共查询到20条相似文献,搜索用时 187 毫秒
1.
Equations and theoretical models for MEKC separation selectivity (α(MEKC) ) were established to explain a change in separation and electrophoretic mobility order of fully charged analytes, in which α(MEKC) is related to the dimensionless values of mobility selectivity in CZE (α(CZE)) and retention selectivity (α(k)) in MEKC, and where α(CZE) and α(k) are defined as the ratio of electrophoretic mobility in CZE and the ratio of retention factor (k) in MEKC for two charged analytes, respectively. Using four alkylparabens as test analytes, excellent agreement was found between the observed α(MEKC) and the proposed α(MEKC) models of test analytes in MEKC over a wide range of SDS concentrations and values of k. For example, in comparison with CZE separation of charged analytes, MEKC separation can enhance separation selectivity up to the maximum value when the selectivity ratio (ρ) is greater than 1.0 (ρ=α(k)/α(CZE)), while lower separation selectivity is obtained with ρ<1.0 (α(CZE) >α(k) >1). 相似文献
2.
Microemulsion electrokinetic chromatography (MEEKC) and solvent modified micellar electrokinetic chromatography (MEKC) were investigated with the goal of the rapid separation of complex heroin and amphetamine samples. The rapid simultaneous separation of 17 species of heroin, amphetamine and their basic impurities and adulterants was performed within about 10 min using MEEKC for the first time, whereas solvent modified MEKCs were unable to resolve all the components. The comparisons between MEEKC and solvent modified MEKC proved internal lipophilic organic phase in microemulsions played an important role in improving the separation performance with respect to efficiency. However, the role of internal lipophilic organic phase in MEEKC was disgusted at high concentrations of cosurfactant, and the separations of MEEKC and 1-butanol modified MEKC became similar at high concentrations of 1-butanol. The evaluation of reproducibility, linearity and detection limit of optimized MEEKC method provided good results for all the analytes investigated, thus allowing its application to real controlled drug preparation analysis. 相似文献
3.
In this study, microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatography (MEKC) were compared for their abilities to separate and detect thirteen phenolic compounds (syringic acid, p-coumaric acid, vanillic acid, caffeic acid, gallic acid, 3,4-dihydroxybenzoic acid, 4-hydroxybenzoic acid, (+)-catechin, (-)-epigallocatechin, (-)-epicatechin gallate, (-)-epigallocatechin gallate, (-)-epicatechin, and (-)-gallocatechin), and two other ingredients (caffeine and theophylline) in teas and grapes. Separation of phenolic compounds was improved by changing the SDS concentration for MEEKC, but the SDS concentration rarely affected the resolution for MEKC. Organic modifier (acetonitrile or methanol) was found to markedly influence the resolution and selectivity for both MEEKC and MEKC systems. In addition, a higher voltage and a higher column temperature improved the separation efficiency without any noticeable reduction in resolution for MEEKC whereas they caused a poor resolution for the MEKC system. Although separations with baseline resolution were achieved by the optimized MEEKC and MEKC methods, the separation selectivity resulting from the proposed MEEKC method was completely different from that of MEKC. 相似文献
4.
Microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatograpy (MEKC) were compared for their abilities to separate and detect ten similar benzophenones, which are commonly used as UV filters in various plastic and cosmetic products. Sodium dodecyl sulfate (SDS) concentration and column temperature rarely affected separation resolution for MEEKC, but separation of benzophenones could be improved by changing the SDS concentration and column temperature for MEKC. Buffer pH and ethanol (organic modifier) were found to markedly influence the separation selectivity for both MEEKC and MEKC systems. In addition, a higher electric voltage improved the separation efficiency without a noticeable reduction in separation resolution for MEEKC, whereas it caused a poor separation resolution for the MEKC system. 相似文献
5.
