首页 | 本学科首页   官方微博 | 高级检索  
     

超高效合相色谱法快速检测纺织品中的8种荧光增白剂
引用本文:汤娟,丁友超,曹锡忠,齐琰,钱凯. 超高效合相色谱法快速检测纺织品中的8种荧光增白剂[J]. 色谱, 2014, 32(11): 1230-1235. DOI: 10.3724/SP.J.1123.2014.07030
作者姓名:汤娟  丁友超  曹锡忠  齐琰  钱凯
作者单位:江苏出入境检验检疫局工业产品检测中心, 江苏 南京 210001
基金项目:国家质检总局科技计划项目(2013IK108).
摘    要:建立了同时检测纺织品中1,2-双(5-甲基-2-苯并恶唑基)-乙烯(PF)、7-二乙氨基-4-甲基香豆素(SWN)、2,2'-(2,5-二苯基硫代)双[5-(1,1-二甲基乙基)]苯并恶唑(OB)、2-[4-[2-[4-(2-苯并恶唑基)苯基]乙烯基]苯基]-5-甲基苯并恶唑(KSN)、1,4-双(2-氰基苯乙烯基)苯(ER-Ⅰ)、1-邻氰苯乙烯基-4-对氰苯乙烯基苯(ER-Ⅱ)、2,2-(1,4-亚萘基)双(苯并恶唑)(KCB)和4,4'-双[2-(2-甲氧基苯基)亚乙基]-1,1'-联苯(FP)8种荧光增白剂的超高效合相色谱(UPC2)检测方法。样品经二甲苯提取、浓缩、定容后,由UPC2进行定性定量分析。以超临界CO2-甲醇为流动相,梯度洗脱,采用ACQUITY UPC2 HSS C18 SB色谱柱(100 mm×3.0 mm,1.8 μm)进行分离。8种荧光增白剂在1.0~20.0 mg/L范围内线性良好(r≥0.9991),定量限(LOQ,S/N=10)在0.70~0.95 mg/L之间。不同添加水平的回收率范围为90.9%~96.5%,相对标准偏差(RSD)为2.8%~4.2%。该方法简单、准确度高、分析时间短,可用于快速检测纺织品中的8种荧光增白剂。

关 键 词:超高效合相色谱  纺织品  荧光增白剂  
收稿时间:2014-07-18

Rapid detection of eight fluorescent whitening agents in textile by ultra performance convergence chromatography
TANG Juan,DING Youchao,CAO Xizhong,QI Yan,QIAN Kai. Rapid detection of eight fluorescent whitening agents in textile by ultra performance convergence chromatography[J]. Chinese journal of chromatography, 2014, 32(11): 1230-1235. DOI: 10.3724/SP.J.1123.2014.07030
Authors:TANG Juan  DING Youchao  CAO Xizhong  QI Yan  QIAN Kai
Affiliation:Inspection Center of Industry Products, Jiangsu Entry-Exit Inspection and Quarantine Bureau, Nanjing 210001, China
Abstract:An accurate quantitative and confirmative method has been developed for the determination of eight fluorescent whitening agents (FWAs) in textile by ultra performance convergence chromatography (UPC2) coupled with photo diode array (PDA) detection, including 1,2-bis(5-methyl-2-benzoxazole)ethylene (PF), 7-diethylamino-4-methylcoumarin (SWN), 2,2'-(2,5-thiophenediyl)bis(5-(1,1-dimethylethyl)-benzoxazol (OB), 2-[4-[2-[4-(2-benzoxazolyl) phenyl]ethenyl]phenyl]-5-methyl-benzoxazol (KSN), 1,4-bis(2-cyanostyryl)benzene (ER-Ⅰ), 1-(2-cyanostyryl)-4-(4-cyanostyryl)benzene (ER-Ⅱ), 2,2'-(1,4-naphthalenediyl)bis-benzoxazol (KCB), 4,4'-bis[2-(2-methoxyphenyl)ethenyl]-1,1'-biphenyl (FP). The sample was extracted with xylene and concentrated by a rotary evaporator, and then qualitatively and quantitatively analyzed by UPC2. The separation of target compounds was achieved on an ACQUITY UPC2 HSS C18 SB column (100 mm×3.0 mm, 1.8 μm) by a gradient elution with supercritical carbon dioxide and methanol as mobile phases. External standard method was used for the quantitative determination and the calibration curves showed good linearity in the concentration range of 1.0-20.0 mg/L for the eight target compounds with correlation coefficients not less than 0.9991. The limits of quantification of the eight compounds (LOQs, S/N=10) were 0.70-0.95 mg/L. The average recoveries of the eight compounds ranged from 90.9% to 96.5% at the spiked levels of 2.0, 5.0, 10.0 mg/kg with the relative standard deviations (RSDs) of 2.8%-4.2%. The method is simple, accurate and time-saving with high sensitivity, and can be used for the rapid determination of the eight FWAs in textile.
Keywords:ultra performance convergence chromatography(UPC 2)  fluorescent whitening agents(FWAs)  textile
本文献已被 CNKI 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号