Optimization of throughput in preparative column luquid chromatography by column overloading and partial fractionation of the effluent
Authors:F Eisenbeiß  S Ehlerding  A Wehrli  J F K Huber
Institution:(1) E. Merck, Reagent Division, R+D Chromatography, D-6100 Darmstadt, FRG;(2) Pharmaceutical Department, Sandoz Ltd., Basle, Switzerland;(3) Institute of Analytical Chemistry, University of Vienna, Vienna, Austria
Abstract:Summary The criteria for the optimization of preparative chromatography are sample throughput and product purity. It is shown for column liquid chromatography that the throughput has been maximized for a given purity by column overloading and appropriate fractionation. The size and position of the fraction must be determined by chemical analysis, since overlapping peaks under overloading conditions are usually distorted compared to the peaks of the same amounts of pure compounds. With overloading of the column larger particles can be used as column packings without reduction of the separation effect.
Keywords:Preparative column liquid chromatography  Optimization of throughput  Column overloading  Adjustment of fraction collection
本文献已被 SpringerLink 等数据库收录!