Retention indices in micellar electrokinetic chromatography 总被引:1,自引:0,他引:1
Pim G. Muijselaar 《Journal of chromatography. A》1997,780(1-2):117-127
The use of retention indices in micellar electrokinetic chromatography (MEKC) is evaluated both from a theoretical and a practical point of view. Fundamental equations for the determination of retention indices in MEKC are described, showing that retention indices are independent of the surfactant concentration. Possibilities as well as limitations of different homologous series as reference standards are described. In addition, the practical application of retention indices for identification, investigation of solute-micelle interactions, characterization and classification of pseudo-stationary phases and determination of solute lipophilicity are discussed. 相似文献
6.
Lucangioli SE Carducci CN Scioscia SL Carlucci A Bregni C Kenndler E 《Electrophoresis》2003,24(6):984-991
Five electrokinetic chromatography systems were compared concerning retention behavior and lipophilicity. Comparison was based on capacity (retention) factors of some steroidal drugs, and on log P(OW) values derived by the aid of reference substances. In all systems the aqueous buffer consisted of phosphate (20 mM, pH 7.5). Two systems had micelles, three systems microdroplets as negatively charged pseudostationary phases. The micelles were formed by sodium dodecyl sulfate (SDS) and sodium cholate, respectively. One microemulsion consisted (as usual) from octane as oil, butanol as cosurfactant and SDS as charged tenside. Two microemulsions were made from biosurfactants (phosphatidylcholine, isopropylmyristate) to better simulate biopartitioning of the drugs. Even for noncharged analytes a change in migration sequence and thus in log P(OW) was observed for the systems consisting of the biosurfactants, compared to the others. For the former systems, log P(OW) derived from the capacity factors agree for all analytes with those obtained from calculation by computer software based on the structure of the drugs, and with experimental data directly obtained from octanol/water partitioning. 相似文献
7.
8.
The retention factor (k) and retention index (I) of homologous series compounds such as alkylbenzenes (BZ), alkylaryl ketones, alkylbenzoates, and alkylparabens in microemulsion electrokinetic chromatography (MEEKC) with suppressed electroosmosis were investigated in a wide range of SDS concentrations ([SDS]), temperatures, and concentrations of organic cosolvents (phi). Using BZ as standards, the retention indices of other homologous series compounds were determined and they were found to be independent of [SDS] and temperature, while are dependent on the types and concentrations of organic cosolvents. The retention factor linearly increases with increasing [SDS], while linearly decreases with increasing temperature. The value of log k linearly decreases with increasing phi for methanol, ethanol, or ACN, while decreases by a second-degree polynomial with increasing phi for 2-propanol. Excellent agreement was found between the observed and predicted values of log k of analytes in MEEKC at given [SDS] and phi, where the predicted values were obtained from modified equations of the linear relationship of log k as functions of [SDS], the number of carbons, and phi. Therefore, both k and I can be used for peak identification of homologous series compounds. 相似文献
9.
The retention (migration) behaviour of various barbiturates, phenylurea and triazine herbicides in micellar electrokinetic chromatography (MEKC) with uncoated fused-silica capillaries was compared with the behaviour in micellar electrokinetic chromatography with reduced electroosmotic flow (RF-MEKC) using capillaries modified with linear polyacrylamide. The error in the values of the retention factors caused by the neglection of the contribution of the electroosmotic flow in RF-MEKC was investigated and a method for correcting this error was suggested. The retention was characterised using the lipophilic and polar indices to characterise and to predict the retention as a function of the concentration of the surfactant (sodium dodecylsulphate) in the running buffer in MEKC and in RF-MEKC. Homologous series of n-alkylbenzenes and of n-alkan-2-ones were compared as the standard sets for the calibration of the retention (migration) index scale. The values of the lipophilic indices of a given solute measured in reversed-phase HPLC, MEKC and RF-MEKC are close to each other. Under ideal MEKC conditions, the values of the polarity indices are close to one for various sample solutes. However, for partially ionised compounds such as weakly acidic barbiturates, where the contribution of the electrophoretic migration is significant, the values of the polarity indices are significantly lower than one. Optimum conditions for separations of mixtures of triazine and phenylurea herbicides and of barbiturates using various techniques tested were compared. 相似文献
10.
