1.
Hydrophilic interaction chromatography (HILIC) is becoming increasingly popular for separation of polar samples on polar columns in aqueous-organic mobile phases rich in organic solvents (usually ACN). Silica gel with decreased surface concentration of silanol groups, or with chemically bonded amino-, amido-, cyano-, carbamate-, diol-, polyol-, or zwitterionic sulfobetaine ligands are used as the stationary phases for HILIC separations, in addition to the original poly(2-sulphoethyl aspartamide) strong cation-exchange HILIC material. The type of the stationary and the composition of the mobile phase play important roles in the mixed-mode HILIC retention mechanism and can be flexibly tuned to suit specific separation problems. Because of excellent mobile phase compatibility and complementary selectivity to RP chromatography, HILIC is ideally suited for highly orthogonal 2-D LC-LC separations of complex samples containing polar compounds, such as peptides, proteins, oligosaccharides, drugs, metabolites and natural compounds. This review attempts to present an overview of the HILIC separation systems, possibilities for their characterization and emerging HILIC applications in 2-D off-line and on-line LC-LC separations of various samples, in combination with RP and other separation modes.  相似文献   

2.
Hydrophilic interaction chromatography (HILIC) is valuable alternative to reversed-phase liquid chromatography separations of polar, weakly acidic or basic samples. In principle, this separation mode can be characterized as normal-phase chromatography on polar columns in aqueous-organic mobile phases rich in organic solvents (usually acetonitrile). Highly organic HILIC mobile phases usually enhance ionization in the electrospray ion source of a mass spectrometer, in comparison to mobile phases with higher concentrations of water generally used in reversed-phase (RP) LC separations of polar or ionic compounds, which is another reason for increasing popularity of this technique. Various columns can be used in the HILIC mode for separations of peptides, proteins, oligosaccharides, drugs, metabolites and various natural compounds: bare silica gel, silica-based amino-, amido-, cyano-, carbamate-, diol-, polyol-, zwitterionic sulfobetaine, or poly(2-sulphoethyl aspartamide) and other polar stationary phases chemically bonded on silica gel support, but also ion exchangers or zwitterionic materials showing combined HILIC-ion interaction retention mechanism. Some stationary phases are designed to enhance the mixed-mode retention character. Many polar columns show some contributions of reversed phase (hydrophobic) separation mechanism, depending on the composition of the mobile phase, which can be tuned to suit specific separation problems. Because the separation selectivity in the HILIC mode is complementary to that in reversed-phase and other modes, combinations of the HILIC, RP and other systems are attractive for two-dimensional applications. This review deals with recent advances in the development of HILIC phase separation systems with special attention to the properties of stationary phases. The effects of the mobile phase, of sample structure and of temperature on separation are addressed, too.  相似文献   

3.
Sta&#;kov&#;  Magda  Jandera  Pavel 《Chromatographia》2016,79(11):657-666

In-house prepared zwitterionic polymethacrylate micro-columns using in situ polymerization of N,N-dimethyl-N-metacryloxyethyl-N-(3-sulfopropyl) ammonium betaine (MEDSA) functional monomer with bisphenol A glycerolate dimethacrylate (BIGDMA) cross-linker provided excellent stability and reproducibility of preparation and separation efficiency of 60,000–70,000 theoretical plates m−1 for small molecules under isocratic conditions. The column showed a dual retention mechanism, reversed-phase (RP) in highly aqueous mobile phases and aqueous normal-phase (HILIC) in acetonitrile-rich mobile phases. This property can be used to obtain complementary separation and combined information on the sample from repeated injections of a sample on a single column, in different mobile phases characteristic for the HILIC and for the RP modes, which is in fact a form of offline two-dimensional chromatography on a single column. The dual retention mechanism has been observed with a variety of columns, however, often with impractically narrow retention range in one of the two modes. To take full advantage from the combined single-column RP–HILIC experiments, the column should provide a sufficiently broad mobile phase interval both in the RP and in the HILIC mode. The BIGDMA-MEDSA micro-columns proved suitable earlier for the combined RP–HILIC separations of some phenolic compounds and flavonoids. In the present work, we investigated the effects of the mobile phase composition on the retention of a variety of polar compounds over full retention range of buffered aqueous acetonitrile mobile phases, to find potentially useful HILIC and RP retention ranges for barbiturates, sulfonamides, nucleosides and nucleic bases. In the HILIC mode, proton donor–acceptor interactions show a major effect on retention and selectivity of separation, whereas the size of the non-polar hydrocarbon part of the sample molecule is the most important factor in the water-rich mobile phases. The sample structure strongly affects the composition of aqueous–organic mobile phases at which the transition between the two retention modes occurs. Of the investigated sample types, barbiturates show better separation under reversed-phase conditions, whereas nucleosides and nucleic bases in the HILIC mode. Aromatic carboxylic acids and sulfonamides can be separated either in the reversed phase or under HILIC conditions, the two separation modes showing complementary selectivity of separation.

