Evaluation of different nucleic acid stains for sensitive double-stranded DNA analysis with capillary electrophoretic separation |
| |
Authors: | Yan Xiaomei Hang Wei Majidi Vahid Marrone Babetta L Yoshida Thomas M |
| |
Institution: | Bioscience Division, Los Alamos National Laboratory, NM 87545, USA. |
| |
Abstract: | This paper outlines the first use of SYTOX Orange, SYTO 82 and SYTO 25 nucleic acid stains for on-column staining of double-stranded DNA (dsDNA) fragments separated by capillary electrophoresis (CE). Low-viscosity, replaceable poly(vinylpyrrolidone) (PVP) polymer solution was used as the sieving matrix on an uncoated fused-silica capillary. The effects of PVP concentration, electric field strength, and incorporated nucleic acid stain concentrations on separation efficiency were examined for a wide range of DNA fragment sizes. Our study was focused on using nucleic acid stains efficiently excitable at a wavelength of 532 nm. Among the five tested nucleic acid stains, SYTOX Orange stain was shown to have the best sensitivity for dsDNA detection by CE. About a 500-fold lower detection limit was obtained compared to commonly used ethidium bromide and propidium iodide. SYTOX Orange stain also provided a wide linear dynamic range for direct DNA quantitation with on-line CE detection. Use of SYTOX Orange stain can greatly improve the measurement of DNA fragments by CE, which will enable an expanded set of applications in genomics and diagnostics. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|