首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
The application of semipermeable membrane devices (SPMDs) has been evaluated as a passive sampler for the collection of multiresidue pesticides in continental waters. Seven chlorinated, five organophosphorus, six carbamate, nine pyrethroid and ten other pesticides were tested in order to estimate which compounds can be retained with these devices. The effect of water parameters, such as temperature, pH, ionic strength and organic matter content, were evaluated for their effect on the retention of the pesticides by the SPMDs. Studies of uptake from water were performed in a glass beaker containing 2 L distilled water spiked with 50 ng L−1 of each pesticide investigated. A SPMD was put in the beaker, under turbulent conditions, and analysed after 2 days’ extraction. The contents of each SPMD were microwave-assisted-extracted twice with 30 mL hexane–acetone, to 90 °C for 10 min, and this was followed by a cleanup based on acetonitrile partitioning and solid-phase extraction. Gas chromatography with tandem mass spectrometry detection was employed for determination of pesticides, and provided low limits of detection from 0.5 to 7 ng per SPMD. Higher absorption rates were observed for pyrethroid, organophosphorus and chlorinated compounds than for carbamates. Pesticide uptake rates were independent of the water composition and decreased at low temperature. Electronic supplementary material The online version of this article contains supplementary material, which is available to authorized users.  相似文献   

2.
Microwave-assisted extraction (MAE) has been evaluated as an alternative to dialysis for extraction of some water-borne hydrophobic contaminants sampled by semi-permeable membrane devices (SPMDs). Seven organochlorine pesticides (OCPs), 11 polychlorinated biphenyls (PCBs) and 13 polycyclic aromatic hydrocarbons (PAHs) were accumulated in SPMDs at nanogram levels and extracted with three 3-min irradiation cycles with 33 mL of a solvent mixture hexane–water (10:1,v/v) in each cycle. The developed MAE method gave for all analytes investigated statistically comparable extraction yields with those found by dialysis carried out with a total volume of 250 mL hexane for 48 h at room temperature. The recoveries of all the targeted contaminants were in the range of 65–105% with variation coefficients not exceeding 19%. The applicability of the MAE extraction was tested in field SPMDs samples deployed for 15 days in a sewage-treatment process. Our results show that MAE provides a remarkable reduction of time and solvent volume when used as an extraction method in the analysis of SPMDs.  相似文献   

3.
A new analytical strategy to screen for endocrine-disrupting chemicals (EDCs) in environmental matrices is presented. The strategy uses solid-phase extraction followed by large volume injection and capillary gas chromatography coupled to mass spectrometry combined with retention time locking libraries (SPE-LVI-GC-MS-RTL). Characterization of the proposed methodology (SPE-LVI-GC-MS) for selected classes of EDCs enabled high reproducibility and robustness at the ultratrace level. The RTL databases used allowed hundreds of non-target semivolatiles (i.e., pesticides, polycyclic aromatic hydrocarbons, polychlorinated biphenyls and other classes of suspected EDCs from a great number of unknown environmental matrices) to be simultaneously screened for in an easy, fast and remarkable manner. The application of the proposed methodology to real environmental samples demonstrated its remarkable selectivity and sensitivity at the ultratrace level. Screening assessments performed on water and sediment matrices from eight Portuguese estuaries and coastal waters identified EDC "hotspots." These EDCs mainly come from agricultural and a wide variety of industrial sources, and include pesticides and pesticide metabolites, phenolic derivatives and polycyclic aromatic hydrocarbons, which are included in the lists of priority substances published by international environmental agencies. The estuaries that contained relatively high levels of pesticides were Guadiana, Sado and Mondego, while Minho, Douro and Formosa showed enhanced levels of phenolic derivatives. Dibutyltin and tributyltin, selected as target compounds to be monitored by SPE-LVI-GC-MS in the selected ion monitoring mode, were shown to be widespread contaminants at trace levels in almost all of the sediment matrices assessed. The reliability of the proposed methodology undoubtedly makes it a valuable tool that could replace other analytical strategies currently used to screen for EDCs present in the environment at ultratrace levels.  相似文献   

