首页 | 本学科首页   官方微博 | 高级检索  
     检索      

气相色谱-脉冲火焰光度法测定水产品中的二硫氰基甲烷残留
引用本文:杨秋红,杨移斌,胥宁,刘永涛,董靖,艾晓辉.气相色谱-脉冲火焰光度法测定水产品中的二硫氰基甲烷残留[J].色谱,2017,35(8):881-885.
作者姓名:杨秋红  杨移斌  胥宁  刘永涛  董靖  艾晓辉
作者单位:中国水产科学研究院长江水产研究所, 农业部水产品质量安全控制重点实验室, 湖北 武汉 430223
基金项目:公益性行业(农业)科研专项任务(201503108-CC-1).
摘    要:建立了气相色谱-脉冲火焰光度法(GC-PFPD)测定水产品中二硫氰基甲烷(MBT)残留的分析方法。用二氯甲烷-正己烷溶液(1∶1,v/v)在超声条件下提取水产品中的MBT,然后用中性氧化铝固相萃取小柱对提取物进行净化和富集,通过HP-5MS石英毛细管柱(30 m×0.32 mm×0.25μm)分离,最后采用配有脉冲火焰光度检测器的气相色谱仪进行测定,外标法定量。MBT在1.0~20.0 mg/L范围内线性关系良好,相关系数为0.997 1;检出限为0.1 mg/kg;加标回收率为65.6%~97.6%,精密度为6.32%~12.8%(n=7)。该法能很好地满足水产品中药物残留检测的需求。

关 键 词:气相色谱法  脉冲火焰光度检测器  固相萃取  二硫氰基甲烷  水产品
收稿时间:2017-04-16

Determination of methylene bisthiocyanate in aquatic products by gas chromatography with pulsed-flame photometric detector
YANG Qiuhong,YANG Yibin,XU Ning,LIU Yongtao,DONG Jing,AI Xiaohui.Determination of methylene bisthiocyanate in aquatic products by gas chromatography with pulsed-flame photometric detector[J].Chinese Journal of Chromatography,2017,35(8):881-885.
Authors:YANG Qiuhong  YANG Yibin  XU Ning  LIU Yongtao  DONG Jing  AI Xiaohui
Institution:Yangtze River Fisheries Research Institute, Chinese Academy of Fishery Sciences, Key Laboratory of Control of Quality and Safety for Aquatic Products, Ministry of Agriculture, Wuhan 430223, China
Abstract:A novel method was developed for the determination of methylene bisthiocyanate (MBT) in aquatic products by gas chromatography with pulsed-flame photometric detector (GC-PFPD). The samples were extracted by dichloromethane-n-hexane (1:1, v/v), concentrated and cleaned up by neutral-alumina SPE cartridges. The extracts were eluted with 8 mL dichloromethane, and blown to dryness by nitrogen at 35℃. The final extracts were redissolved with a mixture of dichloromethane-n-hexane (1:1, v/v), separated by an HP-5MS quartz capillary column (30 m×0.32 mm×0.25 μ m) and detected by PFPD with external standard method. Under the optimum experimental conditions, the standard curve was linear in the range of 1.0-20.0 mg/L with correlation coefficient of 0.9971. The limit of detection was 0.1 mg/kg. Recoveries ranged from 65.6% to 97.6% with RSDs of 6.32%-12.8% (n=7). The method has good innovative, advanced and practical values.
Keywords:gas chromatography (GC)  pulsed-flame photometric detector (PFPD)  solid phase extraction (SPE)  methylene bisthiocyanate (MBT)  aquatic products
本文献已被 CNKI 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号