首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and selective method was developed for the preconcentration, separation, and determination of trace amounts of As(III) in an aqueous solution by solid phase extraction combined with graphite furnace atomic absorption spectrometry. Activated carbon (AC) was modified by sodium diethyldithiocarbamate (NaDDTC) and then used as a new, stable and easily prepared solid sorbent in a mini column for the extraction of As(III) in aqueous solution. Factors influencing the sorption and desorption of As(III), such as volume and concentration of eluent, sample pH, flow rate and effect of interfering ions on the recovery of As(III) have been systemically investigated. At pH 2.0 As(III) could be adsorbed quantitatively by NaDDTC‐AC, and then eluted completely with 2 mL of 3.0 mol·L?1 HNO3. The amount of eluted As(III) was measured using graphite furnace atomic absorption spectrometry. The detection limit of As(III) was 0.04 ng·mL?1 with enrichment factor of 100 and the relative standard deviation (RSD, n=8) was 1.58% at 10 ng·mL?1 level.  相似文献   

2.
Benzoylthiourea derivatives (N,N-diphenyl-N′-(3-methylbenzoyl)thiourea and diphenyl-N′-(4-methylbenzoyl)thiourea) were impregnated onto silica gel. The preconcentration of uranium(VI) from aqueous solution was investigated. Extraction conditions were optimized in batch method prior to determination by uv–visible absorption spectrometry using arsenazo(III). The optimum pH for quantitative adsorption was found as 3–7. Quantitative recovery of uranium (VI) was achieved by stripping with 0.1 mol L?1 HCl. Equilibration time was determined as 30 min for 99% sorption of U(VI). Under optimal conditions, dynamic linear range of for U(VI) was found as 0.25–10 μg mL?1. The relative standard deviation as percentage and detection limit were 5.0% (n = 10) for 10 μg mL?1 U(VI) solution and 8.7 ng mL?1, respectively. The method was employed to the preconcentration of U(VI) ions in soil and tap water samples.  相似文献   

3.
Guo  Xiaorui  Chen  Xiaohui  Cheng  Weiming  Yang  Kaiyu  Ma  Yongfen  Bi  Kaishun 《Chromatographia》2008,67(11):1007-1011

A sensitive, simple, and accurate method for determination and pharmacokinetic study of ferulic acid and isoferulic acid in rat plasma was developed using a reversed-phase column liquid chromatographic (RP-LC) method with UV detection. Sample preparations were carried out by protein precipitation with the addition of methanol, followed by evaporation to dryness. The resultant residue was then reconstituted in mobile phase and injected into a Kromasil C18 column (250 × 4.6 mm i.d. with 5 μm particle size). The mobile phase was methanol-1% formic acid (33:67, v/v). The calibration plots were linear over the range 5.780–5780 ng·mL−1 for ferulic acid and 1.740–348.0 ng·mL−1 for isoferulic acid. Mean recoveries were 85.1% and 91.1%, respectively. The relative standard deviations (RSDs) of within-day and between-day precision were not above 15% for both of the analytes. The limits of quantification were 5.780 ng·mL−1 for ferulic acid and 1.740 ng·mL−1 for isoferulic acid. This RP-LC method was used successfully in pharmacokinetic studies of ferulic acid and isoferulic acid in rat plasma after intravenous injection of Guanxinning Lyophilizer.

  相似文献   

4.
Coriolus versicolor, a wood fungus, was immobilised on Amberlite XAD-4 and used as solid-phase biosorbent for preconcentrations of rare earth elements. La(III), Th(IV), U(IV) and Ce(III) were subjected to solid-phase extraction procedure. We observed that La(III) was selectively preconcentrated, while other ions remained in solution at pH 6.0. 5.0 mL of 1.0 mol L?1 HCl was used to elaute La(III) from column. 250 mg of C. versicolor loaded on 1000 mg of XAD-4 was optimised as solid-phase matrix. Concentrations of ions in solutions were determined by inductively coupled plasma– optical emission spectrometry (ICP-OES). The calibration plot after preconcentration was linear in the range from 1.0 to 50.0 ng mL?1 for La(III). Limit of detection was found as 0.27 ng mL?1 for La(III) by SPE method. Relative standard deviation was found lower than 6.7% for 1.0 ng mL?1 of La(III) solution (n = 10). The sensitivity of ICP-OES was improved by a factor of 46.8. The applicability of the method was validated through the analysis of certified reference samples of tea (NCS ZC-73014) and spinach (NCS ZC-73013).  相似文献   