11.
In this study, separation and determination of nine preservatives ranging from hydrophilic to hydrophobic properties, which are commonly used as additives in various pharmaceutical and cosmetic products, by micellar electrokinetic chromatograpy (MEKC) and microemulsion electrokinetic chromatography (MEEKC) were compared. The effect of temperature, buffer pH, and concentration of surfactant on separation were examined. In MEKC, the separation resolution of preservatives improved markedly by changing the sodium dodecyl sulfate concentration. Temperature and pH of running buffers were used mainly to shorten the magnitude of separation time. However, in order to detect all preservatives in a single run in a MEEKC system, a microemulsion of higher pH was needed. The separation resolution was improved dramatically by changing temperature, and a higher concentration of SDS was necessary for maintaining a stable microemulsion solution, therefore the separation of the nine preservatives in MEEKC took longer than in MEKC. An optimum MEKC method for separation of the nine preservatives was obtained within 9.0 min with a running buffer of pH 9.0 containing 20 mM SDS at 25 degrees C. A separation with baseline resolution was also obtained within 16 min using a microemulsion of pH 9.5 which composed of SDS, 1-butanol, and octane, and a shorter capillary column at 34 degrees C. Finally, the developed MEKC and MEEKC methods determined successfully preservatives in various cosmetic and pharmaceutical products. 相似文献
12.
Summary Computer-assisted procedures for the one-parameter optimization of the surfactant concentration and the concentration of urea or D-glucose as modifiers in micellar electrokinetic capillary chromatography have been developed. These procedures permit a rapid optimization of one parameter on the basis of only two experiments. Predicted values are compared to empirically obtained optimum values. The influence of the modifier concentration on the critical micelle concentration of sodium dodecyl sulfate was experimentally determined in buffers commonly employed in micellar electrokinetic chromatography. The alteration of retention factors of solutes caused by the influence of urea addition on the critical micelle concentration of sodium dodecyl sulfate was calculated under the assumption of constant distribution coefficients and compared to experimentally obtained values. It was demonstrated that the addition of urea or of D-glucose does not alter the phase ratio substantially. 相似文献
13.
The two concepts of micelle formation (pseudo-phase and mass-action) could be the basis of retention models in micellar liquid chromatography (MLC). The separation of 4-hydroxybenzoic acid esters and seven polyaromatic hydrocarbons were performed to study the repeatability of retention factor in MLC. The full two factor experimental design was used for studying the dependence of retention factor variance on mobile phase composition (sodium dodecylsulfate, 1-butanol). The experimentally observed heteroscedasticity and perturbations after linearization were taken into account by using statistical weights obtained on the basis of errors propagation law and the modeling of retention by non-weighted and weighted least squares method was performed. The mechanistical retention models based on pseudo-phase and mass-action concepts of micelle formation were compared by fitting quality and prediction capability and high robustness of bilogarithmic dependence was observed. The significance of retention factor heteroscedasticity for retention hydrophobicity relationships was shown. 相似文献
14.
New possibilities were revealed and evaluative characteristics were obtained for different versions of capillary electrophoresis
with UV detection, namely, micellar electrokinetic chromatography with normal and reversed polarity and microemulsion electrokinetic
chromatography, used for determining catechols and catecholamines in green and black tea and in urine. 相似文献
15.
The elution order of the hop α- and β-acids has been studied under different modes of electrokinetic separation. A model is advanced to explain the shorter migration times of the more hydrophobic β-acids compared to the α-acids in micellar electrokinetic chromatography (MEKC). For quality control of the bitter principles in hops, the ruggedness of electrokinetic separation could be improved by replacing MEKC by microemulsion electrokinetic chromatography (MEEKC). 相似文献
16.
