首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Hu B  Yang S  Li M  Gu H  Chen H 《The Analyst》2011,136(18):3599-3601
The high-throughput and sensitive characterization of native proteins in biological samples is of increasing interest in multiple disciplines. Extractive electrospray ionization (EESI) forms ions of native proteins including lysozyme, α-chymotrypsin, myoglobin, human serum albumin, RNAse A and blood hemoglobin in extremely complex biosamples or PBS buffer solutions by softly depositing charges on the protein molecules. This method produces no significant conformational changes of the proteins in the ion formation process, and features direct detection of trace proteins present in biological matrices. The detection limit of low pmol L(-1) for lysozyme in untreated biological liquids such as human urine and tears was demonstrated using EESI mass spectrometry (MS), showing an attractive MS platform for the direct analysis of native proteins in actual biological samples.  相似文献   

2.
The conformation dependence of protein spectra recorded by electrospray ionization mass spectrometry (ESI-MS) is an interesting and useful phenomenon, whose origin is still the object of debate. Different mechanisms have been invoked in the attempt to explain the lower charge state of folded versus unfolded protein ions in ESI-MS, such as electrostatic repulsions, solvent accessibility, charge availability, and native-like interactions. In this work we try to subject to direct experimental test the hypothesis that conformation-dependent neutralization of charges with polarity opposite to the net charge of the protein ion could play a critical role in such an effect. We present results of time-of-flight nano-ESI-MS on the peptide angiotensin II, indicating that negative charges of carboxylate groups can contribute to spectra recorded in positive-ion mode when stabilized by favorable electrostatic interactions, which is the central assumption of our hypothesis. Comparison of horse and spermwhale myoglobin (Mb) shows that changing the total number of basic residues within a given three-dimensional structure shifts the charge-state distribution (CSD) of the folded protein in positive-ion mode. This result appears to be in contrast to models in which electrostatic repulsions or availability of charges in the ESI droplets represent the limiting factor for the ionization of folded protein ions in ESI-MS. At the same time, it suggests a role of acidic residues in conformational effects in positive-ion mode. Furthermore, an attempt is made to rationalize those cases in which, in contrast, the main charge state observed in ESI-MS under non-denaturing conditions deviates considerably from the net charge expected on the basis of the amino-acid composition. These cases usually correspond to proteins with quite balanced content in basic and acidic residues, suggesting that this might be a factor influencing their charging behavior in ESI-MS. Experiments on mutants of ribonuclease Sa (RNase Sa) reveal that progressively reducing the excess of acidic residues, replacing them by lysine, causes almost no shift in the spectrum of the folded protein in negative-ion mode. Analogously, variants with an excess of three or five basic residues give similar spectra in positive-ion mode. These results indicate a lower limit to the extent of ionization observable by ESI-MS (6- or 8+ in the case of RNase Sa in water). Below such limit of net charge, changes in the relative amount of ionizable side chains do not affect the qualitative features of the observed CSDs. A progressive loss of signal intensity caused by the mutations in negative-ion mode suggests that low charge states might also be counterselected, even within the m/z range theoretically accessible to the instrument.  相似文献   

3.
Electrospray ionization (ESI) of denatured proteins produces a broad distribution of multiply-charged ions leading to multiple peaks in the mass spectrum. We investigated changes in the positive-mode ESI charge state distribution produced by several chemical modifications of denatured proteins. Capping carboxylic acid groups with neutral functional groups yields little change in charge state distribution compared with unmodified proteins. The results indicate that carboxyl groups do not play a significant role in the positive charging of denatured proteins in ESI. The modification of proteins with additional basic sites or fixed positive charges generates substantially higher charge states, providing evidence that the number of ionizable sites, rather than molecular size and shape, determines ESI charging for denatured proteins. Fixed charge modification also significantly reduces the number of protons acquired by a protein, in that the charge state envelope is not increased by the full number of fixed charges appended. This result demonstrates that Coulombic repulsion between positive charges plays a significant role in determining charge state distribution by affecting the gas-phase basicity of ionizable sites. Addition of fixed-charge moieties to a protein is a useful approach for shifting protein charge state distributions to higher charge states, and with further work, it may help limit the distribution of protein ions to fewer charge states.  相似文献   

