首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 399 毫秒
1.
DNA analysis of degraded samples and low-copy number DNA derived from skeletal remains, one of the most challenging forensic tasks, is common in disaster victim identification and genetic analysis of historical materials. Massively parallel sequencing (MPS) is a useful technique for STR analysis that enables the sequencing of smaller amplicons compared with conventional capillary electrophoresis (CE), which is valuable for the analysis of degraded DNA. In this study, 92 samples of human skeletal remains (70+ years postmortem) were tested using an in-house MPS-STR system designed for the analysis of degraded DNA. Multiple intrinsic factors of DNA from skeletal remains that affect STR typing were assessed. The recovery of STR alleles was influenced more by DNA input amount for amplification rather than DNA degradation, which may be attributed from the high quantity and quality of libraries prepared for MPS run. In addition, the higher success rate of STR typing was achieved using the MPS-STR system compared with a commercial CE-STR system by providing smaller sized fragments for amplification. The results can provide constructive information for the analysis of degraded sample, and this MPS-STR system will contribute in forensic application with regard to skeletal remain sample investigation.  相似文献   

2.
Massively parallel sequencing (MPS) technologies have the ability to reveal sequence variations within STR alleles as well as their nominal allele lengths, which have traditionally been detected by CE instruments. Recently, Thermo Fisher Scientific has updated the MPS-STR panel, named the Precision ID GlobalFiler next-generation sequencing (NGS) STR Panel version 2, with primers redesigned to add two pentanucleotide tandem repeat loci and profile interpretation supported by the Converge software. Using the Ion Chef System, the Ion S5XL System, and the Converge software, genetic variations were characterized within STR repeat and flanking regions of 30 autosomal STR markers in 115 unrelated individuals from two Chinese population groups (58 Tibetans and 57 Hans). Nineteen STRs demonstrated a relative increase in diversity with the variant sequence alleles compared with those of traditional nominal length alleles. In total, 390 alleles were identified by their sequences compared with 258 alleles that were identified by length. Of these 92 sequence variants found within the STR repeat regions, 40 variants were located in STR flanking regions. Additionally, the agreement of the results with CE data was evaluated, as was the ability of this new MPS panel to analyze case-type (11 samples) and artificially degraded samples (seven samples in triplicate). The results generated from this study illustrate that extensive sequence variation exists in commonly used STR markers in the selected population samples and indicate that this NGS STR panel has the potential to be used as an effective tool for human forensics.  相似文献   

3.
Semi‐nested PCR with allele‐specific (AS) primers and sequencing of mitochondrial DNA (mtDNA) were performed to analyze and interpret DNA mixtures, especially when biological materials were degraded or contained a limited amount of DNA. SNP‐STR markers were available to identify the minor DNA component using AS‐PCR; moreover, SNPs in mtDNA could be used when the degraded or limited amounts of DNA mixtures were not successful with SNP‐STR markers. Five pairs of allele‐specific primers were designed based on three SNPs (G15043A, T16362C, and T16519C). The sequence of mtDNA control region of minor components was obtained using AS‐PCR and sequencing. Sequences of the amplification fragments were aligned and compared with the sequences of known suspects or databases. When this assay was used with the T16362C and T16519C SNPs, we found it to be highly sensitive for detecting small amounts of DNA (~30 pg) and analyzing DNA mixtures of two contributors, even at an approximately 1‰ ratio of minor and major components. An exception was tests based on the SNP G15043A, which required approximately 300 pg of a 1% DNA mixture. In simulated three contributor DNA mixtures (at rate of 1:1:1), control region fragments from each contributor were detected and interpreted. AS‐PCR combined with semi‐nested PCR was successfully used to identify the mtDNA control region of each contributor, providing biological evidence for excluding suspects in forensic cases, especially when biological materials were degraded or had a limited amount of DNA.  相似文献   