A new method to influence the separation selectivity of inorganic cations in capillary electrophoresis is presented. This method combines the use of certain crown ethers to form complexes with a specific cation (changing its ionic radius/charge ratio and thereby its electrophoretic mobility) with partitioning of the crown ether/analyte complex between an aqueous phase and a pseudo-stationary phase, such as the oil droplet of a microemulsion. Several microemulsions, including uncharged oil droplets and oil droplets with different degrees of surface charge were tested to evaluate their ability to improve the separation of the selected analytes. 相似文献
17.
Fu-Ken Liu 《Journal of chromatography. A》2009,1216(12):2554-2559
In this paper, we report the use of micellar electrokinetic chromatography (MEKC) for the highly efficient preconcentration and separation of gold nanoparticles (Au NPs). We used the reversed electrode polarity stacking mode (REPSM) of the MEKC system for the on-line enhancement and separation of the Au NPs. Several parameters had dramatic effects on the systems’ performance, including the concentration of sodium dodecylsulfate (SDS) surfactant, the presence of salts in the NP solution, the pH of the running electrolyte, and the temperature of the capillary. Under the optimized conditions [buffer: SDS (70 mM) and 3-cyclohexylamino-1-propanesulfonic acid (CAPS; 10 mM) at pH 10.0; applied voltage: 20 kV; operating temperature: 25 °C; additive: sodium dihydrogenphosphate (NaH2PO4, 10 mM); REPSM strategy for sample preconcentration], the number of theoretical plates for the 5.3- and 40.1-nm-diameter Au NPs were 3000 and (an ultrahigh) 2.1 × 106, respectively; in addition, the detection sensitivities toward the Au NPs were enhanced ca. 20- and 380-fold, respectively, relative to those obtained using standard MEKC analysis conditions. Furthermore, monitoring the electropherograms using diode-array detection allowed us to identify and characterize the sizes of the separated NPs from their UV–vis spectra. Our findings suggest that MEKC is a highly efficient tool for both the preconcentration and separation of NPs. 相似文献
18.
Separations of human urine by microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic capillary chromatography (MEKC) with respect to resolution, migration times and efficiencies were optimized and compared. The optimised MEEKC and MEKC methods were simple and fast, both of which are excellent characteristics for the complex separations required in clinical and biomedical studies. However, resolution in MEKC was significantly greater than in MEEKC although migration times were 30% faster for the optimised MEEKC method. In addition, a faster analysis method (short-end injection) specifically for routine screening purposes was also investigated. With both MEEKC and MEKC modes, this provided short separations (less than 4 min for urine) with no major compromise in resolution. In conclusion, we found that MEEKC offered no real advantage over MEKC for urine analysis. 相似文献
19.
20.
M. C. Garcí a-Alvarez-Coque J. R. Torres-Lapasi J. J. Baeza-Baeza 《Journal of chromatography. A》1997,780(1-2):129-148
In micellar liquid chromatography (MLC), the resolution for a given multi-component mixture can be optimized by changing several variables, such as the concentrations of surfactant and organic modifier, the pH and temperature. However, this advantage can only be fully exploited with the development of mathematical models that describe the retention and the separation mechanisms. Several reports have appeared recently on the possibilities of accurately predicting the solute retention in MLC. Although the retention and selectivity may strongly change with varying concentrations of surfactant, organic modifier and/or pH, the observed changes are very regular, and are well described by simple models. This characteristic enables a successful prediction of retention times and compensates the negative effect of the broad and tailed chromatographic peaks obtained for some solutes when micellar eluents are used. An overview of the models proposed in the literature to describe the retention behaviour in pure micellar eluents and micellar eluents containing an organic modifier, at a fixed pH or at varying pH, is given. The equations derived permit the evaluation of the strength of micelle-solute and stationary phase-solute interactions. The prediction of the retention based on molecular properties and the use of neural networks, together with the factors affecting the prediction capability of the models (linearization of the equations, dead time, critical micellar concentration, ionic strength and temperature) are commented on. The strategies used for the optimization of resolution are also given. 相似文献