首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
We have studied the trans-membrane electron transfer in human red blood cells (RBCs) immobilized in a chitosan film on a glassy carbon electrode (GCE). Electron transfer results from the presence of hemoglobin (Hb) in the RBCs. The electron transfer rate (k s) of Hb in RBCs is 0.42 s?1, and <1.13 s?1 for Hb directly immobilized in the chitosan film. Only Hb molecules in RBCs that are closest to the plasma membrane and the surface of the electrode can undergo electron transfer to the electrode. The immobilized RBCs displayed sensitive electrocatalytic response to oxygen and hydrogen peroxide. It is believed that this cellular biosensor is of potential significance in studies on the physiological status of RBCs based on observing their electron transfer on the modified electrode.
The transmembrane electron transfer rate of Hb in RBCs is slower than hemoglobin molecules directly immobilized on the chitosan film. Only those hemoglobin in RBCs closest to the plasma membrane and electrode could exchange electrons with the electrode. The immobilized RBCs showed sensitive electrocatalytic response to O2 and H2O2.  相似文献   

2.
Yaping Li 《Mikrochimica acta》2012,177(3-4):443-447
We report on a new scheme for the determination of the activity of caspase-3 using a specific peptide labeled with N-(4-aminobutyl)-N-ethylisoluminol (ABEI) as a chemiluminescent (CL) probe and on the development of magnetic separation technology. Firstly, the ABEI-labeled and biotinylated peptide was prepared and conjugated to streptavidin-coated magnetic beads (MBs) to form f-MBs (functionalized magnetic beads). The f-MBs contain a site (DEVD, Asp-Glu-Val-Asp) that is cleaved by caspase-3. Upon cleavage, the terminal residue attached to ABEI can dissociate from the f-MBs and can be used for CL detection. CL intensity is linearly related to the concentration of caspase-3 in the range 1.0 to 600 ng mL?1, with a detection limit of 0.3 ng mL?1. The relative standard deviation of the assay is 3.6 % at a level of 50 ng mL?1 of caspase-3 (for n?=?11). The CL assay has been applied to the determination of caspase-3 in Jurkat cell extract with recoveries between 96.6 % and 106.1 % (n?=?5).
Figure
A chemiluminescence assay for the detection of caspase-3 activity using N-(4-aminobutyl)-N-ethylisoluminol labeled specific peptide as CL probe coupling the magnetic separation technology was developed. The developed method has been applied to determination of caspase-3 in Jurkat cells extract with a satisfactory.  相似文献   

3.
We have developed a simple method for the extraction of sulfonylurea herbicides (SUHs) from environmental water samples. It is based on a magnetic molecular imprint (MMIP) as a sorbent. The MMIP was prepared using metsulfuron-methyl as the template molecule, methacrylic acid as the functional monomer, trimethylolpropane trimethacrylate as the cross-linking agent, and magnetite as the magnetic component. Extraction can be carried out by blending and stirring water sample, extraction solvent and MMIP. Once the extraction is completed, the MMIP containing the SUHs can be separated from the sample matrix with a magnet. The SUHs desorbed from the polymers were then quantified by capillary liquid chromatography with diode array detection. The limits of quantification are in the range of 0.08 to 0.1 ng?mL?1. Repeatabilities of peak areas and retention times range from 2.9 % to 4.0 % and from 0.1 % to 0.3 %, respectively. The method was successfully applied to the determination of the SUHs bensulfuron-methyl, metsulfuronmethyl, pyrazosulfuron-methyl, thifensulfuron-methyl, and triasulfuron in waste water samples. Recoveries range from 94.3 % to 102.3 %.
Figure
Scheme of sulfonylurea herbicide preconcentration  相似文献   