5.
This paper reports silica gel loaded with p-tert-butylcalix[8]arene as a new solid phase extractor for determination of trace level of uranium. Effective extraction conditions were optimized in column methods prior to determination by spectrophotometry using arsenazo(III). The results showed that U(VI) ions can be sorbed at pH 6 in a mini-column and quantitative recovery of U(VI) (>95–98%) was achieved by stripping 0.4 mol L−1 HCl. The sorption capacity of the functionalized sorbent is 0.072 mmol uranium(VI) g−1 modified silica gel. The relative standard deviation and detection limit were 1.2% (n = 10) for 1 μg uranium(VI) mL−1 solution and 0.038 μg L−1, respectively. The method was employed to the preconcentration of U(VI) ions from spiked ground water samples.  相似文献   

6.
Dogan-Topal  B.  Ozkan  S. A.  Uslu  B. 《Chromatographia》2007,66(1):25-30

A rapid, sensitive, and specific reverse phase high performance liquid chromatography with diode array detection procedure for the simultaneous determination of abacavir, efavirenz and valganciclovir in spiked human serum is described. Separation was performed on a 5 μm Waters Spherisorb column (250 × 4.6 mm ID) with acetonitrile: methanol:KH2PO4 (at pH 5.00) (40:20:40 v/v/v) isocratic elution at a flow rate of 1.0 mL min−1. Calibration curves were constructed in the range of 50–30,000 ng mL−1 for abacavir and efavirenz, and 10–30,000 ngmL−1 for valganciclovir in serum samples. The limit of detection and limit of quantification concentrations of the HPLC method were 3.80 and 12.68 ng mL−1 for abacavir, 2.61 and 8.69 ng mL−1 for efavirenz, 1.30 and 4.32 ng mL−1 for valganciclovir. The method has been applied, without any interference from excipients or endogenous substances, for the simultaneous determination of these three compounds in human serum.

  相似文献   

7.
An on-line solid phase micro-column extraction and determination system for trace Cd and Pb in nuclear fuel grade uranium compounds was established. The preconcentration of trace elements Cd and Pb from uranium compounds was achieved by adsorbing Cd and Pb on CL-7301 resin in hydroiodic acid media, while the uranyl ion passed through. The method coupled with flame atomic absorption spectrometry (FAAS) was applied to analysis trace Cd and Pb in real samples. The preconcentration factors obtained by this method were 320 and 180 each for Cd and Pb, respectively. Under the optimized conditions, the detection limits corresponding to three times the standard deviation of the blank were found to be 0.13 ng·mL−1 and 0.37 ng·mL−1 for Cd and Pb, respectively. The relative standard deviation (RSD) and the recoveries of standard addition (spiked with 1–5 ng of Cd and Pb) were of <5% (n = 10) and 96.2%–102.3%, respectively. Precision was also evaluated and found to be ≤4.3% (N = 11). The proposed method was successfully used for the determination of trace Cd and Pb in commercially available uranium compounds (e.g., uranyl acetate and triuranium octoxide).  相似文献   

8.
A novel sensitive and simple method for rapid and selective extraction, preconcentration and determination of uranyl as its 2,2′‐diamino‐4,4′‐bithiazole (DABTZ) complex by using octadecylsilica columns and spectrophotometry is presented. Extraction efficiency and the influence of flow rates of sample solution and eluent, pH, amount of DABTZ, type and least amount of eluent for elution of uranyl complex from columns, break‐through volume and limit of detection were evaluated. Also the effects of various cationic and anionic interferences on percent recovery of uranyl were studied. Average extraction efficiency of ca. 90% was obtained by elution of the column with minimal amount of solvent in the presence of interferences. The average preconcentration factor, 136 and a detection limit 0.32 ng·mL?1 were obtained. The method was applied to the recovery and determination of uranyl in different water samples.  相似文献   

