首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
参量阵扬声器在管道噪声控制中的研究*   总被引:1,自引:2,他引:1       下载免费PDF全文
武帅兵  吴鸣  杨军 《应用声学》2013,32(6):439-445
为了解决管道有源噪声控制中声反馈造成的系统复杂度和计算量的增加,文中引入参量阵扬声器作为次级声源,利用其强指向性减小控制系统的声反馈。为了验证该方法可行性,本文分别在直管和L管中,对600 Hz单频噪声和频率范围为500 Hz~1000 Hz的窄带噪声进行了管道有源噪声控制,同时测量了参量阵扬声器的管内声场和降噪范围。结果表明,参量阵扬声器声反馈小,在没有声反馈补偿的条件下对单频噪声的降噪效果基本达到了声反馈补偿条件下普通扬声器的降噪效果,对窄带噪声的降噪效果稍差。此外,通过测量管道声场和降噪量,确定了参量阵扬声器的降噪区域为误差传感器下游整个管道,降噪面积为管道整个截面。这说明参量阵扬声器作为次级声源降低了系统的复杂度和算法的计算量,并取得了较好的降噪效果。  相似文献   

2.
The experimental validation of a generalised approach to the sensing of orthogonal contributors to the global error (acoustic potential energy) within a coupled structural–acoustic cavity is presented. The goal is the measurement and control of the global error without any knowledge of the structural dynamics of the noise source, based on an acoustic centric decomposition approach that is applicable to any noise source. Two sensing approaches are attempted, structural and acoustic sensing, to measure the global error within the coupled enclosure. Once estimates of the global error are obtained, minimisation with an adaptive feedforward controller is implemented. The level of achieved attenuation in the global error is compared. The achieved level of attenuation is also compared to the maximum level of attenuation of the global error that can be achieved based on the disturbance/secondary source arrangement. The maximum level of attenuation is evaluated from experimental data, rather than pure theoretical methods.  相似文献   

3.
Active noise control in ducts: some physical insights   总被引:1,自引:0,他引:1  
The mechanisms of active noise control in a duct are examined. Acoustical measurements are used to determine directly the acoustic power flow associated with both primary and secondary sources as a function of secondary to primary source strength ratio and volume velocity relative phase angles. A complete analytical model is also developed which allows calculation of individual source power flows and total downstream power flow as a function of source strengths and relative phase angles for finite size sources. It is evaluated for monopole and dual secondary source arrangements, but can be extended easily to any number of secondary sources. The model considers a finite size primary source in the plane of the duct cross section and evaluates the effect that the secondary sources have on the primary source power output. Measurements of individual source output powers and total downstream acoustic powers agree well with theoretical predictions. It is demonstrated that, for the monopole system, sound attenuation is achieved primarily by suppression of the primary source acoustic power output, with a little remaining power being absorbed by the secondary source. For the dual secondary source system, it is shown that the power is primarily absorbed by the secondary sources, but that, at phase and amplitude values slightly different to optimum, noise reduction is achieved by a combination of energy absorption and primary source power suppression. The analysis also demonstrates the dependence of the achievable noise reduction on secondary source size and location with respect to the primary source.  相似文献   

4.
In this paper, an adaptive fuzzy neural controller (AFNC) for a class of unknown chaotic systems is proposed. The proposed AFNC is comprised of a fuzzy neural controller and a robust controller. The fuzzy neural controller including a fuzzy neural network identifier (FNNI) is the principal controller. The FNNI is used for online estimation of the controlled system dynamics by tuning the parameters of fuzzy neural network (FNN). The Gaussian function, a specific example of radial basis function, is adopted here as a membership function. So, the tuning parameters include the weighting factors in the consequent part and the means and variances of the Gaussian membership functions in the antecedent part of fuzzy implications. To tune the parameters online, the back-propagation (BP) algorithm is developed. The robust controller is used to guarantee the stability and to control the performance of the closed-loop adaptive system, which is achieved always. Finally, simulation results show that the AFNC can achieve favourable tracking performances.  相似文献   