4.
The fluorescence quenching of quantum dots by hemoglobin has been demonstrated to depend on surface functionalization, and this property has been utilized to construct a novel fluorescent method for rapid, sensitive, and selective detection of trace hemoglobin in urine at microgram level. This method shows low interference and high selectivity for hemoglobin with a limit of detection of 4.3 μg L?1 in water and 66.1 μg L?1 in urine, which are lower than those of currently used methods in labs and clinics. Spike and recovery tests in raw, acidified, and alkalized urine samples exhibit good recovery rates for the spiked concentrations close to the limit of detection.
Figure
Fluorescence spectra and photographs of MPA-QD solution before and after the addition of Hb taken under 365-nm irradiation.  相似文献   

5.
A new method was developed for the speciation of inorganic arsenic in environmental water by using selective magnetic solid-phase extraction followed by inductively coupled plasma mass spectrometry. It is found that As(V) selectively adsorbed on amino-modified silica-coated magnetic nanoparticles (MNPs) in the pH range from 3 to 8, while As(III) is not be retained. The As(V)-loaded MNPs can be separated easily from the aqueous sample solution by simply applying an external magnetic field. The adsorbed As(V) was quantitatively recovered from the MNPs using using 1 M nitric acid. Total inorganic As was extracted after the permanganate oxidation of As(III) to As(V). Parameters affecting the separation were investigated systematically, and the optimal separation conditions were established. Under the optimal conditions, the limit of detection is 0.21 ng L?1, and the precision is 6.8% (at 10 ng L?1, for n?=?7). The method was applied to the speciation of inorganic arsenic in environmental water of tobacco growing area.
Figure
A new kind of silica-coated magnetic nanoparticles (SCMNPs) modified with AAPTS was synthesized and employed as magnetic solid phase extraction adsorbent for ICP-MS speciation of inorganicAs in environmental water  相似文献   

6.
This work describes a comparison of three types of commercial high-performance liquid chromatography silica monolithic columns with different inner diameters and generations of monolithic sorbent: a “classic” monolithic column, the first generation (Onyx? monolithic C18, 100 mm?×?4.6 mm, Phenomenex); a “narrow” monolithic column for fast separation at lower flow rates (Chromolith® Performance RP-18e, 100 mm?×?3 mm, Merck); and a recently introduced “high-resolution” monolithic column, the next generation (Chromolith® HighResolution RP-18e, 100 mm?×?4.6 mm, Merck). Separation efficiency (number of theoretical plates, height equivalent to a theoretical plate and van Deemter curves), working pressure, the symmetry factor and resolution were critical aspects of the comparison in the case of the separation of ascorbic acid, paracetamol and caffeine. The separations were performed under isocratic conditions with a mobile phase consisting of 10:90 (v/v) acetonitrile–phosphoric acid (pH 2.80). Detailed comparison of the newest-generation monolithic column (Chromolith® HighResolution) with the previously introduced monolithic sorbents was performed and proved the advantages of the Chromolith® HighResolution column.
Figure
Chromatogram of separation using different flow rates (corresponded to optimal separation conditions); 1 0.5 mL?min-1; 2 0.6 mL?min-1; 3 0.3 mL?min-1  相似文献   

7.
The glycation level at β-Val-1 of the hemoglobin β chain in human blood (HbA1c%) is used to diagnose diabetes and other diseases. However, hemoglobin glycation occurs on multiple sites on different isoforms with different kinetics, but its differential profile has not been clearly demonstrated. In this study, hemoglobin was extracted from the blood of normal and diabetic individuals by protein precipitation. Triplicate solutions prepared from each sample were directly analyzed or digested with multiple enzymes and then analyzed by nano-LC/MS via bottom-up approach for side-by-side characterization. Intact hemoglobin analysis indicated a single glucose-dominant glycation, which showed good correlation with the HbA1c% values. Moreover, full sequence (100 %) of α/β globin was mapped and seven glycation sites were unambiguously assigned. In addition to β-Val-1, two other major sites at α-Lys-61 and β-Lys-66, which contain the common sequence HGKK, and four minor sites (<1 %) on α-Val-1, β-Lys-132, α-Lys-127, and α-Lys-40 were identified. All sites were shown to exhibit similar patterns of site distribution despite different glucose levels. Both the intact mass measurement and bottom-up data consistently indicated that the total glycation percentage of the β-globin was twice higher than the α-globin. Using molecular modeling, the 3D structure of the consensus sequence (HGKK) was shown to contain a phosphate triangle cavity, which helps to catalyze the glycation reaction. For the first time, hemoglobin glycation in normal and diabetic bloods was comparatively characterized in-depth with 100 % sequence coverage. The results provide insight about the HbA1c parameter and help define the new and old markers.
Figure
?  相似文献   

