摘    要:A sensitive and selective electrochemical sensor for the determination of glutathione(GSH) was developed using a modified multiwall carbon nanotube paste electrode with 3,4 dihydroxy cinnamic acid as a mediator.This modified electrode showed very high electrocatalytic activity for the anodic oxidation of GSH.Under the optimized conditions,the electrocatalytic peak current showed a linear relationship with GSH concentration in the range of 0.5-400.0 μmol/L with a detection limit of 0.1 μmol/L GSH.The relative standard deviations for seven successive assays of 5.0 and 25.0 μmol/L GSH were 2.2% and 2.7%,respectively.The modified electrode was used for the determination of GSH compounds in real urine samples.

关 键 词:Glutathione  3  4-Dihydroxy-cinnamic  acid  Carbon  paste  electrode  Multiwall  carbon  nanotube  Sensor
收稿时间:2013-05-10

Multiwall carbon nanotube paste electrode with 3,4-dihydroxy-cinnamic acid as mediator for the determination of glutathione in pharmaceutical and urine samples
Mohsen Keyvanfard,Hassan Karimi-Maleh,Khadijeh Alizad.Multiwall carbon nanotube paste electrode with 3,4-dihydroxy-cinnamic acid as mediator for the determination of glutathione in pharmaceutical and urine samples[J].Chinese Journal of Catalysis,2013,34(10):1883-1889.
Authors:Mohsen Keyvanfard  Hassan Karimi-Maleh  Khadijeh Alizad
Institution:a Department of Chemistry, Majlesi Branch, Islamic Azad University, Isfahan, Iran;
b Department of Chemistry, Graduate University of Advanced Technology, Kerman, Iran
Abstract:A sensitive and selective electrochemical sensor for the determination of glutathione (GSH) was developed using a modified multiwall carbon nanotube paste electrode with 3,4-dihydroxy-cinnamic acid as a mediator. This modified electrode showed very high electrocatalytic activity for the anodic oxidation of GSH. Under the optimized conditions, the electrocatalytic peak current showed a linear relationship with GSH concentration in the range of 0.5-400.0 μmol/L with a detection limit of 0.1 μmol/L GSH. The relative standard deviations for seven successive assays of 5.0 and 25.0 μmol/L GSH were 2.2% and 2.7%, respectively. The modified electrode was used for the determination of GSH compounds in real urine samples.