4.
Effects of covalent intramolecular bonds, either native disulfide bridges or chemical crosslinks, on ESI supercharging of proteins from aqueous solutions were investigated. Chemically modifying cytochrome c with up to seven crosslinks or ubiquitin with up to two crosslinks did not affect the average or maximum charge states of these proteins in the absence of m-nitrobenzyl alcohol (m-NBA), but the extent of supercharging induced by m-NBA increased with decreasing numbers of crosslinks. For the model random coil polypeptide reduced/alkylated RNase A, a decrease in charging with increasing m-NBA concentration attributable to reduced surface tension of the ESI droplet was observed, whereas native RNase A electrosprayed from these same solutions exhibited enhanced charging. The inverse relationship between the extent of supercharging and the number of intramolecular crosslinks for folded proteins, as well as the absence of supercharging for proteins that are random coils in aqueous solution, indicate that conformational restrictions induced by the crosslinks reduce the extent of supercharging. These results provide additional evidence that protein and protein complex supercharging from aqueous solution is primarily due to partial or significant unfolding that occurs as a result of chemical and/or thermal denaturation induced by the supercharging reagent late in the ESI droplet lifetime.  相似文献   

5.
Earlier work from this laboratory dealt with the observation that the charge states of non-denatured proteins can be decreased by use of buffer salts in which the gas-phase basicity of conjugate base B, GB(B), of the buffer cations is high. A theoretical model was developed and applied to several small proteins. The predictions of the charge states were found to be in good agreement with those observed experimentally. Because the computational model is based on the charge residue model (CRM), the observed agreement lends support for the CRM. In the present work, the same model is applied to recent data by Catalina et al. who showed that very large charge reductions are achieved with very high GB(B) proton sponges. Their data included lysozyme but also the very much larger proteins, p-hydroxybenzoate hydroxylase (PHBH), 90 kDa and glutamate synthase (GLTS), 166 kDA. The present work examines the performance of the model for the much stronger bases and the very much larger proteins. It is found that the predictions of the charge states agree well for the small protein lysozyme but somewhat less well with the experimental results for PHBH and GLTS. The causes for the lack of good agreement with the large proteins are examined.  相似文献   

6.
The formation of metal‐peptide complexes during electrospray ionization (ESI) is a widely known phenomenon and is often considered to be undesirable. Such effect considerably limits the use of ESI mass spectrometry for the investigation of biologically relevant metal‐peptide compounds that are present in the solution and play critical roles in many bioprocesses such as progression of neurodegenerative diseases. In the article, it is demonstrated that under specific conditions such as high temperature of the desolvating capillary, an interesting effect, which can be called as ‘supermetallization’, occurs. Using a model peptide Αβ amyloid domain 1–16, it was observed that an increase in the temperature of the desolvating capillary results in multiple substitutions of hydrogen atoms by Zn atoms in this peptide. At high temperatures (T ~ 400 °C), up to 11 zinc atoms can be covalently bound to (1–16) Αβ. It was observed that supermetallization of (1–16) Αβ depends on the solvent composition and pH. Supermetallization was also demonstrated for proteins, such as ubiquitin and cytochrome C. That proves that the supermetallization is a general phenomenon for peptides and proteins. For the structural investigation of supermetallized complexes, electron‐capture dissociation (ECD) fragmentation was applied. The effect of hydrogen rearranging during ECD was observed. In addition, quantum chemical calculations were used to estimate the possible structures of different supermetallized complexes. These results allow a more deep understanding of the limitations of the use of ESI mass spectrometry for the investigation of biologically relevant metal‐peptide complexes. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
An experimental investigation and theoretical analysis are reported on charge competition in electrospray ionization (ESI) and its effects on the linear dynamic range of ESI mass spectrometric (MS) measurements. The experiments confirmed the expected increase of MS sensitivities as the ESI flow rate decreases. However, different compounds show somewhat different mass spectral peak intensities even at the lowest flow rates, at the same concentration and electrospray operating conditions. MS response for each compound solution shows good linearity at lower concentrations and levels off at high concentration, consistent with analyte "saturation" in the ESI process. The extent of charge competition leading to saturation in the ESI process is consistent with the relative magnitude of excess charge in the electrospray compared to the total number of analyte molecules in the solution. This ESI capacity model allows one to predict the sample concentration limits for charge competition and the on-set of ionization suppression effects, as well as the linear dynamic range for ESI-MS. The implications for quantitative MS analysis and possibilities for effectively extending the dynamic range of ESI measurements are discussed.  相似文献   