8.
The performance of differential IMS (FAIMS) analyzers is much enhanced by gases comprising He, especially He/N2 mixtures. However, electrical breakdown has limited the He fraction to ~50 %–75 %, depending on the field strength. By the Paschen law, the threshold field for breakdown increases at shorter distances. This allows FAIMS using chips with microscopic channels to utilize much stronger field intensities (E) than “full-size” analyzers with wider gaps. Here we show that those chips can employ higher He fractions up to 100 %. Use of He-rich gases improves the resolution and resolution/sensitivity balance substantially, although less than for full-size analyzers. The optimum He fraction is ~80 %, in line with first-principles theory. Hence, one can now measure the dependences of ion mobility on E in pure He, where ion-molecule cross section calculations are much more tractable than in other gases that form deeper and more complex interaction potentials. This capability may facilitate quantitative modeling of high-field ion mobility behavior and, thus, FAIMS separation properties, which would enable a priori extraction of structural information about the ions.
Figure
?  相似文献   

9.
This study demonstrates an untested link between model phenolic compounds and the formation/electrophoretic separation of stable urinary metabolites. Sterically encumbered carbonyl groups were examined, and mass determination was used to confirm the presence and stability of two oxidative metabolites of pentachlorophenol: tetrachloro-1,2-benzoquinone and tetrachloro-1,4-dihydroquinone. Subsequently, baseline resolved separation of pentachlorophenol and the two oxidative metabolites was demonstrated under the following conditions: 75 mM sodium tetraborate buffer (pH?=?8.5) with 5 % methanol and 50 mM SDS, +10.0 kV running voltage, injection time?=?5.0 s, effective capillary length?=?55 cm, and run temperature?=?20 °C. Results not only provide key metabolic inferences for pentachlorophenol, they also exhibit improvements in the ability to separate and detect changes in urinary metabolites in response to phenolic-related exposure.
Figure
Metabolic pathway elucidation towards time- and dose-dependent electrophoretic screening of stable oxidative phenolic compounds. Establishing direct pathways and developing sensitive/selective analytical tools to measure and characterize xenobiotics provides a defined link between potential hazards and suspected health effects.  相似文献   

10.
Despite the rapid development of nanomaterials and nanotechnology, it is still desirable to develop novel nanoparticle-based techniques which are cost-effective, timesaving, and environment-friendly, and with ease of operation and procedural simplicity, for assay of target analytes. In the work discussed in this paper, the dye fluorescein isothiocyanate (FITC) was conjugated to 1,6-hexanediamine (HDA)-capped iron oxide magnetic nanoparticles (FITC–HDA Fe3O4 MNPs), and the product was characterized. HDA ligands on the surface of Fe3O4 MNPs can bind 2,4,6-trinitrotoluene (TNT) to form TNT anions by acid–base pairing interaction. Formation of TNT anions, and captured TNT substantially affect the emission of FITC on the surface of the Fe3O4 MNPs, resulting in quenching of the fluorescence at 519 nm. A novel FITC–HDA Fe3O4 MNPs-based probe featuring chemosensing and magnetic separation has therefore been constructed. i.e. FITC–HDA Fe3O4 MNPs had a highly selective fluorescence response and enabled magnetic separation of TNT from other nitroaromatic compounds by quenching of the emission of FITC and capture of TNT in aqueous solution. Very good linearity was observed for TNT concentrations in the range 0.05–1.5 μmol?L?1, with a detection limit of 37.2 nmol?L?1 and RSD of 4.7 % (n?=?7). Approximately 12 % of the total amount of TNT was captured. The proposed methods are well-suited to trace detection and capture of TNT in aqueous solution.
Figure
Iron oxide magnetic nanoparticles-based selective fluorescent response and magnetic separation probe for 2,4,6-trinitrotoluene  相似文献   

