首页 | 本学科首页   官方微博 | 高级检索  
     


Development and validation of a sensitive UHPLC‐MS/MS method for the simultaneous analysis of tramadol,dextromethorphan chlorpheniramine and their major metabolites in human plasma in forensic context: application to pharmacokinetics
Authors:Hala M. Heneedak  Ismail Salama  Samia Mostafa  Ehab EL‐Kady  Mohamed El‐Sadek
Affiliation:1. Analytical Toxicology Laboratory, Forensic Medicine Authority, Ismailia, Egypt;2. Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Suez Canal University, Ismailia, Egypt;3. Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Cairo University, Cairo, Egypt;4. Department of Medicinal Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig, Egypt
Abstract:The prerequisites for forensic confirmatory analysis by LC/MS/MS with respect to European Union guidelines are chromatographic separation, a minimum number of two MS/MS transitions to obtain the required identification points and predefined thresholds for the variability of the relative intensities of the MS/MS transitions (MRM transitions) in samples and reference standards. In the present study, a fast, sensitive and robust method to quantify tramadol, chlorpheniramine, dextromethorphan and their major metabolites, O‐desmethyltramadol, dsmethyl‐chlorpheniramine and dextrophan, respectively, in human plasma using ibuprofen as internal standard (IS) is described. The analytes and the IS were extracted from plasma by a liquid–liquid extraction method using ethyl acetate–diethyl‐ether (1:1). Extracted samples were analyzed by ultra‐high‐performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry (UHPLC‐ESI‐MS/MS). Chromatographic separation was performed by pumping the mobile phase containing acetonitrile, water and formic acid (89.2:11.7:0.1) for 2.0 min at a flow rate of 0.25 μL/min into a Hypersil‐Gold C18 column, 20 × 2.0 mm (1.9 µm) from Thermoscientific, New York, USA. The calibration curve was linear for the six analytes. The intraday precision (RSD) and accuracy (RE) of the method were 3–9.8 and ?1.7–4.5%, respectively. The analytical procedure herein described was used to assess the pharmacokinetics of the analytes in 24 healthy volunteers after a single oral dose containing 50 mg of tramadol hydrochloride, 3 mg chlorpheniramine maleate and 15 mg of dextromethorphan hydrobromide. Copyright © 2014 John Wiley & Sons, Ltd.
Keywords:tramadol  dextromethorphan  chlorpheniramine  LC‐MS/MS  plasma
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号