Novel Process Applications Using PHI-TEC II Adiabatic Calorimeter |
| |
Authors: | Singh J |
| |
Institution: | (1) Hazard Evaluation Laboratory Ltd, 50 Moxon Street, Barnet, Herts, EN5 5TS, UK |
| |
Abstract: | This paper presents several applications of the PHI-TEC II that are not commonly associated with adiabatic calorimeters but which have proved to be extremely valuable. These include simulation of a deep oil well for enhanced oil recovery, isothermal calorimetry of a semibatch reaction, catalyst research using flow through reactors (both plug flow and CSTR) with controlled feeds of high pressure liquid and gas.This revised version was published online in November 2005 with corrections to the Cover Date. |
| |
Keywords: | adiabatic calorimeter calorimetry exothermic hazards phi-factor reaction runaway vents |