首页 | 本学科首页   官方微博 | 高级检索  
     

面向个人剂量计校准的小尺度伽玛参考辐射模拟研究
引用本文:钱易坤, 冯鹏, 刘易鑫, 等. 面向个人剂量计校准的小尺度伽玛参考辐射模拟研究[J]. 强激光与粒子束, 2021, 33: 046002. doi: 10.11884/HPLPB202133.200280
作者姓名:钱易坤  冯鹏  刘易鑫  朱亚地  黄宇晨  张颂  何鹏  魏彪  毛本将
作者单位:1.中国工程物理研究院 核物理与化学研究所,四川 绵阳 621900;;2.重庆大学 光电工程学院,重庆 400044
基金项目:重庆大学中央高校基本科研业务费资助项目(2018CDGFGD0008);国家自然科学基金青年基金项目(11805111);国防科工局研究课题
摘    要:针对伽玛射线个人剂量计基于标准伽玛参考辐射进行校准时检定效率低、校准工作复杂和需要远程送检的关键技术问题,建构了1 Ci 137Cs放射源小尺度参考辐射场物理模型,采用蒙特卡罗方法,研究了小尺度参考辐射场内的剂量分布、装置结构和待检剂量计变化导致散射射线对剂量场的影响,获得了待检剂量计形状、数量、类型和装置结构产生的散射伽玛射线对小尺度参考辐射量值定度的影响结果。研究结果表明,1 Ci 137Cs可以为小尺度参考辐射辐射场检验点提供1.5 mSv/h的伽玛遂行剂量率,辐照个人剂量计载台直径30 cm束斑上的剂量率相对标准偏差约为0.48%。当载台厚度为20 mm时,散射射线对小尺度参考辐射检验点处剂量率值的影响率为3.27%,高于剂量计尺寸(1.62%)和剂量计数量(0.56%)的影响。

关 键 词:个人剂量计   剂量量值定度   小尺度参考辐射   蒙特卡罗方法   遂行校准
收稿时间:2020-10-11
修稿时间:2021-01-19

Personal dosimeter calibration based on minitype reference radiation
Qian Yikun, Feng Peng, Liu Yixin, et al. Personal dosimeter calibration based on minitype reference radiation[J]. High Power Laser and Particle Beams, 2021, 33: 046002. doi: 10.11884/HPLPB202133.200280
Authors:Qian Yikun  Feng Peng  Liu Yixin  Zhu Yadi  Huang Yuchen  Zhang Song  He Peng  Wei Biao  Mao Benjiang
Affiliation:1. China Academy of Engineering Physics, Mianyang 621900, China;;2. College of Optoelectronics Engineering, Chongqing University, Chongqing 400044, China
Abstract:Gamma-ray personal dosimeters are important tools for the radiation protection for workers. However, the current calibration method based on standard reference radiation has low verification efficiency, large calibration workload, and requires remote inspection. To solve the above problems, this paper attempts to apply the minitype reference radiation to the calibration of gamma-ray personal dosimeters. The Monte Carlo method is used to simulate the dose distribution in the minitype reference radiation field, the influence of scattering rays which are caused by the device structure and dosimeters in the dose field. The results show that 1 Ci 137Cs can provide a dose rate of 1.5 mSv/h for the point of test, and the relative standard deviation of the dose rate at the point of test is about 0.48%. When the thickness of the stage is 20 mm, the influence rate of scattered rays on the dose rate value at the minitype reference radiation inspection point is 3.27%, which is higher than the influence of the size of the dosimeter (1.62%) and the number of dosimeters (0.56%). This paper provides a theoretical basis for in situ calibration to calibrate gamma-ray personal dosimeters.
Keywords:personal dosimeter  dose value calibration  minitype reference radiation  Monte Carlo method  in situ calibration
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《强激光与粒子束》浏览原始摘要信息
点击此处可从《强激光与粒子束》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号