9.
In pH 4.9 Britton-Robinson buffer solution, methotrexate (MTX) reacted with thallium(III) to form a 3∶1 chelate. This resulted in great enhancement of second-order scattering (SOS) spectra and frequency doubling scattering (FDS) spectra and appearance of new SOS and FDS spectra. Their maximum wavelengths were located at 520 and 390 nm, respectively. The increments of scattering intensities (ΔI) were directly proportional to the concentrations of MTX in the ranges of 0.022—2.0 μg•mL-1 (SOS method) and 0.008—2.5 μg•mL-1 (FDS method). The methods exhibited high sensitivities. The detection limits for MTX were 7.4 ng•mL-1 (SOS method) and 2.3 ng•mL-1 (FDS method), respectively. The optimum conditions of the reaction, the influencing factors and the effects of coexisting substances were investigated. A highly sensitive, simple and fast method for the determination of MTX has been developed. The method can be applied satisfactorily to the determination of MTX in human serum samples. In this work, the charge distribution of MTX was calculated by a CNDO quantum chemistry method. In addition, the reaction mechanism was discussed.  相似文献   

10.
Arsenazo III modified maghemite nanoparticles (A-MMNPs) was used for removing and preconcentration of U(VI) from aqueous samples. The effects of contact time, amount of adsorbent, pH and competitive ions was investigated. The experimental results were fitted to the Langmuir adsorption model in the studied concentration range of uranium (1.0 × 10?4–1.0 × 10?2 mol L?1). According to the results obtained by Langmuir equation, the maximum adsorption capacity for the adsorption of U(VI) on A-MMNPs was 285 mg g?1 at pH 7. The adsorbed uranium on the A-MMNPs was then desorbed by 0.5 mol L?1 NaOH solution and determined spectrophotometrically. A preconcentration factor of 400 was achieved in this method. The calibration graph was linear in the range 0.04–2.4 ng mL?1 (1.0 × 10?10–1.0 × 10?8 mol L?1) of U(VI) with a correlation coefficient of 0.997. The detection limit of the method for determination of U(VI) was 0.01 ng mL?1 and the relative standard deviation (R.S.D.) for the determination of 1.43 and 2.38 ng mL?1 of U(VI) was 3.62% and 1.17% (n = 5), respectively. The method was applied to the determination of U(VI) in water samples.  相似文献   

11.
Zhang  Jing  Sun  Aimin  Yang  Yi  Hu  Jielan  Wei  Ling  Gao  Bo  Ding  Xueqin  Qin  Yang  Sun  Chengjun 《Chromatographia》2016,79(23):1649-1658

In this study, a method of field-amplified sample injection coupled with capillary zone electrophoresis with ultraviolet detection was established for evaluation of DNA methylation and hydroxymethylation levels in biological materials. By modifying an existing method, the separation of cytosine (C), 5-methylcytosine (5-mC) and 5-hydroxymethylcytosine (5-hmC) was performed on an uncoated capillary column (40 cm × 75 μm I.D.) using 300 mmol L−1 tris solution (pH 2.90) as running buffer and detected at 280 nm. The detection limits (S/N = 3) of the method were 0.004 ng mL−1 for cytosine (C), 0.01 ng mL−1 for 5-methylcytosine (5-mC), and 0.02 ng mL−1 for 5-hydroxymethylcytosine (5-hmC). The proposed method has been successfully applied to the evaluation of DNA methylation and hydroxymethylation levels of blood samples from 15 hepatocellular carcinoma patients and 5 liver cirrhosis patients and liver tissues from 50 pairs of tumor and matched tumor-adjacent samples.