8.
Acidic proteins and nucleic acids such as RNA are most readily ionized in electrospray ionization (ESI) operated in negative-ion mode. The multiply deprotonated protein or RNA ions can be used as precursors in top- down mass spectrometry. Because the performance of the dissociation method used critically depends on precursor ion negative net charge, it is important that the extent of charging in ESI can be manipulated efficiently. We show here that (M - nH)(n-) ion net charge of proteins and RNA can be controlled efficiently by the addition of organic bases to the electrosprayed solution. Our study also highlights the fact that ion formation in ESI in negative mode is only poorly understood.  相似文献   

9.
Correct charge state assignment is crucial to assigning an accurate mass to supramolecular complexes analyzed by electrospray mass spectrometry. Conventional charge state assignment techniques fall short of reliably and unambiguously predicting the correct charge state for many supramolecular complexes. We provide an explanation of the shortcomings of the conventional techniques and have developed a robust charge state assignment method that is applicable to all spectra.  相似文献   

10.
A model for the gas-phase proton transfer reactivity of multiply protonated molecules is used to quantitatively account for the maximum charge states of a series of arginine-containing peptide ions measured by Downard and Biemann (Int. J. Mass Spectrom. Ion Processes 1995, 148, 191-202). We find that our calculations account exactly for the maximum charge state for 7 of the 10 peptides and are off by one charge for the remaining 3. These calculations clearly predict the trend in maximum charge states for these peptides and provide further evidence that the maximum charge state of ions formed by electrospray ionization is determined by their gas-phase proton transfer reactivity.  相似文献   

11.
Mechanistic investigation of ionization suppression in electrospray ionization   总被引:10,自引:0,他引:10  
We show results from experiments designed to determine the relative importance of gas phase processes and solution phase processes into ionization suppression observed in biological sample extracts. The data indicate that gas phase reactions leading to the loss of net charge on the analyte is not likely to be the most important process involved in ionization suppression. The results point to changes in the droplet solution properties caused by the presence of nonvolatile solutes as the main cause of ionization suppression in electrospray ionization of biological extracts.  相似文献   

12.
An investigation of the nonspecific association of small charged biomolecules and proteins in electrospray ionization mass spectrometry (ES-MS) is described. Aqueous solutions containing pairs of proteins and a small acidic or basic biomolecule that does not interact specifically with either of the proteins were analyzed by ES-MS and the distributions of the biomolecules bound nonspecifically to each pair of proteins compared. For the basic amino acid arginine and the peptide RGVFRR, nonequivalent distributions were measured in positive ion mode, but equivalent distributions were measured in negative ion mode. In the case of uridine 5′-diphosphate, nonequivalent distributions were measured in negative ion mode, but equivalent distributions observed in positive ion mode. The results of dissociation experiments performed on the gaseous ions of the nonspecific complexes suggest that the nonequivalent distributions result from differences in the extent to which the nonspecific complexes undergo in-source dissociation. To test this hypothesis, the distributions of nonspecifically bound basic molecules measured in the presence of imidazole, which protects complexes from in-source dissociation, were compared. In all cases, equivalent distributions were obtained. The results indicate that nonspecific binding of charged molecules to proteins during ES is a statistical process, independent of protein structure and size. However, the kinetic stabilities of the nonspecific interactions are sensitive to the nature of the protein ions. It is concluded that the reference protein method for correcting ES mass spectra for nonspecific ligand-protein binding can be applied to the analysis of ionic ligands, provided that in-source dissociation of the nonspecific interactions is minimized.  相似文献   

