首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Defect concentration in Ti-substituted YIG from TG curves
Authors:A González Arias  C Torres  C de Francisco  J M Muñoz  P Hernández Gómez  O Alejos  O Montero  J I Iñiguez
Institution:(1) Departamento Física Aplicada, Universidad de La Habana, Cuba;(2) Departamento Electricidad y Electrónica, Universidad de Valladolid, Spain;(3) Departamento Física Aplicada, Universidad de Salamanca, Spain
Abstract:The article discusses theory and experiment about the measurement of defect concentration in Ti-substituted yttrium iron garnet by means of thermogravimetry techniques. The two possible cases arising from oxygen interchange with atmosphere, oxygen vacancies and interstitial cations, may be analyzed quantitatively from the derived expressions. The possibility of another type of defects being present in the samples, not associated to oxygen evolution, is not excluded. Measurements were carried out in air and CO2 for different Ti contents. The substitution tends to increase slightly the defect parameter θ in YIG, while a CO2 reducing atmosphere is much more effective than the Ti substitution for increasing θ. Calculations for a given single-phased sample sintered in air show two possibilities: a deficit of one oxygen atom for every 2.5 unit cells of 96 atoms, or one excess cation for every 3.5 cells. Other samples show very similar results. The accuracy involved in the measurements is about 2–3%.
Keywords:garnets  lattice defects  thermogravimetry
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