4.
The ability to measure environmental contaminants in biological tissues and fluids is important in the characterization of exposure. However, the analysis of certain contaminants in these matrices presents significant challenges. Perchlorate (ClO4) has emerged as a potential contaminant of concern primarily in drinking water and also in contaminated food. Significant advances have been made in the analysis of perchlorate in environmental matrices (water, soil) by ion chromatography (IC). In contrast, the analysis of perchlorate in extracts of biological tissues and fluids (vegetation, organs, milk, blood, urine, etc.) presents several challenges including small sample sizes, extracts with high matrix conductivity, and co-elution of other ions during IC analysis. To be able to detect low concentrations of perchlorate in biological samples, interferences must be removed or minimized, such as through the use of preparative chromatography cleanup techniques and/or alternative analytical methods less susceptible to common interferences (preconcentration or mass spectrometric detection). We present discussion and examples of the challenges encountered in the analysis of tissue extracts and fluids for perchlorate by IC and how some of those analytical challenges have been overcome.  相似文献   

5.
Vegetation (and pine needles in particular) has been widely used as an alternative to other conventional sampling devices to assess the atmospheric presence of semi-volatile organic contaminants (SVOCs). While most analytical procedures developed focus only on one or two chemical classes, this this work intends to establish a multi-component protocol to quantify brominated flame-retardants (BFRs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), polynuclear aromatic hydrocarbons (PAHs) and one class of contaminant of emerging concern, the synthetic musks fragrances (SMCs). Pine needles extracts were obtained by ultrasonic solvents extraction (USE), and different cleanup approaches using solid-phase extraction (SPE) employing combinations of sorbents and solvents as well as gel permeation chromatography (GPC) were tested. SPE with alumina followed by GCP yielded the best results, with average recoveries over 80%.  相似文献   

6.
Semipermeable membrane devices (SPMD) represent a passive sampling technology that is becoming widely used for monitoring of surface waters pollution. While "classic" procedures employ dialysis to recover target compounds from exposed SPMDs, in the present study analytes were isolated from cut membrane together with sequestering medium (triolein) using hexane as an extraction solvent. This approach allowed us to reduce the time needed for accomplishment of isolation step from 48 h to only 1 h. Automated gel permeation chromatography (GPC) clean-up is employed in the following step to separate triolein from analytes fraction. Musk compounds (MCs), polychlorinated biphenyls (PCBs), brominated flame retardants (BFRs) and several other persistent organochlorine compounds (OCs) were determined in the respective fraction by GC method employing selective detectors (MSD, ECD). As shown in a series of analyses of SPMDs deployed in various aquatic ecosystems, high recoveries and good repeatability of results together with a possibility to obtain the information on the pollution of sampling site at the day of sample arrival to laboratory make this newly implemented procedure an interesting alternative to time consuming dialysis.  相似文献   

7.
For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs). Electronic supplementary material Supplementary material is available in the online version of this article at and is accessible for authorized users.  相似文献   

8.
张一清  郭珊珊  孙倩 《色谱》2021,39(8):827-834
有机新污染物是一类在先进分析技术帮助下新鉴定的、现有法规未管制的、人为源的有机污染物.有机新污染物主要包括药品与个人护理、农药、全氟化合物、内分泌干扰物等,其会产生内分泌干扰效应、诱发抗性基因传播,还对人类和野生生物的生存与发展构成潜在威胁,因此检测环境样品中的有机新污染物浓度对生态环境和人体健康具有重大意义.由于环境...  相似文献   

9.
It has been evaluated the use of semipermeable membrane devices (SPMDs) as passive samplers of organophosphorus pesticides from air, in order to determine the contamination of working environments. Additionally, the use of SPMDs as portable samplers has been also considered. The analytical methodology for the determination of diazinon, chlorpyrifos-methyl, pirimiphos-methyl, chlorpyrifos and fenthion in SPMDs exposed to contaminated air was based on microwave-assisted extraction and gas chromatography with mass spectrometry determination. Limit of detection (LOD) values from 2 to 4 ng SPMD−1 and repeatability from 2 to 7% were obtained by using the aforementioned methodology. Theoretical calculated sampling rates were employed for the estimation of the pesticide concentration in air, by using the pesticide mass retained in the deployed SPMD. The obtained LOD values, for a sampling time of 7 days, were from 1 to 2 ng m−3. The evaluation of the air quality of a pesticide laboratory with an intensive use of diazinon and chlorpyrifos has been made in order to check the operation safety conditions.  相似文献   

