首页 | 本学科首页   官方微博 | 高级检索  
     检索      


High-performance liquid chromatographic assay of fleroxacin in human serum using fluorescence detection
Authors:Djurdjevic P  Jelikic-Stankov M  Laban A
Institution:Faculty of Science, P.O. Box 60, 34000 Kragujevac, Yugoslavia.
Abstract:A HPLC method has been developed for the direct assay of fleroxacin in serum, without previous extraction. Serum samples, after the addition of sodium dodecylsulfate (0.5%), were injected directly into an LC Hisep column. The mobile phase consisted of acetonitrile, water and triethylamine in a per cent volume ratio 18:80:2. The pH of the mobile phase was adjusted to 6.50 with the addition of phosphoric acid. The drug was detected fluorometrically at lambda (ex )=280 nm and lambda (em )=450 nm . The linear concentration range of fleroxacin was between 0.01 and 2.0mg/l with a detection limit of 1ng/ml.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号