  相似文献   

4.
We have developed a novel system for coupling reverse-phase (RP) and hydrophilic interaction liquid chromatography (HILIC) online in a micro-flow scheme. In this approach, the inherent solvent incompatibility between RP and HILIC is overcome through the use of constant-pressure online solvent mixing, which allows our system to perform efficient separations of both hydrophilic and hydrophobic compounds for mass spectrometry-based proteomics applications. When analyzing the tryptic digests of bovine serum albumin, ribonuclease B, and horseradish peroxidase, we observed near-identical coverage of peptides and glycopeptides when using online RP-HILIC—with only a single sample injection event—as we did from two separate RP and HILIC analyses. The coupled system was also capable of concurrently characterizing the peptide and glycan portions of deglycosylated glycoproteins from one injection event, as confirmed, for example, through our detection of 23 novel glycans from turkey ovalbumin. Finally, we validated the applicability of using RP-HILIC for the analysis of highly complex biological samples (mouse chondrocyte lysate, deglycosylated human serum). The enhanced coverage and efficiency of online RP-HILIC makes it a viable technique for the comprehensive separation of components displaying dramatically different hydrophobicities, such as peptides, glycopeptides, and glycans.  相似文献   

5.
Separation science is an art of obtaining adequate resolution of the desired compounds in minimum time, and with minimum effort in terms of sample preparation and data evaluation. In LC, where selectivity is a main driving force for separation, the availability of different separation modes capable of operating at high flow rates is a way to make combined optimal use of selectivity, efficiency, and speed. The separation of polar and hydrophilic compounds is problematic in RP LC due to the poor retention. Hydrophilic interaction liquid chromatography (HILIC) is a more straightforward separation mode to address this problem. Herein, it is shown that separations in HILIC mode are equally efficient as for RP, providing a potential for very fast separations on short columns. This is not only facilitated by the low viscosity of the mobile phase compositions used, compared to typical RP eluents, but also due to higher column permeability. To exemplify this, baseline separations of uracil and cytosine are shown in less than 4 s and of Tamiflu and its main metabolite in less than 40 s, both under isocratic conditions. HILIC must therefore be considered having potential for high throughput purposes, and being an attractive candidate as the second separation dimension in 2-D HPLC.  相似文献   

6.
Jia S  Park JH  Lee J  Kwon SW 《Talanta》2011,85(5):2301-2306
Comparison of hydrophilic interaction chromatography (HILIC) columns coupled with an evaporative light scattering detector (ELSD) or charged aerosol detector (CAD) was done for the detection of gabapentin in pharmaceutical formulations. The chromatographic separations were achieved on four HILIC columns: ZIC HILIC, ZIC pHILIC, Luna HILIC, and Atlantis HILIC. Experimental factors such as mobile phase composition, acetonitrile content, and mobile phase pH were evaluated. Validation of method was done in terms of linearity, sensitivity, accuracy, and precision. The performance of ELSD detection method is comparable to that of CAD. The intra-day and inter-day variations were below 1.7% and 3.2% for CAD and 2.8%, and 3.4% for ELSD, respectively. In addition, detection sensitivities of ELSD, CAD, and UV detectors were also compared for HILIC and reversed phase (RP) modes and the highest sensitivities were obtained in the HILIC mode when connected with CAD and ELSD. The developed HILIC aerosol based detection methods were successfully applied to the analysis of gabapentin in commercial tablets and capsules.  相似文献   