5.
Source identification of acoustic characteristics of in-duct fluid machinery is required for coping with the fluid-borne noise. By knowing the acoustic pressure and particle velocity field at the source plane in detail, the sound generation mechanism of a fluid machine can be understood. The identified spatial distribution of the strength of major radiators would be useful for the low noise design. Conventional methods for measuring the source in a wide duct have not been very helpful in investigating the source properties in detail because their spatial resolution is improper for the design purpose. In this work, an inverse method to estimate the source parameters with a high spatial resolution is studied. The theoretical formulation including the evanescent modes and near-field measurement data is given for a wide duct. After validating the proposed method to a duct excited by an acoustic driver, an experiment on a duct system driven by an air blower is conducted in the presence of flow. A convergence test for the evanescent modes is performed to find the necessary number of modes to regenerate the measured pressure field precisely. By using the converged modal amplitudes, very-close near-field pressure to the source is regenerated and compared with the measured pressure, and the maximum error was −16.3 dB. The source parameters are restored from the converged modal amplitudes. Then, the distribution of source parameters on the driver and the blower is clearly revealed with a high spatial resolution for kR<1.84 in which range only plane waves can propagate to far field in a duct. Measurement using a flush mounted sensor array is discussed, and the removal of pure radial modes in the modeling is suggested.  相似文献   

6.
The aim of this work is to show the energetic behavior when an active noise controller is applied in a one-dimensional waveguide, namely an ideal duct under the first critical frequency. In order to model the duct, a spectral element method, which is shown to be more practical for analyzing pipe networks than other commonly used analytical models, was used. The model used here consists of a duct with two sources, the primary source at one end of the duct, and the secondary source at the middle section. The error sensor was placed downstream from secondary source, and the other end of the duct was open with no flange. Three optimal control methods were applied: minimization of the potential energy density, minimization of the active intensity, and minimization of the total acoustic power radiated by the sources. It was observed that the three control methods achieved the same final result, and when the volume velocity of the secondary source was driven to the optimal volume velocity, neither the primary source nor the secondary source radiated any acoustic power. Furthermore, the controlled duct was equivalent to a duct opened-ended at the secondary source position with radiation impedance equal to zero.  相似文献   

7.
Intelligent active vibration control in an isolation platform   总被引:1,自引:0,他引:1  
This paper presents the study on the vibration attenuation in an isolated platform by combining multi-layer perception (MLP) neural network, radial basis function (RBF) neural network, cerebella model articulation controller (CMAC) neural network and fuzzy neural networks (FNN) with error back propagation algorithm to control voice coil actuator. Usually, the methods in past time to control vibration were mainly designed by using mathematical models, which must be nearly close to the actual plant models. As regards to these utilized control methods, the most important advantage of them are that they have capability of self tuning the parameters of controllers and could adapt the changes of the environments. The performance of attenuation and control effectiveness can be evaluated by placing the accelerator to measure the amplitude at the center of the isolated platform. The experimental results in this study show that the control methods as adopted could greatly attenuate the vibration of resonance and external disturbance in an isolation platform.  相似文献   

8.
建立了含次级源结构的充液直管有源消声系统数值模型,重点分析了声激励下次级源近场和管壁弹性对有源消声性能的影响。结果表明:次级源近场为非均匀声场,误差点位于该区域时部分频点控制效果较差甚至放大,而处于声场均匀区域时可使降噪量提高10 dB以上,增加误差点数量可使绝大多数频点的降噪量提高5 dB以上;管壁弹性使次级源与管壁间的耦合较强,非对称分布的次级源容易激起管壁振动,导致降噪谷值的出现,采用对称分布的次级源可显著提升控制效果;增加次级源数量能够提高系统的有源无源复合控制效果,但使得管内声场变得复杂,多次级源模型的有源消声效果随频率升高而有所降低。  相似文献   

