首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A liquid chromatographic method is described for separating and determining vinblastine, vincristine and vindesine in plasma and urine. The drugs are extracted from the biological material using an ion-pair extraction, with sodium octylsulphate as counter-ion at pH 3. The extracts are injected on a reversed-phase system with a cyano column as stationary phase and a mobile phase composed of acetonitrile-phosphate buffer, pH 3 (65:35, vol. %). Stability studies are carried out for stock solutions of the drugs in water at different temperatures and pH values. The stability of these compounds in plasma is also investigated in the presence of an antioxidant. The method is applied to determine drug levels of vindesine and vinblastine in preliminary pharmacokinetic studies, using vincristine as the internal standard.  相似文献   

3.
4.
5.
6.
A high-performance liquid chromatographic assay for determination of cefonicid concentrations in human plasma and urine samples has been developed using cefazolin as an internal standard. For the analysis of plasma samples two calibration curves were utilized covering the cefonicid concentration ranges of 0.05-1.0 microgram/ml and 1.0-50.0 micrograms/ml, respectively. Coefficients of variation of 7.4% or less were obtained for cefonicid concentrations of 0.05-50.0 micrograms/ml. Mean bias was +6.0% at 0.05 micrograms/ml cefonicid and between -2.1% and +1.6% for 1.0-50.0 micrograms/ml cefonicid. Plasma samples containing 30 ng/ml cefonicid could be well distinguished from blank plasma samples. Urine samples were analysed by using a calibration curve for cefonicid concentrations between 1.0 and 50.0 micrograms/ml. ranged from 8.6% at a cefonicid concentration of 1.0 microgram/ml to 0.5% at 50.0 micrograms/ml with a mean bias between -3.0% and +0.3%.  相似文献   

7.
A selective and sensitive high-performance liquid chromatographic method for determination of intact glibenclamide in human plasma or urine has been developed. With glibornuride as internal standard, acid-buffered plasma or urine was extracted with benzene. The organic layer was evaporated and the residue was dissolved in equilibrated mobile phase (acetonitrile-phosphate buffer 0.01 M pH 3.5, 50:50). An aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column, and quantitation was achieved by monitoring the ultraviolet absorbance at 225 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents could be noted. The utility of the method was demonstrated by analysing glibenclamide in samples from diabetic subjects on therapeutic doses of the drug.  相似文献   

8.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) and chromatographed on a column packed with Spherosil XOA 600 (5 micrometers) using a 7:3 (v/v) mixture of diisopropyl either--isooctane (1:1, v/v + 0.2% triethylamine and diisopropyl ether--methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. less than 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

9.
A sensitive and selective high-performance liquid chromatographic method for determination of intact glipizide in human plasma or urine has been developed. The plasma and urine samples were acid-buffered, before tolbutamide was added as internal standard. The samples were extracted with benzene, and the organic layer was evaporated to dryness. The residue was dissolved in equilibrated mobile phase (acetonitrile-0.01 M phosphate buffer pH 3.5, 35:65), and an aliquot of 20 microliters was chromatographed on a Spherisorb ODS reversed-phase column. Quantitation was achieved by monitoring the ultraviolet absorbance at 275 nm. The response was linear (0-1000 ng/ml) and the detection limit was 5-10 ng/ml in plasma or urine. The within-assay variation was less than or equal to 10%. No interferences from metabolites or endogenous constituents were observed. The utility of the assay was demonstrated by determining glipizide in samples from a diabetic subject receiving a therapeutic dose of 5 mg of the drug.  相似文献   

10.
A high-performance liquid chromatographic method for the measurement of isepamicin, a new aminoglycoside, in plasma, urine and dialysate is reported. The assay utilizes a simple extraction of isepamicin in plasma using commercially available Cyano solid-phase cartridges and dilution of urine and dialysate samples. The separation is performed on a Hypersil C18 column (15 cm X 4.6 mm I.D., 5 microns particle size) and utilizes a mobile phase consisting of 10% methanol and 90% buffer solution containing 0.01 M sodium hexanesulfonate, 0.1 M sodium sulfate and 17 mM acetic acid. The flow-rate is 1.1 ml/min. Dibekacin is used as the internal standard. Isepamicin is derivatized post-column with o-phthalaldehyde for spectrofluorometric detection. The method can also be used for the measurement of other aminoglycosides, i.e. tobramycin, kanamycin, netilmicin and gentamicin. The assay is fast, accurate and has a quantitation limit of 100 ng/ml isepamicin in plasma and 50 ng/ml in urine and dialysate.  相似文献   

11.
12.
A simple, rapid and sensitive method for the determination of iothalamic acid (IA) in both plasma and urine is reported. After extraction with ethyl acetate, IA was determined by strong anion-exchange high-performance liquid chromatography with ultraviolet detection at 254 nm. The lower limit of detection was 0.5 micrograms/ml. The average recovery was 73 and 57% from plasma and urine, respectively. Linearity was found over the investigated concentration range (up to 500 micrograms/ml for plasma and up to 10.0 mg/ml for urine). The reproducibility of the technique was good (coefficient of variation less than 6%) as was the precision and accuracy (coefficient of variation less than 2.5%). No interference from endogenous substances or any of the common drugs tested was found.  相似文献   

13.
Azanidazole can be measured in plasma and urine by reversed-phase high-performance liquid chromatography employing UV detection. Peak mean plasma concentrations of azanidazole, of 267 ng/ml, occurred at 1.5 h after single oral doses to human subjects, and declined with a half-life of 0.8 h. Less than 0.5% of the dose was excreted in the urine as unchanged drug. Metabolites of azanidazole were also detected by the procedures used.  相似文献   

14.
15.
16.
A reversed-phase high-performance liquid chromatography assay for mangiferin in rat plasma and urine was developed. Rutin was employed as an internal standard. The mobile phase consisted of acetonitrile-water (16:84, v/v) containing 3% acetic acid at a flow rate of 1 mL/min. Detection was at 257 and 365 nm for mangiferin in plasma and urine, respectively. The limit of quantitation (LOQ) of mangiferin was 0.6 microg/mL in plasma, and 0.48 microg/mL in urine. The standard curve was linear from 0.6 to 24 microg/mL in plasma, and 0.48 to 24 microg/mL in urine, both intra- and inter-day precision of the mangiferin were determined and their RSD did not exceed 10%. The method provides a technique for rapid analysis of mangiferin in rat plasma and urine, which can be used in pharmacokinetic studies.  相似文献   

17.
Summary Busulfan (Myleran; 1,4-bis-(methanesulfonyloxy) butane; BU) is a bifunctional alkylating agent used in clinical practice since 1959. It is currently included at high doses in conditioning regimens for bone marrow transplantation, usually in combination with cyclo-phosphamide. A high-performance liquid chromatographic method has been developed for the determination of BU in plasma. The basis of the assay is a derivatization with sodium diethyldithiocarbamate at 32°C in the presence of 1-bromo-1-deoxy-3,6-anhydrogalactitol as internal standard. Analysis is performed on a cyano column with heptane-isopropanol-glacial acetic acid as mobile phase and UV detection at 280 nm. The calibration graph was linear in the concentration range 0.18–46.40 μM BU in plasma. The limit of detection was 0.1 μM. The precision and accuracy were between the limits required by good laboratory practice. Presented at Balaton Symposium on High-Performance Separation Methods, Siófok, Hungary, september 1–3, 1999  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号