Sensitive Voltammetric Determination of Captopril Using a Carbon Paste Electrode Modified with Nano-TiO2/Ferrocene Carboxylic Acid
Authors:Jahan Bakhsh RAOOF  Reza OJANI  Mehdi BAGHAYERI
Institution:Electroanalytical Chemistry Research Laboratory, Department of Analytical Chemistry, Faculty of Chemistry,Mazandaran University, Babolsar 47416-95447, Iran
Abstract:A carbon paste electrode (CPE) modified with ferrocene carboxylic acid (FcCA) and TiO2 nanoparticles was constructed by incorporating TiO2 nanoparticles and ferrocene carboxylic acid into the carbon paste matrix.The electrochemical behavior of captopril (CAP) at the surface of the modified electrode was investigated using electroanalytical methods.The modified electrode showed excellent electrocatalytic activity for the oxidation of CAP in aqueous solutions at physiological pH values.Cyclic voltammetric curves showed that the oxidation of CAP at the surface of the modified electrode reduced its overpotential by more than 290 mV.The modified electrode was used for detecting captopril using cyclic voltammetry and square wave voltammetry techniques.A calibration curve in the range of 0.03 to 2400μmol/L was obtained that had a detection limit of 0.0096 μmol/L (3σ) under the optimized conditions.The modified electrode was successfully used for the determination of captopril in pharmaceutical and biological samples.
Keywords:electrocatalysis  modified electrode  nano-TiO2  ferrocene carboxylic acid captopril  cyclic voltammetry