10.
Aspects of the International Atomic Energy Agency (IAEA) Analytical Quality Control Services (AQCS) for marine environmental studies are discussed, focusing on recent laboratory performance studies (LPS) and the production of reference materials for trace metals and organic compounds in various marine matrices. The IAEA has organized seventeen global interlaboratory studies for a range of organic contaminants. Of note has been the inclusion of numerous polychlorinated biphenyl congeners (PCBs) and some sterols of anthropogenic origin. Concurrently, there have been eleven worldwide intercomparison exercises for trace metals in the marine environment, most of which included methylmercury. Although such interlaboratory studies can help improve performance in individual laboratories and regional laboratory networks, the results reveal that problems remain in the determination of some metals and many organic contaminants.  相似文献   

11.
Emerging contaminants are a broad category of chemicals, previously unknown or unrecognized as being of concern, but which, because of their potential health effects associated with human exposure, are under increasing scrutiny. To accurately measure their levels in biological matrices, specific and sensitive analytical methods have recently been developed. We have reviewed here the methods used for analysis of selected emerging organic contaminants, for example metabolites of organophosphate triesters, metabolites of new phthalates or phthalate substitutes, perchlorate, organic UV filters, and polycyclic siloxanes, in human matrices. Although the use of new techniques and approaches has been emphasized, we also acknowledge methods previously used for other contaminants and adapted for the emerging contaminants listed above. In all cases, chromatography and mass spectrometry were the techniques of choice, because of their selectivity and sensitivity for measurements at ng?g?1 levels. Critical issues and challenges have been discussed, together with recommendations for further improvement in particular cases (e.g. metabolites of phthalates or their substitutes). In particular, the use of labeled internal standards, the availability of certified reference materials, and the need for interlaboratory comparison exercises are key aspects of further development of this field of research.
Figure
Humans are daily exposed to a cocktail of chemicals, including new compounds  相似文献   

12.
This review shows the state of the art, from 2000 to nowadays, of the use of semipermeable membrane devices (SPMDs) for monitoring persistent organic pollutants in both, air and aquatic environments. Since their first use in 1990, SPMDs have been employed for many environmental purposes, like air and water pollution monitoring. We have focussed the study in three subjects: (i) novel compounds accumulated by SPMDs, (ii) modifications of SPMDs to improve their specific uptake properties and (iii) alternatives in sample pre-treatment for the determination of pollutants accumulated in SPMDs.  相似文献   

13.
Headspace microextraction procedures such as solid-phase microextraction (SPME) and single drop microextraction (SDME) or liquid-phase microextraction (LPME) are increasingly used for the extraction of environmental organic pollutants from a variety of aqueous, viscous, semisolid and solid environmental and biological matrices. In this article, recent analytical applications of these methodologies when used as an isolation and trace enrichment step prior to the analysis of organic pollutants (pesticides, polycyclic aromatic hydrocarbons, polychlorinated compounds, organotin compounds, phenolic derivatives, aromatic amines, phthalates, etc.) by gas and liquid chromatography are reviewed. The applicability and inherent limitations of headspace microextraction are also discussed. The future direction of research in this field and general trends toward commercial applications are considered.  相似文献   

14.
In recent years there has been much progress in the miniaturization of sample treatment approaches for the analysis of organic contaminants. Whilst much focus has been given to analysis of liquid matrices (e.g., water, biological fluids), equivalent approaches for lipid rich biota samples have seen significantly less progress. This is especially the case for samples of very small organisms commonly employed as standard test species in ecotoxicity studies. Typically, the extractable biotic sample size available for body residue analysis is very small and the total pollutant accumulation can vary significantly between species types according to factors such as organism size, lipid content and exposure conditions. Depending on the physical and chemical characteristics of the analyte(s) in question, extraction and purification, especially from more complex matrices, appears to be one of the main bottlenecks in achieving their quantification. The current article presents a review of the available micro-extraction methods for small marine biota samples, focusing on environmentally important organic pollutants such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and pesticides.  相似文献   

15.
一种新的有机污染物采样装置   总被引:2,自引:0,他引:2  
介绍了一种由类脂物和半透膜组成的采样装置,该装置可模拟生物监测可被生物订的有机污染物。将其用于监测大气、水体、沉积物中的多氯联苯(PCBs)、有机氯农药(OCP)和多环芳烃(PAHs)时,结果满意。  相似文献   

