首页 | 本学科首页   官方微博 | 高级检索  
     

PVC膜离子选择电极检测下限的优化
引用本文:黄美荣,丁永波,李新贵. PVC膜离子选择电极检测下限的优化[J]. 化学进展, 2012, 24(8): 1560-1571
作者姓名:黄美荣  丁永波  李新贵
作者单位:同济大学材料科学与工程学院 先进土木工程材料教育部重点实验室 材料化学研究所 上海 200092
基金项目:国家自然科学基金项目(No.20974080)资助
摘    要:价格低廉、携带方便、适用浓度宽、操作简单快捷、能耗低的离子选择电极在医院、分析实验室、野外等领域得到了越来越广泛的应用。尽管如此,由于PVC膜中存在的离子流严重破坏了更低检测下限的获取,限制了离子选择电极的进一步发展。因此,本文从减小甚至消除PVC膜中存在的离子流角度出发,系统论述了优化PVC膜离子选择电极检测下限的原理和优良策略,根据收集归纳的大量数据定量阐述传感膜组成的优化、电极组装和调制、应用旋转电极以及电流极化处理等对检测下限的优化提升作用,进一步总结出各种方法的改善规律,分析它们的优势和面临的问题。提出在PVC铸膜液中要突破传统配方,减小增塑剂和离子交换剂用量,以抑制传感膜两侧的离子流,同时外加电流补偿处理等也是降低电极检测下限的有效方法,对检测下限的改善最好的可降低5个数量级。这一总结为PVC膜离子选择电极的高性能化明确了研究方向。

关 键 词:PVC传感膜  离子选择电极  传感器  检测下限  优化  
收稿时间:2011-11-01
修稿时间:2012-02-01

Improvement of Lower Detection Limit of Ion-Selective Electrodes Based on PVC Membrane
Huang Meirong Ding Yongbo Li Xingui. Improvement of Lower Detection Limit of Ion-Selective Electrodes Based on PVC Membrane[J]. Progress in Chemistry, 2012, 24(8): 1560-1571
Authors:Huang Meirong Ding Yongbo Li Xingui
Affiliation:Institute of Materials Chemistry, Key Laboratory of Advanced Civil Engineering Materials of the Ministry of Education, College of Materials Science and Engineering, Tongji University, Shanghai 200092, China
Abstract:Ion-selective electrodes(ISEs) based on polymeric membranes are characterized by small size,portability,low-energy consumption,and low cost,which are attractive features concerning practical applications.However,the lower detection limit is biased by the ion flux through PVC membrane,which limits the further development of ion-selective electrode.Therefore,the principles and attractive strategies to suppress such an ion flux to improve the lower detection limit of PVC membrane-based ion-selective electrodes are elaborated in this article.According to large amounts of data collected,the improvement of the detection limit via optimization of sensing membrane composition,electrode assembly and conditioning,electrode rotation,as well as current-polarized treatment,is quantitatively discussed.Furthermore,the modification regulations for expanding the lower detection limit are systematically summarized.The significant superiority and problems are analyzed.It is pointed out that we have to break the conventional PVC composition formulation via reducing the dosages of plasticizer and ion exchanger in order to largely depress the transmembrane ion flux.External-current application to the electrode is also an effective approach,among which,the best improvement for the lower detection limit can reach up to 5 orders of magnitude.This review reveals the future direction for developing the PVC membrane-based ion-selective electrodes with high performance.
Keywords:PVC sensing membrane  ion-selective electrode  sensor  lower detection limit  improvement
本文献已被 CNKI 等数据库收录!
点击此处可从《化学进展》浏览原始摘要信息
点击此处可从《化学进展》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