4.
In this paper we compare the effects of three representative PCR inhibitors using quantitative PCR (qPCR) and multiplex STR amplification in order to determine the effect of inhibitor concentration on allele dropout and to develop better ways to interpret forensic DNA data. We have used humic acid, collagen and calcium phosphate at different concentrations to evaluate the profiles of alleles inhibited in these amplifications. These data were correlated with previously obtained results from quantitative PCR including melt curve effects, efficiency changes and cycle threshold (Ct) values. Overall, the data show that there are two competing processes that result from PCR inhibition. The first process is a general loss of larger alleles. This appears to occur with all inhibitors. The second process is more sequence specific and occurs when the inhibitor binds DNA, altering the cycle threshold and the melt curve. This sequence-specific inhibition results in patterns of allele loss that occur in addition to the overall loss of larger alleles. The data demonstrate the applicability of utilizing real-time PCR results to predict the presence of certain types of PCR inhibition in STR analysis.  相似文献   

5.
Whole-genome DNA amplification (WGA) is a promising method that generates large amounts of DNA from samples of limited quantity. We investigated the accuracy of a multiplex PCR approach to WGA over STR loci. The amplification bias within a locus and over all analyzed loci was investigated in relation to the amount of template in the WGA reaction, the specific STR locus, and allele length. We observed reproducible error-free STR profiles with 10 ng down to 1 ng of DNA template. The amplification deviation at a locus and between loci was within the intra-method reproducibility. WGA is the method of choice for amplifying nanogram amounts of genomic DNA for different applications. We detected unbalanced STR amplifications at one locus and between loci, allelic drop-outs, and additional alleles after WGA of low-copy-number DNA. We found that the high number of drop-outs and drop-ins could be eradicated using pooled DNA from separate WGA reactions even with as little as 100 pg of starting template. Nevertheless, the quality of the results was still not sufficient for use in routine chimerism analysis of limited specific cell populations after allogeneic stem cell transplantation.  相似文献   

6.
The recent introduction of polymerase chain reaction (PCR)-massively parallel sequencing (MPS) technologies in forensics has changed the approach to allelic short tandem repeat (STR) typing because sequencing cloned PCR fragments enables alleles with identical molecular weights to be distinguished based on their nucleotide sequences. Therefore, because PCR fidelity mainly depends on template integrity, new technical issues could arise in the interpretation of the results obtained from the degraded samples. In this work, a set of DNA samples degraded in vitro was used to investigate whether PCR-MPS could generate “isometric drop-ins” (IDIs; i.e., molecular products having the same length as the original allele but with a different nucleotide sequence within the repeated units). The Precision ID GlobalFiler NGS STR panel kit was used to analyze 0.5 and 1 ng of mock samples in duplicate tests (for a total of 16 PCR-MPS analyses). As expected, several well-known PCR artifacts (such as allelic dropout, stutters above the threshold) were scored; 95 IDIs with an average occurrence of 5.9 IDIs per test (min: 1, max: 11) were scored as well. In total, IDIs represented one of the most frequent artifacts. The coverage of these IDIs reached up to 981 reads (median: 239 reads), and the ratios with the coverage of the original allele ranged from 0.069 to 7.285 (median: 0.221). In addition, approximately 5.2% of the IDIs showed coverage higher than that of the original allele. Molecular analysis of these artifacts showed that they were generated in 96.8% of cases through a single nucleotide change event, with the C > T transition being the most frequent (85.7%). Thus, in a forensic evaluation of evidence, IDIs may represent an actual issue, particularly when DNA mixtures need to be interpreted because they could mislead the operator regarding the number of contributors. Overall, the molecular features of the IDIs described in this work, as well as the performance of duplicate tests, may be useful tools for managing this new class of artifacts otherwise not detected by capillary electrophoresis technology.  相似文献   

