于工业循环水中的新一代高效阻垢剂.采用电喷雾电离质谱和质谱/质谱技术分析了合成产物,注射泵直接进样,正离子方式检测,方法简便、快速.通过EI-MS技术获得了目标产物PEPAMP及主要副产物的准分子离子峰,通过ESI-MS-MS技术获得了其碎片信息,并对目标化合物及主要副产物进行了精确质量测定,确定了目标化合物及主要副产物的结构.  相似文献   

14.
We report on the coupling of a polymer-based microfluidic chip to a MALDI-TOF MS using a rotating ball interface. The microfluidic chips were fabricated by micromilling a mold insert into a brass plate, which was then used for replicating polymer microparts via hot embossing. Assembly of the chip was accomplished by thermally annealing a cover slip to the embossed substrate to enclose the channels. The linear separation channel was 50 microm wide, 100 microm deep, and possessed an 8 cm effective length separation channel with a double-T injector (V(inj) = 10 nL). The exit of the separation channel was machined to allow direct contact deposition of effluent onto a specially constructed rotating ball inlet to the mass spectrometer. Matrix addition was accomplished in-line on the surface of the ball. The coupling utilized the ball as the cathode transfer electrode to transport sample into the vacuum for desorption with a 355 nm Nd:YAG laser and analyzed on a TOF mass spectrometer. The ball was cleaned online after every rotation. The ability to couple poly(methylmethacrylate) microchip electrophoresis devices for the separation of peptides and peptide fragments produced from a protein digest with subsequent online MALDI MS detection was demonstrated.  相似文献   

15.
Implementation and optimization of an off-line capillary electrophoresis (CE)/(−)nanoESIchip-quadrupole time-of-flight (QTOF) mass spectrometric (MS) and tandem MS system for compositional mapping and structural investigation of components in complex carbohydrate mixtures is described. The approach was developed for glycoscreening and applied to O-glycosylated peptides from urine of a patient suffering from α-N-acetylhexosaminidase deficiency, known as Schindler's disease. The fundamental issue of sensitivity, previously representing a serious drawback of the off-line CE/MS analysis, could be positively addressed by the off-line conjunction of CE with automated chip-based ESI-QTOF-MS to provide flexibility for CE/chip MS coupling and enhance structural elucidation of single components in heterogeneous mixtures. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

16.
Chemical speciation (extraction of elemental information and identification of molecular environment for an analyte in a complex sample) has been a long sought after goal for analytical chemists. Recently, because of successful developments in more sensitive element-specific detectors and gentle separation schemes, which preserve the true chemical information in a real sample, routine speciation experiments are becoming a common occurrence in the scientific literature. For many reasons, the combination of capillary electrophoresis (for separation of different chemical species) with inductively coupled plasma mass spectrometry (for element and isotope specific detection) has emerged as the method of choice for these analyses. In this article the basic principles of capillary electrophoresis inductively coupled plasma mass spectrometry are discussed. Design consideration for instrument interface, anticipated difficulties with speciation experiments and applications for specific matrices and analytes are also presented in this article.  相似文献   

17.
On‐surface degradation of sildenafil (an adequate substrate as it contains assorted functional groups in its structure) promoted by the Fenton (Fe2+/H2O2) and Fenton‐like (Mn+/H2O2; Mn+ = Fe3+, Co2+, Cu2+, Mn2+) systems was investigated by using paper spray ionization mass spectrometry (PS‐MS). The performance of each system was compared by measuring the ratio between the relative intensities of the ions of m/z 475 (protonated sildenafil) and m/z 235 (protonated lidocaine, used as a convenient internal standard and added to the paper just before the PS‐MS analyzes). The results indicated the following order in the rates of such reactions: Fe2+/H2O2 ≫ H2O2 ≫ Cu2+/H2O2 > Mn+/H2O2 (Mn+ = Fe3+, Co2+, Mn2+) ~ Mn+ (Mn+ = Fe2+, Fe3+, Co2+, Cu2+, Mn2). The superior capability of Fe2+/H2O2 in causing the degradation of sildenafil indicates that Fe2+ efficiently decomposes H2O2 to yield hydroxyl radicals, quite reactive species that cause the substrate oxidation. The results also indicate that H2O2 can spontaneously decompose likely to yield hydroxyl radicals, although in a much smaller extension than the Fenton system. This effect, however, is strongly inhibited by the presence of the other cations, ie, Fe3+, Co2+, Cu2+, and Mn2+. A unique oxidation by‐product was detected in the reaction between Fe2+/H2O2 with sildenafil, and a possible structure for it was proposed based on the MS/MS data. The on‐surface reaction of other substrates (trimethoprim and tamoxifen) with the Fenton system was also investigated. In conclusion, PS‐MS shows to be a convenient platform to promptly monitor on‐surface oxidation reactions.  相似文献   

18.
Interaction of carboplatin with cytochrome c (Cyt. c) has been investigated by electrospray ionization mass spectrometry (ESI-MS) and tandem mass spectrometry (MS/MS). ESI-MS studies revealed that the ring-opened adducts of carboplatin with Cyt. c were formed in the stoichiometric ratio of 1:1 and 2:1 at pH 5.0 and 37 degrees C and in the stoichiometric ratio of 1:1 only at pH 7.0 and 37 degrees C. It was also found that Cyt. c could be cleaved by carboplatin at pH 2.5 and 50 degrees C. The cleaved fragments of Cyt. c were determined by ESI-MS and MS/MS analysis to be Glu66 approximately Met80, Ac-Gly01 approximately Met65, Glu66 approximately Glu104, Ac-Gly01 approximately Met80 and Ile81 approximately Glu104. The carboplatin prefers to anchor to Met65 first, then to Met80. To further confirm the binding site of Met, AcMet-Gly was used as the model molecule to investigate its interaction with carboplatin and its hydrolysis reaction. On the basis of species detected during the reaction monitored by ESI-MS, a possible pathway of the cleavage reaction was proposed.  相似文献   

19.
张四纯  张新荣 《中国科学:化学》2014,(5):32-34,683,686
敞开式离子化质谱可对表面样品进行直接快速分析而受到关注,成为质谱分析的热点研究方向.介质阻挡放电离子源是一种基于等离子体放电机理的敞开式离子源,近年来得到了较快的发展.本文着重介绍该离子源的基本原理、性能特征以及应用进展,并对其发展趋势进行了展望.  相似文献   

20.
Pogue RT  Majidi V 《Talanta》1996,43(12):2143-2149
In this paper, we introduce laser desorption X-ray ionization for producing ions from the previously undetected neutral species present during laser desorption mass spectrometry. Studies involving the laser desorption of simple sugars were conducted to illustrate the differences between spectra with and without the X-ray source. Ionization was made possible by placing a 200 mCi Am X-ray source directly into the ionization chamber of a time-of-flight mass spectrometer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号