13.
The effects of solvent composition on both the maximum charge states and charge state distributions of analyte ions formed by electrospray ionization were investigated using a quadrupole mass spectrometer. The charge state distributions of cytochrome c and myoglobin, formed from 47%/50%/3% water/solvent/acetic acid solutions, shift to lower charge (higher m/z) when the 50% solvent fraction is changed from water to methanol, to acetonitrile, to isopropanol. This is also the order of increasing gas-phase basicities of these solvents, although other physical properties of these solvents may also play a role. The effect is relatively small for these solvents, possibly due to their limited concentration inside the electrospray interface. In contrast, the addition of even small amounts of diethylamine (<0.4%) results in dramatic shifts to lower charge, presumably due to preferential proton transfer from the higher charge state ions to diethylamine. These results clearly show that the maximum charge states and charge state distributions of ions formed by electrospray ionization are influenced by solvents that are more volatile than water. Addition of even small amounts of two solvents that are less volatile than water, ethylene glycol and 2-methoxyethanol, also results in preferential deprotonation of higher charge state ions of small peptides, but these solvents actually produce an enhancement in the higher charge state ions for both cytochrome c and myoglobin. For instruments that have capabilities that improve with lower m/z, this effect could be taken advantage of to improve the performance of an analysis.  相似文献   

14.
This review reports the results of some studies carried out by us on the role of pneumatic aspects in electrospray and desorption electrospray surface ionization, with the aim to propose some relevant aspects of the mechanisms involved in these ionization methods. Electrospray ion sources, with the exception of the nano- electrospray source, operate with the concurrent action of a strong electrical field and a supplementary coaxial gas flow. The electrical field is responsible for electrospraying of the analyte solution but the use of a coaxial gas flow leads to a significant increase of the analyte signal and allows the use of higher solution flows. However, by employing capillary voltages much lower than those necessary to activate the electrospray phenomenon, analyte ions are still observed and this indicates that different mechanisms must be operative for ion production. Under these conditions, ion generation could take place from the neutral pneumatically sprayed droplet by field-induced droplet ionization. Also in the case of desorption electrospray ionization (DESI), and without any voltage on the spraying capillary as well as on the surface of interest, ions of analytes present on the surface become detectable and this shows that desorption/ionization of analytes occurs by neutral droplets impinging the surface. Consequently, the pneumatic effect of the impinging droplets plays a relevant role, and for these reasons the method has been called pneumatic assisted desorption (PAD). Some analogies existing between PAD and surface activated chemical ionization (SACI), based on the insertion of a metallic surface inside an atmospheric pressure chemical ionization source operating without corona discharge, are discussed.  相似文献   

15.
Herein we report a novel calibration routine for use in positive ion mode electrospray ionization mass spectrometry (ESI-MS). Monoisotopic masses were calculated for a series of water clusters and used as calibration reference files (available at http://www.hbcg.utmb.edu/xray). The water cluster series contains singly charged peaks every 18 Da, which allows calibration curves to be precisely defined over a broad mass-to-charge ratio range. Water clusters, induced by a combination of high flow rate and high cone voltage, were used to accurately calibrate a quadrupole mass spectrometer from 100 to 1900 m/z. Calibration curves thus generated have many more data points and greatly reduced standard deviations compared to those obtained from myoglobin, sodium iodide, cesium iodide, or poly(ethylene glycol) based calibration standards. This calibration routine reduces the error in protein mass measurements by a factor of 3, from ±0.01% to ±0.0035% at the 95% confidence limit. The implications of this increased mass accuracy and wider calibrated mass-to-charge ratio scale for the study of protein sequence, structure, and folding by ESI-MS are discussed.  相似文献   

16.
The [M + 20H](20+)-[M + 12H](12+) charge states of native and reduced porcine elastase, a 25.9 kDa serine protease, were subjected to collisional activation in a quadrupole ion trap. For most charge states, ion parking was used to increase the number of parent ions over that yielded directly by electrospray. Ion-ion proton transfer reactions were used to reduce product ion charge states largely to +1 to simplify spectral interpretation. Both forms of the protein show charge state dependent fragmentation behavior. The native protein, which contains four disulfide linkages, shows almost no evidence for fragmentation within the regions of the protein linked by disulfide bonds. However, at the lowest charge states studied, evidence for cleavage of a least one of the disulfide bonds was evident in the appearance of a c-type ion. The highest charge states of native elastase showed several prominent cleavages C-terminal to valine residues. As the charge state decreased, however, preferential cleavages at acidic amino acid residues became important. The reduced form of the protein did not show particularly prominent cleavages at valine residues. However, many of the same preferential cleavages at acidic amino acid residues noted for the native protein were also observed in the same charge states of the reduced protein. The reduced protein also showed additional cleavages from regions of the protein that are ordinarily protected by disulfide linkages in the native form.  相似文献   

