首页 | 本学科首页   官方微博 | 高级检索  
     检索      

生物样品二恶英分析中两个常见干扰峰的鉴定
引用本文:任代卫,梁韬,黎刚,张海东,王璞,肖珂,李英明,张庆华.生物样品二恶英分析中两个常见干扰峰的鉴定[J].色谱,2014,32(9):971-974.
作者姓名:任代卫  梁韬  黎刚  张海东  王璞  肖珂  李英明  张庆华
作者单位:1. 中国科学院生态环境研究中心, 环境化学与生态毒理学国家重点实验室, 北京 100085;
2. 台州市路桥污水处理有限公司, 浙江 台州 318050
摘    要:利用高分辨气相色谱/高分辨质谱联用仪(HRGC/HRMS)和高分辨气相色谱/低分辨质谱仪(HRGC/LRMS)对实际生物样品中二恶英(polychlorinated dibenzo-p-dioxins and dibenzofurans,PCDD/Fs)的分析过程中13 C标记的2,3,7,8-四氯代二苯并呋喃(13 C12-2,3,7,8-TCDF)监测碎片离子通道的两个常见干扰峰进行了分析鉴定。通过实际样品分析结果首先推测这两个干扰峰可能为有机氯农药类化合物滴滴涕(DDT)降解产物滴滴伊(DDE)的两个异构体,其次采用DDE的标准溶液(包括o,p′-DDE和p,p′-DDE)进行分析确认。通过HRGC/HRMS的色谱峰分离效果分析、色谱保留时间匹配以及与DDE碎片离子的理论丰度比进行比较,最终确认实际样品分析中的两个干扰峰依次为o,p′-DDE和p,p′-DDE。本文可为生物样品中二恶英的准确识别提供重要参考。

关 键 词:高分辨气相色谱/高分辨质谱  高分辨气相色谱/低分辨质谱  干扰物  滴滴伊(DDE)  生物样品  二恶英
收稿时间:2014-05-22

Identification of two interference peaks during dioxin analysis for biological samples
REN Daiwei,LIANG Tao,LI Gang,ZHANG Haidong,WANG Pu,XIAO Ke,LI Yingming,ZHANG Qinghua.Identification of two interference peaks during dioxin analysis for biological samples[J].Chinese Journal of Chromatography,2014,32(9):971-974.
Authors:REN Daiwei  LIANG Tao  LI Gang  ZHANG Haidong  WANG Pu  XIAO Ke  LI Yingming  ZHANG Qinghua
Institution:1. State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China;
2. Taizhou Luqiao Sewage Treatment Corporation, Taizhou 318050, China
Abstract:Two interference peaks which generally appeared in company with 13C labeled 2,3,7,8-tetrachlorodibenzofuran (13C12-2,3,7,8-TCDF) in the same ion channel during dioxin analysis for biological samples were identified using high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) and high resolution gas chromatography/low resolution mass spectrometry (HRGC/LRMS). It was firstly inferred that the interference peaks should be the two isomers of dichlorodiphenyldichloroethylene (DDE), which was a breakdown product of dichlorodiphenyltrichloroethane (DDT), one of the typical organic chlorine pesticides (OCPs). Thereafter, the standard solution of DDE including o,p''-DDE and p,p''-DDE was analyzed for confirmation. By evaluation of the peak separation in HRGC/HRMS, comparison of the GC retention times and ion abundance ratios of the two interference peaks in real samples with the two DDE isomers in standard solution, the interference peaks were finally confirmed as o,p''-DDE and p,p''-DDE in sequence on a DB-5MS column. This study provided valuable information for accurate identification of dioxin compounds during the biological sample analysis.
Keywords:high resolution gas chromatography/high resolution mass spectrometry (HRGC/ HRMS)  high resolution gas chromatography/low resolution mass spectrometry (HRGC/LRMS)  interferences  dichlorodiphenyldichloroethylene (DDE)  biological samples  polychlorinated diben
本文献已被 CNKI 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号