  相似文献   

12.
Singh BN  Maiti B 《Talanta》2006,69(2):393-396
Amberlite XAD-4 adsorber resin was modified with 8-hydroxy quinoline (Oxine) by equilibrating with methanol solution of the reagent and the modified resin was used as a support material for the solid phase extraction and preconcentration of UO22+ from aqueous solution at pH between 4 and 5.5. Ten micrograms of uranium from 300 ml of aqueous phase could be quantitatively extracted in to 1 g of the modified resin giving an enrichment of 200. Uranium collected in the column could be eluted out with methanol-HCl mixture and determined spectrophotometrically using arsenazo(III) as the chromogenic reagent. The preconcentration could be made selective to uranium by using EDTA as a masking agent for transition metal ions and Th(IV).  相似文献   

13.
The interaction between anionic surfactants (AS) and 1‐hexadecyl‐3‐methylimidazolium bromide [C16mim]Br was studied by using resonance light scattering (RLS) technique, UV‐Vis spectrophotometry and fluorometric methods. In Britton Robinson (BR) buffer (pH 6.0), [C16mim]Br reacted with AS to form supermolecular complex which resulted in enhancement in RLS intensity. Their maximum RLS wavelengths were all at 390 nm. Some important interacting experimental variables, such as the solution acidity, [C16mim]Br concentration, salt effect and addition order of the reagents, were investigated and optimized. Under the optimum conditions, quantitative determination ranges were 0.001–7 μg·mL?1 for dodecyl sodium sulfate (SDS), 0.001–6 μg·mL?1 for sodium dodecylbenzene sulfonate (SDBS) and 0.005–7 μg·mL?1 for sodium lauryl sulfonate (SLS), respectively, while the detection limits were 1.3 ng·mL?1 for SDS, 1.0 ng·mL?1 for SDBS and 5.1 ng·mL?1 for SLS, respectively. Based on the ion‐association reaction, a highly sensitive, simple and rapid method has been established for the determination of AS.  相似文献   

14.
Du  Kehe  Wu  Caisheng  Ding  Chunguang  Zhao  Shanlin  Qin  Hailin  Zhang  Jinlan 《Chromatographia》2009,69(11):1259-1266

A rapid and specific high-performance liquid chromatographic method coupled with electrospray ionization mass spectrometric detection has been developed and validated for identification and quantification of wogonin and oroxylin A in rat plasma. Wogonin, oroxylin A, and diazepam (internal standard) were extracted from plasma samples by liquid–liquid extraction with ethyl acetate. Chromatographic separation was achieved on a C18 column with acetonitrile–0.6% aqueous formic acid 35:65 (v/v) as mobile phase at a flow rate of 0.2 mL min−1. Detection was performed with a single-quadrupole mass spectrometer in selected-ion-monitoring (SIM) mode. Linearity was good within the concentration range 14.4–360 ng mL−1 for wogonin and 10.8–271 ng mL−1 for oroxylin A; the correlation coefficients (r 2) were 0.9999. The intra-day and inter-day precision, as RSD, was below 12.4%, and accuracy ranged from 81.1 to 111.9%. The lower limit of quantification was 14.4 ng mL−1 for wogonin and 10.8 ng mL−1 for oroxylin A. This method was successfully used in the first pharmacokinetic study of wogonin and oroxylin A in rat plasma after oral administration of the active fraction from Xiao-xu-ming decoction.

