Validation and clinical application of an LC‐ESI‐MS/MS method for simultaneous determination of tolmetin and MED5, the metabolites of amtolmetin guacil in human plasma
Authors:Kishore Kumar Hotha  D Vijaya Bharathi  S Sirish Kumar  Y Narsimha Reddy  Pankaj Chatki  L K Ravindranath  K N Jaya Veera  Ramesh Mullangi
Institution:1. Bioanalytical Department, Integrated Product Development, Dr Reddy's Laboratories Ltd, Bachupalli, Hyderabad‐500 072, India;2. Department of Chemistry, JNT University, Anantapur, Andhra Pradesh‐515 001, India;3. Department of Chemistry, S.K. University, Anantapur‐515 001, A.P, India
Abstract:A highly sensitive, rapid assay method has been developed and validated for the simultaneous estimation of tolmetin (TMT) and MED5 in human plasma with liquid chromatography coupled to tandem mass spectrometry with electrospray ionization in the positive‐ion mode. A simple solid‐phase extraction process was used to extract TMT and MED5 along with mycophenolic acid (internal standard, IS) from human plasma. Chromatographic separation was achieved with 0.2% formic acid–acetonitrile (25:75, v/v) at a flow rate of 0.50 mL/min on an X‐Terra RP18 column with a total run time of 2.5 min. The MS/MS ion transitions monitored were 258.1 → 119.0 for TMT, 315.1 → 119.0 for MED5 and 321.2 → 207.0 for IS. Method validation and clinical sample analysis were performed as per FDA guidelines and the results met the acceptance criteria. The lower limit of quantitation achieved was 20 ng/mL and the linearity was observed from 20 to 2000 ng/mL, for both the anlaytes. The intra‐day and inter‐day precisions were in the range 3.27–4.50 and 5.32–8.18%, respectively for TMT and 4.27–5.68 and 5.32–8.85%, respectively for MED5. This novel method has been applied to a clinical pharmacokinetic study. Copyright © 2010 John Wiley & Sons, Ltd.
Keywords:tolmetin  MED5  LC‐MS/MS  method validation  human plasma  pharmacokinetics
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号