9.
This study is reported of an optical approach to reduce the acoustic radiation from some uniformly square plates of different sizes. The content of this study includes the dynamical analysis of uniform plates, the theoretical consideration dealing with both the optical-error path and neural network control system, and the laboratory demonstration on the acoustic-radiation reduction from plates by using optical approach.Results of dynamical analysis on three different plates obviously reveal low odd-odd modes such as (1, 3) and (3, 3) mode must respond to the most acoustic radiation from plates. Laboratory demonstration claims that much more reduction of acoustic radiation from plates within greater frequency range can be reached when using an optical-error path to replace acoustic-error path. The corresponding experimental results obviously show that the greater control effectiveness on (3, 3) mode for smaller plate, single frequency, the greater effectiveness by 26 dB of acoustic radiation reduction for single point control than that for multi points control. Regarding to the double frequencies, the acoustic attenuation by 14.6 dB for compose of (3, 3) and (3, 4) in 60 cm plate are obtained.  相似文献   

10.
Active attenuation of noise in a duct generally requires either one or two rings of cancelling loudspeakers located around the duct perimeter. Consideration is given to the acoustic loading on the loudspeakers and it is shown that the use of a horn is likely to create more problems that it solves. Direct radiator operation, with the drive units attached directly to the duct walls, is preferable. The single ring (monopole) system reflects the noise giving rise to upstream standing waves, meaning that the loudspeakers and amplifiers must be able to handle correspondingly larger signals. The double ring (dipole) system absorbs the noise and is more efficient than the monopole system. The dipole system can be made still more efficient over a narrow band of frequencies by tuning both the loudspeakers and the spacing between them.  相似文献   

11.
An active window system to reduce the exterior noise sources, such as traffic noise and construction noise which enter rooms through open windows used for natural ventilation is proposed. The proposed system uses a feedforward control method for active noise control so as not to place the sensors and control sources inside the interior space of the building. For global noise reduction throughout the interior room, the control gains for feedforward control are calculated to minimize the total acoustic power of the new source, which is combined with the noise source corresponding to the open window and control sources on the window frame. The performance of the proposed system for directional exterior noise is confirmed with a scale-model experiment. The experimental results show that the proposed system can achieve a noise reduction of up to 10 dB for the entire room of the scale model regardless of the direction of the incident wave.  相似文献   

12.
13.
The potential of a piezoelectric, double-amplifier active-skin with structural acoustic sensing (SAS) is demonstrated for the reduction of broadband acoustic radiation from a clamped, aluminum plate. The active-skin is a continuous covering of the vibrating portions of the plate with active, independently controllable piezoelectric, double-amplifier elements and is designed to affect control by altering the continuous structural radiation impedance rather than structural vibration. In simulation, acoustic models are sought for the primary and secondary sources that incorporate finite element methods. Simulation indicates that a total radiated power attenuation in excess of 10 dB may be achieved between 250 and 750 Hz with microphone error sensing, while under SAS the radiated power is reduced by nearly 8 dB in the same frequency range. In experiment, the adaptive feed forward filtered-x LMS (least mean square) algorithm, implemented on a Texas Instruments C40 DSP, was used in conjunction with the 6I6O control system. With microphone error sensing, 11.8-dB attenuation was achieved in the overall radiated power between 175 and 600 Hz, while inclusion of SAS resulted in a 7.3-dB overall power reduction in this frequency band.  相似文献   

14.
This paper proposes an active partition that can be placed between a snorer and a non-snorer on a bed to reduce the snoring noise around the non-snorer ears by integrating a rigid finite size passive partition with a two channel active noise control system. The noise reduction performance of the passive partition on a bed with a headboard is studied first, where the effects of the height and the width of the partition are discussed. Due to the limited partition size, the attenuation for the low-frequency diffracted noise is not sufficient, so two loudspeakers are proposed to be installed on the partition as the secondary sources to increase the overall noise attenuation. Both numerical simulations and experiments are carried out to demonstrate the feasibility of the proposed integrated snoring noise control system, and the results show that the proposed active partition can achieve over 10 dB noise attenuation at non-snorer ears in the 1/3 octave bands from 80 to 1000 Hz.  相似文献   