7.
Many samples contain compounds with various numbers of two or more regular structural groups. Such "multidimensional" samples (according to the Giddings' notation) are best separated in orthogonal chromatographic systems with different selectivities for the individual repeat structural groups, described by separation factors. Correlations between the repeat group selectivities characterize the degree of orthogonality and suitability of chromatographic systems for two-dimensional (2D) separations of two-dimensional samples. The range of the structural units in that can be resolved in a given time can be predicted on the basis of a model describing the repeat group selectivity in the first- and second-dimension systems. Two-dimensional liquid chromatographic system combining reversed-phase (RP) mode in the first dimension and normal-phase (NP) mode in the second dimension were studied with respect to the possibilities of in-line fraction transfer between the two modes. Hydrophilic interaction liquid chromatography (HILIC) with an aminopropyl silica column (APS) is more resistant than classical non-aqueous NP systems against adsorbent desactivation with aqueous solvents transferred in the fractions from the first, RP dimension to the second dimension. Hence, HILIC is useful as a second-dimension separation system for comprehensive RP-NP LCxLC. A comprehensive 2D RP-NP HPLC method was developed for comprehensive 2D separation of ethylene oxide-propylene oxide (EO-PO) (co)oligomers. The first-dimension RP system employed a 120 min gradient of acetonitrile in water on a C18 microbore column at the flow-rate of 10 microL/min. In the second dimension, isocratic HILIC NP with ethanol-dichloromethane-water mobile phase on an aminopropyl silica column at 0.5 mL/min was used. Ten microliter fractions were transferred from the RP to the HILIC NP system at 1 min switching valve cycle frequency.  相似文献   

8.
In this study, the analysis of a peptide set, chosen for their differences in hydrophilicity, and the tryptic digests of bovine cytochrome c and β-lactoglobulin by hydrophilic interaction chromatography–electrospray ionisation mass spectrometry (HILIC–ESI-MS) is demonstrated. Two different types of HILIC phases, i.e., an amide- and an amino-modified silica-based phase, packed into narrow bore or capillary columns, were investigated with separations conducted under either low pH or neutral pH conditions. The separation performance of the two HILIC columns with respect to peak efficiency and selectivity have been documented under these different mobile phase conditions, and the results compared with the performance of a conventional capillary reversed-phase C18 column of similar dimensions. It was found that very good separation of the peptide set could be achieved by using the amide-modified silica column over a broad pH range. Moreover, with the protein digest samples, excellent separation of the tryptic digests was obtained with the amide-modified HILIC column under neutral pH conditions. Compared to the conventional reversed-phase C18 separations, the use of these HILIC columns not only provided complementary separation selectivity, but also offered the capability to identify unique peptides using tandem HILIC–mass spectrometric techniques. These studies therefore highlight the potential of HILIC procedures for future proteomic applications.  相似文献   

9.
Two new ultra-high performance liquid chromatography (UHPLC) methods for analyzing 21 selected antivirals and their metabolites were optimized, including sample preparation step, LC separation conditions, and tandem mass spectrometry detection. Micro-solid phase extraction in pipette tips was used to extract antivirals from the biological material of Hanks balanced salt medium of pH 7.4 and 6.5. These media were used in experiments to evaluate the membrane transport of antiviral drugs. Challenging diversity of physicochemical properties was overcome using combined sorbent composed of C18 and ion exchange moiety, which finally allowed to cover the whole range of tested antivirals. For separation, reversed-phase (RP) chromatography and hydrophilic interaction liquid chromatography (HILIC), were optimized using extensive screening of stationary and mobile phase combinations. Optimized RP-UHPLC separation was carried out using BEH Shield RP18 stationary phase and gradient elution with 25 mmol/L formic acid in acetonitrile and in water. HILIC separation was accomplished with a Cortecs HILIC column and gradient elution with 25 mmol/L ammonium formate pH 3 and acetonitrile. Tandem mass spectrometry (MS/MS) conditions were optimized in both chromatographic modes, but obtained results revealed only a little difference in parameters of capillary voltage and cone voltage. While RP-UHPLC-MS/MS exhibited superior separation selectivity, HILIC-UHPLC-MS/MS has shown substantially higher sensitivity of two orders of magnitude for many compounds. Method validation results indicated that HILIC mode was more suitable for multianalyte methods. Despite better separation selectivity achieved in RP-UHPLC-MS/MS, the matrix effects were noticed while using both chromatographic modes leading to signal enhancement in RP and signal suppression in HILIC.  相似文献   