11.
We have constructed a new electrochemical biosensor by immobilization of hemoglobin (Hb) and ZnWO4 nanorods in a thin film of chitosan (CTS) on the surface of carbon ionic liquid electrode. UV–vis and FT-IR spectra reveal that Hb remains in its native conformation in the film. The modified electrode was characterized by scanning electron microscopy, electrochemical impedance spectroscopy and cyclic voltammetry. A pair of well-defined redox peaks appears which indicates direct electron transfer from the electrode. The presence of CTS also warrants biocompatibility. The electron transfer coefficient and the apparent heterogeneous electron transfer rate constant were calculated to be 0.35 and 0.757 s?1, respectively. The modified electrode displays good electrocatalytic activity for the reduction of trichloroacetic acid with the detection limit of 0.613 mmol L?1 (3σ). The results extend the protein electrochemistry based on the use of ZnWO4 nanorods.
Figure
A ZnWO4 nanorods and hemoglobin nanocomposite material modified carbon ionic liquid electrode was used as the platform for the construction of an electrochemical hemoglobin biosensor.  相似文献   

12.
Qiang Zhao  Jie Gao 《Mikrochimica acta》2013,180(9-10):813-819
We describe a fluorogenic assay for activated protein C (APC) by using magnetic beads modified with DNA aptamers, taking advantage of strong binding affinity of aptamer, facile magnetic separation, and signal amplification via an enzymatic reaction. APC is specifically captured from a sample by the DNA aptamers on magnetic beads, and the concentrated APC then catalyzes the conversion of a fluorogenic substrate of APC to a fluorescent product. Detection of APC is achieved by measuring the generated product. This method is simple, sensitive, and specific. APC can be detected at 0.4 pM concentration level in a sample volume of 250 μL, corresponding to 0.1 femtomole of APC, when 2-h enzymatic reaction is employed. The proteins thrombin, trypsin, proteinase K, chymotrypsin, and elastase do not interfere.
Figure
An aptamer-based assay for human activated protein C (APC) is developed. APC is specifically captured from sample mixture by the aptamers on magnetic beads, and the captured APC converts substrate to product. Measurement of the generated product allows the determination of APC.  相似文献   

13.
We describe a simple method for the synthesis of highly magnetic and fluorescent bifunctional chitosan nanoparticles (MF-CSNPs). Water-soluble and magnetic Fe3O4-chitosan nanoparticles and CdSe quantum dots capped with thioglycolic acid were incorporated into a chitosan matrix via electrostatic interaction. The optical, magnetic, crystallographic and morphological properties of the new nanoparticles were studied by UV-visible, fluorescence, X-ray diffraction and transmission electron microscopy. In addition, MF-CSNPs are found to be a useful probe for the determination of copper ion which acts as a quencher of fluorescence. The relative fluorescence intensity of MF-CSNPs is linearly related to the concentration of copper ion in the 0.125 to 25 ng·mL-1 concentration range. The MF-CSNPs also are found to adsorb copper ion which therefore can be separated and enriched by manipulating them with an external magnetic field. Before enrichment, the limit of detection (LOD) for copper ion is 120 pg·mL-1, but after enrichment, the LOD is 46 pg·mL-1.
Figure
High magnetic and fluorescent bifunctional chitosan nanoparticles (MF-CSNPs) have been successfully synthesized via electrostatic interaction. MF-CSNPs are shown to represent a quenchable fluorescent probe for the detection of copper ion in water solution.  相似文献   

