首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Recombinant cell bioassay systems for the detection and relative quantitation of halogenated dioxins and related chemicals
Authors:Denison Michael S  Zhao Bin  Baston David S  Clark George C  Murata Hiroshi  Han Dalho
Institution:

a Department of Environmental Toxicology, University of California, Meyer Hall, One Shields Avenue, DavisCA 95616-8588, USA

b Xenobiotic Detection Systems, Inc., 1601 E. Geer Street, Suite S., Durham NC 27704, USA

c Hiyoshi Corporation, 908 Kitanoshocho, Omihachiman, Shiga, Japan

Abstract:Proper epidemiological, risk assessment and exposure analysis of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD, dioxin) and related halogenated aromatic hydrocarbons (HAHs) requires accurate measurements of these chemicals both in the species of interest and in various exposure matrices (i.e. biological, environmental, food and feed). High-resolution instrumental analysis techniques are established for these chemicals, however, these procedures are very costly and time-consuming and as such, they are impractical for large scale sampling studies (i.e. for epidemiological studies and assessment of areas with widespread contamination). Accordingly, numerous bioanalytical methods have been developed for the detection of these chemicals in extracts from a variety of matrices, the majority of which take advantage of the ability of these chemicals to activate the aromatic hydrocarbon receptor (AhR) and the AhR signal transduction pathway. Here we review the currently available in vitro AhR-based cell bioassay systems with a focus on recent recombinant reporter gene cell lines that have been developed for detection and relative quantitation of TCDD and related HAHs. Comparison of the relative sensitivities of the various cell bioassays and examples of their use in screening and analysis of environmental, biological, and food and feed samples are presented. Currently available experimental results and validation studies demonstrate the utility of these cell bioassay systems to provide a relatively rapid, accurate, and cost effective screening approach for the detection of TCDD and related HAHs in a variety of environmental, biological, food and feed samples. The availability of these cell bioassay systems will not only facilitate the large scale sampling studies needed for accurate assessment of contamination and exposure to these environmental chemicals, but they provide avenues for the identification of novel classes of TCDD-like chemicals.
Keywords:Dioxin  2  3  7  8-Tetrachlorodibenzo-p-dioxin  TCDD  Bioassay  Ah receptor  Luciferase  CALUX
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号