7.
For over 10 years, quantitative PCR (qPCR) for DNA quantitation has been reported in forensics. However, assays have not been described for small qPCR platforms. Thus, technological advancement is not always implemented in small forensic genetics laboratories. A duplex qPCR assay is reported, using a StepOne instrument and targeting a short and a long human DNA region. This study was performed according to international validation guidelines, including sensitivity, repeatability, reproducibility, precision, accuracy, contamination assessment, known and case-type samples, and degradation studies. Characterization of the genetic markers, species specificity, and population studies had already been conducted. Moreover, case-type samples were quantified, amplified using commercial kits and the number of alleles detected was recorded. Sensitivity was shown to be 10 pg/µL. Standard curve replicates demonstrated the assay is accurate, precise, as well as fairly repeatable and reproducible. The NGM Detect kit was shown to yield higher peaks than Identifiler Plus and NGM Select for degraded samples. Moreover, quality sensors were always present and proved useful. The quantification values of the large target showed a correlation with the number of alleles detected in the STR profiles for known and casework samples. The degradation index was shown to be informative, with a value of 10 or higher indicating dropout. It is suggested that after quantitation, samples with low or degraded DNA be amplified using newer amplification kits containing quality sensors to confirm that the low-quality profile was not affected by inhibition.  相似文献   

8.
An allele‐specific voltammetric genoassay for the detection of allele‐specific toll‐like receptor‐2 gene arg753gln polymorphism (TLR‐2) from polymerase chain reaction (PCR) amplified real samples was described in this study. Meldola blue (MDB), an intercalator molecule, was used as hybridization label. The wild‐type and mutant type oligonucleotide probes were immobilized onto disposable graphite electrode surfaces by covalent attachment method. The extent of hybridization between probe and target sequences was determined by using differential pulse voltammetry (DPV). As a result of the interaction between MDB and DNA at electrode surface, the MDB signal observed from probe sequence before hybridization and after hybridization with MM sequence is lower than that observed after hybridization with complementary sequence. The differences between the MDB reduction peaks obtained from probe modified, hybrid modified and MM modified electrode were used to detect TLR‐2 from PCR amplified real samples. The discrimination of homozygous and heterozygous alleles was also established by comparing the peak currents of MDB reduction signals. Numerous factors affecting the target hybridization and indicator binding reactions are optimized to maximize the sensitivity.  相似文献   

9.
DNA profiling of short tandem repeats (STR) has been successfully used for the identification of individuals in forensic samples, accidents and natural disasters. However, STR profiling of DNA isolated from old crime scenes and damaged biological samples is difficult due to DNA degradation and fragmentation. Here, we show that pre‐amplification of STR loci using biotinylated primers for the STR loci is an efficient strategy to obtain STR profiling results from fragmented forensic samples. Analysis of STR loci with longer amplicon sizes is generally hampered, since these relatively long loci are vulnerable to DNA fragmentation. This problem was overcome by using reduced or increased primer concentrations for loci with shorter or longer amplicon sizes, respectively, in our pre‐amplification strategy. In addition, pre‐amplification of STR loci into two groups of short or long amplicon size increases the efficiency of STR profiling from highly fragmented forensic DNA samples. Therefore, differential pre‐amplification of STR loci is an effective way to obtain DNA profiling results from fragmented forensic samples.  相似文献   

10.
Short tandem repeat (STR) loci, widely used as genetic markers in disease diagnostic studies and human identity applications, are traditionally genotyped through comparison of allele sizes to a sequenced allelic ladder. Allelic ladders permit a floating bin allele calling method to be utilized, which enables reliable allele calling across laboratories, instrument platforms, and electrophoretic conditions. Precise sizing methods for STR allele calling involving fixed bins can also be used when a high degree of precision has been demonstrated within an instrument platform and a set of electrophoretic conditions. An alternative method for reliable genotyping of STR markers, locus-specific brackets (LSBs), is introduced here. LSBs are artificial alleles created through molecular biology manipulations to be shorter or longer than alleles commonly seen in populations under investigation. The size and repeat number of measured alleles are interpolated between the two LSB products that are mixed with the polymerase chain reaction-amplified STR alleles. The advantages and limitations of the LSB approach are described along with a concordance study between the LSB typing approach and other STR typing methods. Complete agreement was observed with 162 samples studied at 5 Y-chromosome loci.  相似文献   