14.
We describe an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. A 300-μm-diameter platinum disc working electrode was embedded in a titanium tube which provides an adequate holding for working electrode and acts as counter electrode. We also have designed a simplified detection cell with a guide channel for the electrode. The integrated working-counter electrode can be easily aligned to the outlet of the separation channel through the guide channel. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3). The system was further applied to the determination of chlorpromazine hydrochloride in pharmaceutical formulations. The system is believed to have potential applications in pharmaceutical analysis.
Figure
We described an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3).  相似文献   

15.
We describe the synthesis of ß-cyclodextrin modified magnetic nanoparticles (CD-mNPs) as a material for solid-phase extraction of the cancer biomarker 5-hydroxy-indole-3-acetic acid (5-HIAA) from urine. The CD-mNPs were characterized by TEM, FTIR, and XRD, and the kinetics and adsorption isotherms were studied. The strong interaction between the CD-mNPs and 5-HIAA is the main driving force for recognition and extraction, while the magnetic core of the NPs allows their separation from the sample matrix. Recovery of 5-HIAA from the adsorbent using an adequate solvent regenerated the adsorbent for further use. 5-HIAA was then quantified by fluorometry of its complex with ß-CD. The method works in the 1?×?10?7 to 1?×?10?5 mol L?1 (R2 0.9982–0.9996) concentration range, and the limits of detection (3σ) and quantification (10 σ) of the method are 1.2?×?10?8 mol L?1 and 4.01?×?10?8 mol L?1 5-HIAA, respectively. The recovery of 5-HIAA from urine samples spiked with 5-HIAA in three concentrations (1.4?×?10?6, 4.50?×?10?6 and 1.0?×?10?5 mol L?1) are within 63?±?3 %.
Figure
Cyclodextrin functional magnetic nanoparticles as sorbents for separation of 5-hydroxy-3-indole acetic acid and its fluorescence determination after released with methanol.  相似文献   

16.
Ionic liquids have attracted much attention in the analysis of a variety of species. The functional groups in ionic liquids can result in highly efficient separation and enrichment and, because of their typical lack of volatility, they are environmentally benign. We grafted imidazole cations onto the surface of chloromethyl polystyrene, denoted PS-CH2-[MIM]+Cl?, and this modified polymer was used to selectively extract the protein hemoglobin (Hb). The prepared extractant PS-CH2-[MIM]+Cl?, containing 2 mmol immobilized imidazole groups per gram polymer, was characterized by FT-IR, surface charge analysis, and elemental analysis. The adsorption efficiency was 91 %. The adsorption capacity of the PS-CH2-[MIM]+Cl? for Hb was 23.6 μg mg?1, and 80 % of the retained Hb could be readily recovered by use of 0.5 % (m/v) aqueous sodium dodecyl sulfate (SDS) solution as eluate. The activity of the eluted Hb was approximately 90 %. The prepared imidazole-containing solid phase polymer was used for direct adsorption of Hb without use of any other solid matrix as support of the ionic liquid. The material was used in practice to isolate Hb from human whole blood.
Figure
Coordination interaction between heme of hemoglobin and imidazolium-modified chloromethyl polystyrene.  相似文献   

17.
During their travel inside a traveling wave ion mobility cell (TW IMS), ions are susceptible to heating because of the presence of high intensity electric fields. Here, we report effective temperatures T eff,vib obtained at the injection and inside the mobility cell of a SYNAPT G2 HDMS spectrometer for different probe ions: benzylpyridinium ions and leucine enkephalin. Using standard parameter sets, we obtained a temperature of ~800 K at injection and 728?±?2 K into the IMS cell for p-methoxybenzylpyridinium. We found that T eff,vib inside the cell was dependent on the separation parameters and on the nature of the analyte. While the mean energy of the Boltzmann distributions increases with ion size, the corresponding temperature decreases because of increasing numbers of vibrational normal modes. We also investigated conformational rearrangements of 7+ ions of cytochrome c and reveal isomerization of the most compact structure, therefore highlighting the effects of weak heating on the gas-phase structure of biologically relevant ions.
Figure
?  相似文献   