17.
Hitherto analysis of chemicals in the field using mass spectrometry (MS) has been limited to analysis of non-polar and thermally stabile organic compounds using either a direct gas leak or a membrane inlet as MS interface. Recently, Professor R. Graham Cooks’ group demonstrated that miniature mass spectrometers operating at elevated pressures (>0.13?Pa (1?·?10?3??Torr)) can be combined with electrospray ionization (ESI) for analysis of polar as well as thermally labile organic compounds. We present a simple miniaturized ESI unit for analysis of small liquid samples using miniature mass spectrometry. The ESI unit operates without pumps and supplementary sheath gases, which makes it very simple to handle in the field. 20–30?µL of sample solution is simply dropped into a small cavity in the ESI unit, where after the spray is initiated by applying high voltage to it. The miniaturized ESI unit was tested in combination with a miniature mass spectrometer (the Mini 10 developed by Professor R. Graham Cooks, Purdue University, IN) and we found that common herbicides (Atrazine, Prometryne, Terbutryne and Triadimefone) could be detected with detection limits around 1?mg?L?1 and with a quantitative reproducibility of +/?30%. These characteristics, although high for environmental samples, are comparable to detection limits obtained with other ESI units used with miniature mass spectrometers and represent an early step forward towards a future field instrument. A major advantage of the capillary spray cell is its direct compatibility with micro extraction techniques for sample pre-concentration.  相似文献   

18.
Changes in protein conformation are thought to alter charge state distributions observed in electrospray ionization mass spectra (ESI-MS) of proteins. In most cases, this has been demonstrated by unfolding proteins through acidification of the solution. This methodology changes the properties of the solvent so that changes in the ESI-MS charge envelopes from conformational changes are difficult to separate from the effects of changing solvent on the ionization process. A novel strategy is presented enabling comparison of ESI mass spectra of a folded and partially unfolded protein of the same amino acid sequence subjected to the same experimental protocols and conditions. The N-terminal domain of the Escherichia coli DnaB protein was cyclized by in vivo formation of an amide bond between its N- and C-termini. The properties of this stabilized protein were compared with its linear counterpart. When the linear form was unfolded by decreasing pH, a charge envelope at lower m/z appeared consistent with the presence of a population of unfolded protein. This was observed in both positive-ion and negative-ion ESI mass spectra. Under the same conditions, this low m/z envelope was not present in the ESI mass spectrum of the stable cyclized form. The effects of changing the desolvation temperature in the ionization source of the Q-TOF mass spectrometer were also investigated. Increasing the desolvation temperature had little effect on positive-ion ESI mass spectra, but in negative-ion spectra, a charge envelope at lower m/z appeared, consistent with an increase in the abundance of unfolded protein molecules.  相似文献   

19.
王小淳  金燕 《色谱》2000,18(4):332-334
 应用高效液相色谱法将脂肪醇聚氧乙烯醚按碳数和环氧乙烷加成数 (EO数 )分离后 ,在线联用电喷雾离子化质谱 (ESI MS) ,根据其一系列准分子离子峰判断烷基链长和环氧乙烷聚合度。解释了准分子离子峰强度失真的原因。  相似文献   

20.
Bovine surfactant proteins B (SP-B) and C (SP-C) were analyzed by nano-electrospray ionization mass spectrometry (nano-ESI-MS). The observed molecular masses showed discrepancies compared to the calculated molecular masses using the published amino acid sequences. The number of cysteine residues in the published bovine SP-B amino acid sequences also failed to match the observed mass shift upon reduction of the SP-B dimer. To determine the amino acid sequences of two proteins, SP-B was first digested with trypsin and analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS), while SP-C was analyzed by MS/MS in its intact form. The amino acid sequence of bovine SP-B determined here matches the observed molecular mass. The sequence is almost identical to the sheep SP-B except for two amino acid residues, consistent with the proximity of the two species. The correct sequence contains seven cysteine residues. Bovine SP-B exists as dimers and all cysteines are oxidized to form disulfide bonds in physiological conditions, which is in agreement with the observed mass shift upon reduction of the SP-B dimer. These cysteine residues are completely conserved across all species indicating their importance for the biological functions of this surfactant protein. The sequence of SP-C determined here also reveals an L to V substitution at its position 22 compared with the published bovine SP-B sequence.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号