11.
A fluorescence energy transfer (ET) dye-labeled STR typing system (ET 16-plex) is developed for the markers used in the commercial STR typing kit PowerPlex 16, and its performance assessed using a 96-lane microfabricated capillary array electrophoresis (muCAE) system. The ET 16-plex amplicons displayed 1.6-9-fold higher fluorescence intensities compared to those produced using the single-dye (SD)-labeled multiplex kits. The ET multiplex delivered full STR profiles from 62.5 pg of DNA; half the input required for the SD kits while maintaining a similar heterozygote allele balance. This increased sensitivity should improve typing of poor-quality DNA samples by making minor or imbalanced alleles more readily detectable at the low copy number (LCN) threshold. The ET 16-plex also generated complete profiles with only 28 PCR cycles; this capability should improve LCN typing by reducing the amplification time and drop-in allele incidence. To confirm the practical advantages of ET-labeled primers, six previously problematic casework samples were tested and only the ET 16-plex kit was able to capture additional allele data. The successful development and demonstration of ET primers for higher sensitivity STR typing offers a simple solution to improving current commercial multiplex typing capability. The superior spectral properties and universal compatibility with any primer sequence provided by ET cassettes will make future multiplex construction more facile and straightforward. The pairing of ET cassette technology with the muCAE system illustrates not only an enhanced STR typing platform, but a significant step toward a higher-efficiency forensic laboratory enabled by better chemistry and microfluidics.  相似文献   

12.
We report a new approach for electrochemical quantification of single-nucleotide polymorphisms (SNPs) using nanoparticle probes. The principle is based on DNA polymerase I (Klenow fragment)-induced coupling of the nucleotide-modified nanoparticle probe to the mutant sites of duplex DNA under the Watson-Crick base pairing rule. After liquid hybridization events occurred among biotinylated DNA probes, mutant DNA, and complementary DNA, the resulting duplex DNA helixes were captured to the surface of magnetic beads through a biotin-avidin affinity reaction and magnetic separation. A cadmium phosphate-loaded apoferritin nanoparticle probe, which is modified with nucleotides and is complementary to the mutant site, is coupled to the mutant sites of the formed duplex DNA in the presence of DNA polymerase. Subsequent electrochemical stripping analysis of the cadmium component of coupled nanoparticle probes provides a means to quantify the concentration of mutant DNA. The method is sensitive enough to detect 21.5 attomol of mutant DNA, which will enable the quantitative analysis of nucleic acid without polymerase chain reaction preamplification. The approach was challenged with constructed samples containing mutant and complementary DNA. The results indicated that it was possible to accurately determine SNPs with frequencies as low 0.01. The proposed approach has a great potential for realizing an accurate, sensitive, rapid, and low-cost method of SNP detection.  相似文献   

13.
Amplification/hybridization‐based genetic analyses using primers containing locked nucleic acids (LNAs) present many benefits. Here, we developed a novel design for universal fluorescent PCR using LNAs. Universal fluorescent PCR generates intermediate nonlabeled fragments and final fluorescent fragments in a two‐step amplification process that uses locus‐specific primers with universal tails and universal fluorescent primers. In this study, a few standard nucleotides were replaced with LNAs only in the fluorescent universal primers. The sequence of the fluorescent universal primer significantly affected the amplification efficiency. For primers with three LNAs, the fluorescent primers with stable M13(‐47) sequences provided the most efficient signal (approximately tenfold higher than the primers with M13(‐21) sequences at lower Tm values). Moreover, AT‐rich LNA substitutions in the fluorescent primers produced much lower amplification efficiencies than GC‐rich substitutions. GC‐rich LNAs produced greater differences in Tm values among primers, and resulted in the preferential production of fluorescently labeled amplicons. The specificity and sensitivity of LNA‐containing fluorescent primers were assessed by genotyping eight STRs in Japanese individuals, and full STR profiles could be generated using as little as 0.25 ng of genomic DNA. The method permitted clear discrimination of alleles and represents sensitive STR genotyping at a reduced cost.  相似文献   