18.
Feng Pan  Jie Mao  Qiang Chen  Pengbo Wang 《Mikrochimica acta》2013,180(15-16):1471-1477
Magnetic Fe3O4@SiO2 core shell nanoparticles containing diphenylcarbazide in the shell were utilized for solid phase extraction of Hg(II) from aqueous solutions. The Hg(II) loaded nanoparticles were then separated by applying an external magnetic field. Adsorbed Hg(II) was desorbed and its concentration determined with a rhodamine-based fluorescent probe. The calibration graph for Hg(II) is linear in the 60 nM to 7.0 μM concentration range, and the detection limit is at 23 nM. The method was applied, with satisfying results, to the determination of Hg(II) in industrial waste water.
Figure
Functional magnetic Fe3O4@SiO2 core shell nanoparticles were utilized for solid phase extraction of Hg(II) from aqueous solutions, and the extracted Hg(II) was determined by a rhodamine-based fluorescent probe RP with satisfying results.  相似文献   

19.
Mixed cationic and anionic surfactants were adsorbed on cadmium sulfide quantum dots (CdS QDs) capped with mercaptoacetic acid. The CdS QDs can be extracted into acetonitrile with 98 % efficiency in a single step. Phase separation only occurs at a molar ratio of 1:1.5 between cationic and anionic surfactants. The surfactant-adsorbed QDs in acetonitrile solution display stronger and more stable photoluminescence than in water solution. The method was applied for determination of silver(I) ion based on its luminescence enhancement of the QDs. Under the optimum conditions, the relative fluorescence intensity is linearly proportional to the concentration of silver(I) ion in the range between 50 pmol L?1and 4 μmol L?1, with a 20 pmol L?1 detection limit. The relative standard deviation was 1.93 % for 9 replicate measurements of a 0.2 μmol L?1 solution of Ag(I).
Figure
?  相似文献   

20.
An efficient method for analyzing illegal and medicinal drugs in whole blood using fully automated sample preparation and short ultra-high-performance liquid chromatography–tandem mass spectrometry (MS/MS) run time is presented. A selection of 31 drugs, including amphetamines, cocaine, opioids, and benzodiazepines, was used. In order to increase the efficiency of routine analysis, a robotic system based on automated liquid handling and capable of handling all unit operation for sample preparation was built on a Freedom Evo 200 platform with several add-ons from Tecan and third-party vendors. Solid-phase extraction was performed using Strata X-C plates. Extraction time for 96 samples was less than 3 h. Chromatography was performed using an ACQUITY UPLC system (Waters Corporation, Milford, USA). Analytes were separated on a 100 mm?×?2.1 mm, 1.7 μm Acquity UPLC CSH C18 column using a 6.5 min 0.1 % ammonia (25 %) in water/0.1 % ammonia (25 %) in methanol gradient and quantified by MS/MS (Waters Quattro Premier XE) in multiple-reaction monitoring mode. Full validation, including linearity, precision and trueness, matrix effect, ion suppression/enhancement of co-eluting analytes, recovery, and specificity, was performed. The method was employed successfully in the laboratory and used for routine analysis of forensic material. In combination with tetrahydrocannabinol analysis, the method covered 96 % of cases involving driving under the influence of drugs. The manual labor involved in preparing blood samples, solvents, etc., was reduced to a half an hour per batch. The automated sample preparation setup also minimized human exposure to hazardous materials, provided highly improved ergonomics, and eliminated manual pipetting.
Figure
Robotic setup for fully automated solid-phase extraction of whole blood  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号