10.
Acetonitrile–water extracts of several Ganoderma species – a mushroom being used in Traditional Chinese Medicine – were analysed by liquid chromatography–UV detection in hydrophilic interaction chromatography (HILIC) and reversed-phase (RP) elution modes. A set of six polar stationary phases was used for HILIC runs. These columns had remarkably different separation properties under binary gradient conditions as evinced by hierarchical cluster analysis on retention patterns of seven test compounds. Complementary measurements of RP chromatograms were carried out on a C18 packing. Injection precision (n = 5) and intra-day precision (n = 5) were each <2.0% RSD (HILIC) and <0.7% RSD (RP) for relative retention times of main characteristic peaks of a sample extract while for relative peak areas RSD values were max. 6.8%. Repetitive analysis (n = 7) of a processed sample stored in the autosampler tray for 48 h was used to confirm within-sequence sample stability. Eleven Ganoderma lucidum samples served as training set for the construction of column-specific simulated mean chromatograms. Validation with twelve samples comprising G. lucidum, Ganoderma sinense, Ganoderma atrum, and Ganoderma tsugae by correlation coefficient based similarity evaluation of peak patterns showed that a discrimination of G. lucidum from other Ganoderma species by means of chromatographic fingerprints is conceptually possible on all columns, except of a bare silica packing. The importance of the combined use of RP and HILIC fingerprints to improve the rate of correct sample classification was demonstrated by the fact that each one G. sinense specimen was wrongly assigned being G. lucidum by all HILIC fingerprints but not the RP fingerprint and vice versa. The present data revealed that (i) the analysis of complex biological materials by quasi orthogonal chromatographic modes such as HILIC and RP may deliver more discriminative information than single-mode approaches which strengthens the reliability of fingerprint-based sample classification and (ii) different retention and selectivity characteristics of polar bonded silica packings in the HILIC elution mode may only have a minor impact on chemometric sample discrimination capabilities in such kind of pattern-oriented metabolomics separation problems.  相似文献   

11.
Hydrophilic interaction chromatography (HILIC) was employed to separate the co-eluted flavonoids from licorice extract under RP-HPLC mode. HILIC separations were carried out with the Atalantis HILIC Silica column and the CD-based column. The co-eluted flavonoids were well retained and separated on the two HILIC columns under HILIC mode. Similar results were obtained in the separation of another isoflavones sample, from kudzu extract under HILIC mode.  相似文献   

12.
In this study we developed and optimized a column-switching high-performance liquid chromatographic (HPLC) system for the complementary analysis of polar and apolar compounds in complex samples. The polar compounds are separated on a hydrophilic interaction chromatographic (HILIC) column; the part of the sample non-retained on HILIC is transferred into and separated on a reversed-phase (RP) column through an interface, thus preventing the loss of analytes eluting at dead time in common single-column mode. The signals are in turn recorded in the same chromatogram either by a UV or by a mass spectrometric detector. Applying a mixture of 25 standard compounds (12 hydrophilic and 13 hydrophobic) the system proves to be reliable, robust and easy-operating. The investigation of urine revealed an increase in the detected metabolite ion masses compared to the single-column HILIC-electrospray ionization (ESI)-MS analysis. Utilizing online the complementary selectivity of HILIC and RPLC in a fully automatic mode, this approach holds out the prospect to enlarge the number of detectable compounds in non-targeted "-omics" studies and sophisticated target-driven approaches by a single injection.  相似文献   

13.
Preparation methods of monolithic silica columns for HPLC including the surface modification were reviewed. Chemical modification methods recently reported to obtain stationary phases for reversed-phase (RP), chiral, ion-exchange, and hydrophilic interaction chromatography (HILIC) separations were discussed. Recent results related to preparation methods of monolithic silica were also covered. The characteristics and properties of silica monoliths and some applications of monolithic silica columns for different analytical and bioanalytical fields will be commented.  相似文献   