14.
In the present study, we investigated the properties of PNA and LNA capture probes in the development of an electrochemical hybridization assay. Streptavidin-coated paramagnetic micro-beads were used as a solid phase to immobilize biotinylated DNA, PNA and LNA capture probes, respectively. The target sequence was then recognized via hybridization with the capture probe. After labeling the biotinylated hybrid with a streptavidin–enzyme conjugate, the electrochemical detection of the enzymatic product was performed onto the surface of a disposable electrode. The assay was applied to the analytical detection of biotinylated DNA as well as RNA sequences. Detection limits, calculated considering the slope of the linear portion of the calibration curve in the range 0–2 nM were found to be 152, 118 and 91 pM, coupled with a reproducibility of the analysis equal to 5, 9 and 6%, calculated as RSD%, for DNA, PNA and LNA probes respectively, using the DNA target. In the case of the RNA target, the detection limits were found to be 51, 60 and 78 pM for DNA, PNA and LNA probes respectively.  相似文献   

15.
A label-free and non-enzymatic amplification fluorescent method for detection of DNA has been developed by using hybridization chain reaction (HCR) and dsDNA-templated copper nanoparticles (CuNPs). First, the biotinylated capture DNA probes were immobilized on the streptavidin-modified beads through the interaction of biotin and streptavidin. Then, target DNA hybridized with the capture DNA probes, which formed a hybridized DNA with sticky end. The sticky end triggered the HCR process and formation of dsDNA polymers while two hairpin probes coexisted. Subsequently, the dsDNA polymers were employed as template for synthesis of CuNPs with excellent fluorescent properties, which provided a label-free, non-enzymatic signal response. Meanwhile, the fluorescence sensing depended on the target DNA triggered HCR, which render this method a high selectivity against single-base mismatch sequences. The concept and methodology developed in this work show great promise in the quantitative detection of DNA in biological and medical applications.  相似文献   

16.
《Electrophoresis》2017,38(13-14):1771-1779
Telogen hairs presented in the crime scene are commonly encountered as trace evidence. However, short tandem repeat (STR) profiling of the hairs currently have low and limited use due to poor success rate. To increase the success rate of STR profiling of telogen hairs, we developed a rapid and cost‐effective method to estimate the number of nuclei in the hair roots. Five cationic dyes, Methyl green (MG), Harris hematoxylin (HH), Methylene blue (MB), Toluidine blue (TB), and Safranin O (SO) were evaluated in this study. We conducted a screening test based on microscopy and the percentage of loss with nuclear DNA, in order to select the best dye. MG was selected based on its specific nuclei staining and low adverse effect on the hair‐associated nuclear DNA. We examined 330 scalp and 100 pubic telogen hairs with MG. Stained hairs were classified into five groups and analyzed by STR. The fast staining method revealed 70% (head hair) and 33.4% (pubic hair) of full (30 alleles) and high partial (18–29 alleles) STR profiling proportion from the lowest nuclei count group (one to ten nuclei). The results of this study demonstrated a rapid, specific, nondestructive, and high yield DNA profiling method applicable for screening telogen hairs.  相似文献   

17.
Base-calling precision of short tandem repeat (STR) allelic bands on dynamic slab-gel electrophoresis systems was evaluated. Data was collected from over 6000 population database allele peaks generated from 468 population database samples amplified with the AmpF/STR Profiler Plus (PP) kit and electrophoresed on ABD 377 DNA sequencers. Precision was measured by way of standard deviations and was shown to be essentially the same, whether using fixed or floating bin genotyping. However, the allelic ladders have proven more sensitive to electrophoretic variations than database samples, which have caused some floating bins of D18S51 to shift on occasion. This observation prompted the investigation of polyacrylamide gel formulations in order to stabilize allelic ladder migration. The results demonstrate that, although alleles comprised in allelic ladders and questioned samples run on the same gel should migrate in an identical manner, this premise needs to be verified for any given electrophoresis platform and gel formulation. We show that the compilation of base-calling data is a very informative and useful tool for assessing the performance stability of dynamic gel electrophoresis systems, stability on which depends genotyping result quality.  相似文献   