  相似文献   

15.
Zhang  Xianhua  Zhao  Xia  Zhang  Chao  Yang  Li  Xiong  Xin  Zhou  Yong  Yang  Yiheng  Duan  Jingli 《Chromatographia》2010,71(11):1015-1023

A sensitive and specific LC–MS-MS method is described for the simultaneous quantification of risperidone and 9-hydroxyrisperidone in human plasma. After extraction with tert-butyl methyl ether, plasma samples were separated on an Atlantis HILIC Silica C18 column (4.6 × 150 mm, 5 μm)with a mobile phase of ammonium formate buffer (10 mM, pH 4.0)/acetonitrile (40/60, v/v). Detection was by MS-MS. The method was fully validated according to the accuracy profile theory. It is based on β-expectation tolerance interval for the total measurement error which includes trueness and intermediate precision. The measurement uncertainty derived from β-expectation tolerance interval was estimated at each of the validation standards. The linearity fitted well over the range of 0.11–26.75 ng mL−1 for risperidone with an LLOQ of 0.11 ng mL−1, and for 9-hydroxyrisperidone, at a range of 0.15–37.8 ng mL−1 with an LLOQ of 0.15 ng mL−1. The intra- and inter-batch precision of risperidone were <5.71 and 8.22%, respectively. For 9-hydroxyrisperidone, the data were 5.78 and 6.48%. The recoveries were 88.78% (risperidone) and 70.35% (9-hydroxyrisperidone). The developed method was applied to a pharmacokinetic study of risperidone.

  相似文献   

16.
Ate&#;  Z.  &#;zden  T.  &#;zilhan  S.  Eren  S. 《Chromatographia》2007,66(1):119-122

A simple, rapid, sensitive and selective method for the analysis of indapamide in human plasma, utilizing ultra performance liquid chromatography (UPLC), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and the internal standard, sulfamethazine, were isolated from plasma samples by liquid–liquid extraction with diethyl ether. Separation was performed with an Acquity C18 column. The gradient composition of mobile phase was composed of acetonitrile and sodium dihydrogenphosphate buffer (adjusted to pH 3.33 with 85% o-phosphoric acid) at a flow rate of 0.5 mL min−1. The assay exhibited a linear dynamic range of 1–100 ng mL−1 for indapamide in human plasma. The limit of quantification (LOQ) was 1 ng mL−1. The method was successfully applied to the pharmacokinetic and bioequivalence studies of indapamide formulations.

  相似文献   

17.
Dogan-Topal  B.  Uslu  B.  Ozkan  S. A. 《Chromatographia》2007,66(1):97-101

This paper describes the validation of an isocratic high-performance liquid chromatographic method for the assay of valganciclovir in raw materials, tablets and human serum samples. Valganciclovir and fluvastatin (internal standard) were well separated using a reversed phase column and a mobile phase consisting of a mixture of acetonitrile:methanol:KH2PO4 (0.02 M) (40:20:40; v/v/v) (at pH 5.0). The mobile phase was pumped at 1.0 mL min−1 flow rate and valganciclovir was detected by diode-array detection at 255 nm. The retention times for valganciclovir and fluvastatin were 3.41 and 5.60 min, respectively. A linear response (r > 0.999) was observed in the range of 10–30,000 ng mL−1 in mobile phase and serum. The limit of detection and limit of quantification were found as 2.95 and 9.82 ng mL−1 in mobile phase and 1.73 and 5.77 ng mL−1 in human serum samples, respectively. Validation parameters as precision, accuracy, selectivity, reproducibility and system suitability tests were also determined. The method can be used for valganciclovir assay of tablets and human serum samples as the method separates valganciclovir from tablet excipients and endogenous substances.