14.
The determination of catecholamines in urine was investigated using hydrophilic interaction chromatography (HILIC) as an alternative to the commonly used reversed-phase (RP) method. A number of different approaches were explored, including per-aqueous liquid chromatography (PALC), and HILIC using bare silica, bonded amide and zwitterionic phases. The bonded phases gave superior results in terms of both peak shape and selectivity. The mechanism of the HILIC separation was investigated particularly with respect to the contribution of ion exchange to retention. The electrochemical detection of catecholamines was studied and optimised in typical HILIC mobile phases that contain high concentrations of acetonitrile. HILIC offered a number of advantages over the conventional RP approach, giving good retention of the solutes without use of ion pair reagents, the absence of which also would facilitate detection by mass spectrometry. HILIC used in conjunction with solid phase extraction based on RP also gives orthogonal separation mechanisms in the cleanup and analysis steps. Furthermore, good recoveries from the cleanup stage were obtained, as high concentrations of acetonitrile can be used as eluting solvent that are fully compatible with HILIC, and lipophilic impurities are eluted close to the void volume of the HILIC column.  相似文献   

15.
Fingerprint analysis is considered one of the most powerful approaches to quality control in traditional Chinese medicines (TCMs). In this study, a binary chromatographic fingerprint analysis was developed using hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) to gain more chemical information about polar compounds and weakly polar compounds. This method was used to construct a chromatographic fingerprint of Ligusticum chuanxiong. The two chromatographic methods demonstrated good precision, reproducibility, and stability, with relative standard deviations of <2% for retention time and 7% for peak area for both HILIC and RPLC separations. Data from the analysis of 14 samples by HILIC and RPLC were processed with similarity analysis, with correlation coefficients and congruence coefficients. This binary fingerprint analysis, using two chromatographic modes, is a powerful tool for characterizing the quality of samples, and can be used for the comprehensive quality control of TCMs.  相似文献   

16.
We prepared hybrid particle-monolithic polymethacrylate columns for micro-HPLC by in situ polymerization in fused silica capillaries pre-packed with 3–5 μm C18 and aminopropyl silica bonded particles, using polymerization mixtures based on laurylmethacrylate–ethylene dimethacrylate (co)polymers for the reversed-phase (RP) mode and [2-(methacryloyloxy)ethyl]-dimethyl-(3-sulfopropyl) zwitterionic (co)polymers for the hydrophilic interaction (HILIC) mode. The hybrid particle-monolithic columns showed reduced porosity and hold-up volumes, approximately 2–2.5 times lower in comparison to the pure monolithic columns prepared in the whole volume of empty capillaries. The elution volumes of sample compounds are also generally lower in comparison to packed or pure monolithic columns. The efficiency and permeability of the hybrid columns are intermediate in between the properties of the reference pure monolithic and particle-packed columns. The chemistries of the embedded solid particles and of the interparticle monolithic moiety in the hybrid capillary columns contribute to the retention to various degrees, affecting the selectivity of separation. Some hybrid columns provided improved separations of proteins in comparison to the reference particle-packed columns in the reversed-phase mode. Zwitterionic hybrid particle-monolithic columns show dual mode retention HILIC/RP behaviour depending on the composition of the mobile phase and allow separations of polar compounds such as phenolic acids in the HILIC mode at lower concentrations of acetonitrile and, often in shorter analysis time in comparison to particle-packed and full-volume monolithic columns.  相似文献   