18.
《Electrophoresis》2017,38(7):1016-1021
A Y‐STR multiplex system has been developed with the purpose of complementing the widely used 17 Y‐STR haplotyping (AmpFlSTR Y Filer® PCR Amplification kit) routinely employed in forensic and population genetic studies. This new multiplex system includes six additional STR loci (DYS576, DYS481, DYS549, DYS533, DYS570, and DYS643) to reach the 23 Y‐STR of the PowerPlex® Y23 System. In addition, this kit includes the DYS456 and DYS385 loci for traceability purposes. Male samples from 625 individuals from ten worldwide populations were genotyped, including three sample sets from populations previously published with the 17 Y‐STR system to expand their current data. Validation studies demonstrated good performance of the panel set in terms of concordance, sensitivity, and stability in the presence of inhibitors and artificially degraded DNA. The results obtained for haplotype diversity and discrimination capacity with this multiplex system were considerably high, providing further evidences of the suitability of this novel Y‐STR system for forensic purposes. Thus, the use of this multiplex for samples previously genotyped with 17 Y‐STRs will be an efficient and low‐cost alternative to complete the set of 23 Y‐STRs and improve allele databases for population and forensic purposes.  相似文献   

19.
P Gill  P Koumi  H Allen 《Electrophoresis》2001,22(13):2670-2678
A 96-capillary array gel electrophoresis Applied Biosystems 3700 instrument has been used to analyse AMPF/STR SGM Plus short tandem repeat (STR) loci for forensic applications. This multiplex consists of ten STR loci plus the Amelogenin locus and currently forms the basis of the UK National DNA database that currently holds more than 1 million profiles. Of particular interest is the accuracy of allele designation that is determined by comparison with standard control allelic ladder markers. Some loci have higher standard deviations than others. In particular the high-molecular-weight HUMFIBRA alleles have high standard deviations of the order of 0.15 and it is these alleles that are most likely to be misdesignated. However, this risk is minimised by the analysis of at least five different allelic ladders across the array to estimate the mean size of each allele. In conjunction with this, a series of guidelines that can be programmed into expert systems are used to minimise risks of misdesignation. The efficacy of the procedures utilised are tested by computer simulation and demonstrated to be robust.  相似文献   

20.
A DNA sample was partially degraded by scalar heat-acid treatments to study the extent of apurinic-apyrimidinic (A-P) lesions produced along the molecule. A CE-UV method allowed us to measure the rate of depurination at pH 5.0 and 70°C which was calculated to be 5.41×10(-6) s(-1) for adenine and 6.27×10(-6) s(-1) for guanine. CE identified depurination on treated samples when it occurred with a loss of >4% of the basic moieties. The molecular features of the A-P enriched samples were investigated by using molecular assays (agarose gel electrophoresis, UV spectrophotometry and quantitative PCR) and the consistency of the results of the STR typing were compared with the degree of depurination of the PCR template. The treated DNA samples showed molecular features such as fragmentation, altered OD(260) /OD(280) ratios and decreased ability of the quantitative PCR to synthesise the human target, related to the severity of depurination. A satisfactory correlation between the degree of damage and the amount of residual PCR-sensitive target sequences was also demonstrated (r(2) =0.9717). The conventional and mini-STR typing of the samples showed that the genetic outcome was influenced by a depurination damage that exceeded 4% when locus drop-outs and artefactual PCR results were evident. As the success of STR typing depends on the integrity of the DNA recovered from the samples, the CE-UV, physical and molecular assays described here are proposed as a set of useful methods in the analysis of certain forensic and clinical samples, for a critical evaluation of the outcome of the genetic testing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号