16.
The efficiency of treatment processes forboth municipal and industrial wastewater (treatment plant-Ostrava, Czech Republic) focused on persistent organic pollutants (POPs) was assessed. Semipermeable membrane devices (SPMDs) as a sampling system were applied. Exposed SPMDs were analyzed both for chemical contaminants of POPs and toxicity response. The chemical analyses of PAHs were made by HPLC-FLD, PCDD/Fs and PCBs were analysed by GC/MS/MS on GCQ or PolarisQ (Thermoquest). Ecotoxicity data on chlorococcal alga Desmodesmus subspicatus (Scenedesmus subspicatus) and luminescent bacteria Vibrio fischeri are presented here. All toxicity data as effective volume Vtox are expressed. The results show good treatment ability of the treatment plant and proved used system as an appropriate tool for efficiency assessment of treatment and/or decontamination processes.  相似文献   

17.
超临界流体萃取在环境分析中的应用   总被引:18,自引:0,他引:18  
游静  王国俊  俞惟乐 《色谱》1999,17(1):30-34
按基体的不同形态综述了1993年以来超临界流体萃取在痕量环境污染物分析中的最新进展情况,55篇。常见萃取分析的有机污染物主要包括多环芳烃、多氯联苯、二咕恶咕英、石油烃类、酚类化合物、农药和除草剂残留、金属离子和表面活性剂等。  相似文献   

18.
Tong L  Yang J  Wu S 《色谱》2011,29(3):228-233
根据植物样品中的主要干扰物质,建立了用于气相色谱(GC)和气相色谱-质谱联用(GC-MS)测定植物样品中含氯有机污染物残留的样品前处理方法,有效提高了对植物样品中有机氯农药及多氯联苯检测的灵敏度。采用均质提取法对样品进行提取,考察了凝胶渗透色谱(GPC)和固相萃取(SPE)对提取液的净化效果。结果发现,采用GC测定目标物时,提取液需经GPC和SPE两次净化;而采用GC-MS测定目标物时,仅用SPE一次净化即可。该方法快速、经济、灵敏,适合多种植物样品中有机污染物残留分析的样品前处理要求。  相似文献   

19.
A new method for rapid determination of 73 target organic environmental contaminants including 18 polychlorinated biphenyls, 16 organochlorinated pesticides, 14 brominated flame retardants and 25 polycyclic aromatic hydrocarbons in fish and fish feed using gas chromatography coupled with triple quadrupole tandem mass spectrometry (GC–MS/MS) was developed and validated. GC–MS/MS in electron ionization mode was shown to be a powerful tool for the (ultra)trace analysis of multiclass environmental contaminants in complex matrices, providing measurements with high selectivity and sensitivity. Another positive aspect characterizing the newly developed method is a substantial simplification of the sample preparation, which was achieved by an ethyl acetate QuEChERS (quick, easy, cheap, effective, rugged and safe) based extraction followed by silica minicolumn clean-up. With use of this sample preparation approach the sample laboratory throughput was increased not only because six samples may be prepared in approximately 1 h, but also because all the above-mentioned groups of contaminants can be determined in a single GC–MS/MS run. Under the optimized conditions, the recoveries of all target analytes in both matrices were within the range from 70 to 120 % and the repeatabilities were 20 % or less. The method quantification limits were in the range from 0.005 to 1 μg kg–1 and from 0.05 to 10 μg kg–1 for fish muscle tissue and fish feed, respectively. The developed method was successfully applied to the determination of halogenated persistent organic pollutants and polycyclic aromatic hydrocarbons in fish and fish feed samples.  相似文献   

20.
Potential difficulties associated with background silver salt clusters during matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) of nonpolar polymers are reported. Silver salt cluster ions were observed from m/z 1500 to 7000 when acidic, polar matrices, such as 2,5-dihydroxybenzoic acid (DHB), all-trans-retinoic acid (RTA) or 2-(4-hydroxyphenylazo)benzoic acid (HABA), were used for the analysis of nonpolar polymers. These background signals could be greatly reduced or eliminated by the use of nonpolar matrices such as anthracene or pyrene. Representative examples of these background interferences are demonstrated during the analysis of low molecular weight nonpolar polymers including polybutadiene and polystyrene. Nonpolar polymers analyzed with acidic, polar matrices (e.g., RTA) and silver cationization reagents can yield lower quality mass spectral results when interferences due to silver clusters are present. Replacing the polar matrices with nonpolar matrices or the silver salts with copper salts substantially improved the quality of the analytical results. In addition, it was found that silver contamination cannot be completely removed from standard stainless steel sample plates, although the presence of silver contamination was greatly reduced after thorough cleaning of the sample plate with aluminum oxide grit. Carry-over silver may cationize polymer samples and complicate the interpretation of data obtained using nonpolar matrices in the absence of added cationization reagents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