15.
The active control of radiation from large structures is a difficult, though important practical problem. The major reason for the difficulty is the ‘system’ size, as a large number of sensors and actuators are required for successful implementation, thus making it hard to design a robust, efficient system that integrates all sensors and actuators. This work examines the active attenuation of the global error, sound power, from the point of view of two sensing/control strategies that seek to be generalised; thus are applicable to a wide range of applications and are independent of knowledge of structural dynamics. In each approach the idea is that the required hardware can simply be attached, turned on, and immediately being to attenuate global noise. The two strategies are compared based on the level of attenuation of the global error sound power, the attenuation per total control force, and attenuation per actuator (in a structural-acoustic situation). The first strategy is the collocated-decentralised approach, which is built on measuring and controlling local vibration in an attempt to influence the global acoustic error. An alternative approach, termed the hybrid approach is firstly developed. The approach is termed ‘hybrid’ because it is a mix between a fully ‘centralised’ and ‘decentralised’ approach; but still measuring and controlling the global acoustic error directly. The attenuation of sound power is compared for both strategies on two structural sources; using 16 identically placed velocity sensors and 16 secondary point sources, in simulation in an attempt to suggest efficient sensing and control approaches for the global control of sound radiation from large structural sources.  相似文献   

16.
17.
Functional magnetic resonance imaging (fMRI) provides a noninvasive tool for observing correlates of neural activity in the brain while a subject listens to sound. However, intense acoustic noise is generated in the process of capturing MR images. This noise stimulates the auditory nervous system, limiting the dynamic range available for displaying stimulus-driven activity. The noise is potentially damaging to hearing and is distracting for the subject. In an active noise control (ANC) system, a reference sample of a noise is processed to form a sound which adds destructively with the noise at the listener's ear. We describe an implementation of ANC in the electromagnetically hostile and physically compact MRI scanning environment. First, a prototype system was evaluated psychoacoustically in the laboratory, using the electrical drive to a noise-generating loudspeaker as the reference. This system produced 10-20 dB of subjective noise-reduction between 250 Hz and 1 kHz, and smaller amounts at higher frequencies. The system was modified to operate in a real MR scanner where the reference was obtained by recording the acoustic scanner noise. Objective reduction by 30-40 dB of the most intense component in scanner noises was realized between 500 Hz and 3500 Hz, and subjective reduction of 12 dB and 5 dB in tests at frequencies of 600 Hz and at 1.9 kHz, respectively. Although the benefit of ANC is limited by transmission paths to the cochlea other than air-conduction routes from the auditory meatus, ANC achieves worthwhile attenuation even in the frequency range of maximum bone conduction (1.5-2 kHz). ANC should, therefore, be generally useful during auditory fMRI.  相似文献   

18.
19.
Plasma actuators were used in this work to control flow-induced broadband noise radiated from a bluff body. The model consists of a cylinder and a component (torque link) that is installed on the lee side of the cylinder. The objective is to reduce the broadband noise mainly generated through the impingement of the cylinder wake on the torque link. The flow-structure interactions between the cylinder wake and the torque link are reduced by manipulating the cylinder wake with the externally imposed body force from the plasma actuators, which lead to the attenuation of the broadband noise. The control performance with the plasma actuators is studied in an anechoic chamber facility by examining far-field sound level and near-field acoustic source changes. At a free stream speed of 30 m/s, corresponding to the Reynolds number of 2.1×105, far-field measurements suggested that a reduction of up to 3.2 dB in overall sound pressure level. The near-field beamforming results also show approximately 3 dB reduction in the interested frequency ranges. The physical mechanisms related to broadband noise control were also discussed. This work suggests that plasma actuators offer the potential for solving flow-induced noise control problem at broadband frequencies.  相似文献   

20.
Active noise control has been applied to a variety of systems in order to improve performance without the increases in size and weight that would otherwise be required by traditional passive noise control treatments. This paper investigates the application of an active noise control system to the control of generator noise in the master cabin of a luxury yacht. A multichannel, multi-tonal active noise control system employing loudspeakers and microphones in the master cabin of the yacht is investigated. It is shown that, due to the high number of engine orders produced by the generator, in order to achieve significantly perceptible levels of noise attenuation it is necessary to control at least 7 individual orders. A controller is investigated which targets 19 engine orders and it is shown to achieve in excess of 5 dB broadband attenuation, whilst achieving up to 23 dB attenuation in individual orders. This corresponds to a 23% reduction in the Zwicker loudness.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号