  相似文献   

18.
Qiaozhen Guo  Zhenxia Du 《中国化学》2011,29(9):1922-1926
A simultaneous method was successfully established and validated for the separation and determination of buprenorphine (BP), its primary metabolite, nor‐buprenorphine (NBP) and a proposed co‐formulate, naloxone (NLX) in human plasma. The method used buprenorphine‐d4 (BP‐D4), nor‐buprenorphine‐d3 (NBP‐D3), naltrexone (NTX) as internal standards (ISs). 100 μL of plasma sample fortified with the ISs was cleaned up by solid‐phase extraction (SPE), and was then separated on a Waters AcquityTM BEH C18 column with gradient elution using methanol and water (containing 0.2% formic) at a flow rate of 0.25 mL·min−1. The mass spectrometer was used for detection and was operated in the positive electrospray ionization with multiple reaction monitoring (MRM) mode. The three compounds were effectively separated in 5 min. The linear ranges of the compounds were 0.1–25, 0.25–25 and 0.05–25 ng·mL−1 for BP, NBP and NLX, respectively, with r≧0.9935. The method had high sensitivity (the limits of detection were 0.02, 0.1 and 0.01 ng·mL−1 for BP, NBP and NLX, respectively) and high recoveries (≧97.6%). The result was shown to be linear and satisfactorily met current acceptance criteria for validation of bioanalytical method: intra and inter assay precisions within the required limits of ≦25% RSD. The LOQs fulfilled the LOQ requirements: precision≦25% RSD, and was fully validated according to the State Food and Drug Administration (SFDA) regulations. The results demonstrated that ultra‐high performance liquid chromatography‐tandem mass spectrometer (UPLC‐MS/MS) with SPE was a powerful detection tool and contributed to pharmaceutical analysis in biological matrices.  相似文献   

19.
Dincel  A.  Basci  N. E.  Atilla  H.  Bozkurt  A. 《Chromatographia》2007,66(1):51-56

A sensitive high performance liquid chromatographic method has been developed and validated for the determination of proparacaine in human aqueous humour. The procedure involved extraction of proparacaine from aqueous humour with cyclohexane. The separation was achieved using a Bondesil C8 (250 × 4.6 mm i.d., particle size 5 μm) analytical column with a mobile phase consisted of acetonitrile and sodium dihydrogen phosphate (pH 3.0, 20 mM) (30:70, v/v). Proparacaine and lidocaine (internal standard, IS) detection was performed by UV–Vis detector at 220 nm. The retention times for proparacaine and IS were 12.01 and 5.58 min, respectively. HPLC–UV–Vis method was linear in the range of 75–4,000 ng mL−1. The limit of detection (LOD) was 25 ng mL−1 and the limit of quantification (LOQ) of proparacaine was found to be 75 ng mL−1 (RSD ≤ 15%, = 6). In intra- and inter-day precision and accuracy analysis, the relative standard deviation was found to be in the range of 0.96 and 7.98%, the bias values were 0.64 and 3.33%. Recovery of proparacaine from human aqueous humour was 99.98% at 500 ng mL−1. Proparacaine solutions were stable at least 6 months at +4 and −20 °C. Proparacaine levels of aqueous humour in fifteen volunteers’ were in the range of 80.21 and 459.00 ng mL−1. According to system suitability tests and Shewhart’s quality control charts the proparacaine responses were in the acceptance ranges. Developed method was providing a sufficient quality at least over 3 months for determination of proparacaine in human aqueous humour.

  相似文献   

20.
《Analytical letters》2012,45(16):2655-2664
Sample preparation technique based on an organic filter membrane (pH-resolved filter membrane microextraction) (pH-RFMME) was developed, coupled with high-performance liquid chromatography, and used to determine protoberberine alkaloids (jatrorrhizine, epiberberine, coptisine, palmatine, and berberine) in Coptis chinensis at different pH values through a one-step procedure. This green procedure provides a desirable sample pretreatment technology. The main variables affecting the extraction such as filter membrane area (or volumes of extraction solvents), sample pH, eluent pH, ionic strength, extraction stirring rate, extraction time, and sample volume were optimized. Under the optimized conditions, the enrichment factors of the analytes were 40.4–52.0, the linear ranges were 3.2–6250 ng · mL?1 for jatrorrhizine and epiberberine, 6.0–12000 ng · mL?1 for coptisine, 1.8–3600 ng · mL?1 for palmatine, and 18.8–18800 ng · mL?1 for berberine, with r 2 ≥ 0.9945. The limits of detection were less than 0.3 ng · mL?1. Satisfactory recoveries (84.8%–115.5%) and precision (1.8%–10.0%) were also achieved. These results confirmed that pH-RFMME is a simple, rapid, practical, and environmentally friendly method to isolate analytes that exhibit significant differences in acidity or alkalinity from complex samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号