17.
A set of particulate silica-supported mixed-mode RP/weak anion-exchangers (RP/WAX) (obtained by bonding of N-undecenoylated 3-aminoquinuclidine, 3-aminotropane and 2-dimethylaminoethylamine as well as of N-butenoyl-(2S,4S,5R)-2-aminomethyl-5-[(2-octylthio)ethyl]-quinuclidine to thiol-modified silica) were chromatographically characterized in comparison to selected commercially available columns using two distinct isocratic elution modes, viz. an aqueous-rich RP-type elution mode (with 40% ACN and 60% buffer) as well as an organic solvent-rich hydrophilic interaction chromatography (HILIC)-type elution mode (95 and 90% ACN). The mixed-mode RP/WAX phases showed multimodal applicability, unlike a polar embedded RP material (Synergi Fusion RP), amino phases (Luna NH(2), BioBasic AX) or typical HILIC packings (ZIC-HILIC, TSKGel Amide-80). Principal component analysis (PCA) of the RP test data confirmed that the in-house developed RP/WAX columns as well as the Acclaim Mixed-Mode WAX-1 phase resemble each other in their chromatographic characteristics having slightly lower hydrophobic selectivity (alpha(CH2) of 1.5) than the tested Synergi Fusion RP (alpha(CH2) approximately 1.8). In contrast, a decrease in mixed-mode character due to lowered ion-exchange capacity and concomitantly increased RP-like behavior could be identified for other mixed-mode phases in the order of Obelisc R > Primesep B2 > Uptisphere MM3. PCA on HILIC data revealed that the RP/WAX phases behave dissimilar to TSKGel Amide-80, ZIC-HILIC and polysulfoethyl A under the chosen elution conditions. Hence, they may be regarded as complementary to these commercial stationary phases with applicability profiles for hydrophilic but also hydrophobic solutes.  相似文献   

18.
A stationary phase composed of silica-bonded sulfonated cyclofructan 6 (SCF6) was synthesized and evaluated for hydrophilic interaction chromatography (HILIC). The separation of a large variety of polar compounds was evaluated on different versions of the stationary phase and compared with the same separations obtained with commercially available HILIC columns. The new columns successfully separate polar and hydrophilic compounds including β blockers, xanthines, salicylic acid related compounds, nucleic acid bases, nucleosides, maltooligosaccharides, water soluble vitamins and amino acids. The separation conditions were optimized by changing the composition and the pH of the mobile phase. The dependence of analyte retention on temperature was studied using van't Hoff plots. The newly synthesized stationary phase showed broad applicability for HILIC mode separations.  相似文献   

19.
Hydrophilic-interaction liquid chromatography (HILIC), reversed-phase chromatography (RPC) and porous graphitic carbon (PGC) chromatography are typically applied for liquid chromatographic separations of protein N-glycans. Hence the performances of these chromatography modes for the separation of fluorescently labeled standard glycan samples (monoclonal antibody, fetuin, ribonuclease-B) covering high-mannose and a broad range of complex type glycans were investigated. In RPC the retention of sialylated glycans was enhanced by adding an ion-pairing agent to the mobile phase, resulting in improved peak shapes for sialylated glycans compared to methods recently reported in literature. For ion pairing RPC (IP-RPC) and HILIC ultra-high performance stationary phases were utilized to maximize the peak capacity and thus the resolution. But due to the shallow gradient in RPC the peak capacity was lower than on PGC. Retention times in HILIC and IP-RPC could be correlated to the monosaccharide compositions of the glycans by multiple linear regression, whereas no adequate model was obtained for PGC chromatography, indicating the significance of the three-dimensional structure of the analytes for retention in this method. Generally low correlations were observed between the chromatography methods, indicating their orthogonality. The high selectivities, as well as the commercial availability of ultra-high performance stationary phases render HILIC the chromatography method of choice for the analysis of glycans. Even though for complete characterization of complex glycan samples a combination of chromatography methods may be necessary.  相似文献   

20.
This review represents a summary of the development and application of a novel mixed-mode HPLC approach to the separation and analysis of peptides and proteins termed hydrophilic interaction/cation-exchange chromatography (HILIC/CEX). This approach combines the most advantageous aspects of two widely different separation mechanisms, i.e. a separation based on hydrophilicity/hydrophobicity differences between polypeptides overlaid on a separation based on net charge. Applications described include HILIC/CEX separations of cyclic peptides, alpha-helical peptides, random coil peptides and modified or deletion products of synthetic peptides. In addition, the excellent resolving ability of HILIC/CEX for modified histone proteins is described. This approach is shown to represent an excellent complement to RP chromatography (RPC), as well as being a potent analytical tool in its own right.  相似文献   