首页 | 本学科首页   官方微博 | 高级检索  
     检索      

固相萃取-离子交换色谱法测定浓缩苹果汁中残留的苯菌灵、多菌灵、噻菌灵
引用本文:何强,孔祥虹,赵洁,李建华,乐爱山,张莹.固相萃取-离子交换色谱法测定浓缩苹果汁中残留的苯菌灵、多菌灵、噻菌灵[J].色谱,2008,26(5):563-567.
作者姓名:何强  孔祥虹  赵洁  李建华  乐爱山  张莹
作者单位:1.Shaanxi Entry-Exit Inspection and Quarantine Bureau, Xi’an 710068, China; 2.College of Science, Xi’an University of Technology, Xi’an 710054, China
基金项目:国家质量监督检验检疫总局课题(No. 2007IK166)
摘    要:建立固相萃取-离子交换色谱法测定浓缩苹果汁中苯菌灵、多菌灵和噻菌灵的残留量。样品直接用水稀释后,于80 ℃下将苯菌灵完全转化为多菌灵,再经SCX固相萃取柱富集,采用LC-SCX离子交换色谱柱(25 cm×4.6 mm,5 μm)分离,二极管阵列检测器检测,以0.1 mol/L KH2PO4溶液(pH 2.5)-乙腈(体积比为70 ∶30)为流动相,在1.0 mL/min下等度洗脱,于282 nm波长下检测。在0.02~2.0 mg/L范围内,多菌灵和噻菌灵的峰面积与其浓度呈良好的线性关系,最低检出限均可达到0.004 mg/kg,回收率为94.2%~100.4%,相对标准偏差低于4.2%。该方法简便、快速、灵敏、准确,可用于浓缩苹果汁中苯菌灵、多菌灵和噻菌灵残留量的检测。

关 键 词:苯菌灵  多菌灵  固相萃取  离子交换色谱  浓缩苹果汁  噻菌灵  
收稿时间:2008-10-27
修稿时间:2008-10-27

Determination of benomyl,carbendazim and thiabendazole in apple juice concentrate using solid-phase extraction coupled with ion exchange chromatography
HE Qiang,KONG Xianghong,ZHAO Jie,LI Jianhua,YUE Aishan,ZHANG Ying.Determination of benomyl,carbendazim and thiabendazole in apple juice concentrate using solid-phase extraction coupled with ion exchange chromatography[J].Chinese Journal of Chromatography,2008,26(5):563-567.
Authors:HE Qiang  KONG Xianghong  ZHAO Jie  LI Jianhua  YUE Aishan  ZHANG Ying
Institution:1.Shaanxi Entry-Exit Inspection and Quarantine Bureau, Xi’an 710068, China; 2.College of Science, Xi’an University of Technology, Xi’an 710054, China
Abstract:A method was developed for the determination of benomyl, carbendazim and thiabendazole in apple juice concentrate by solid-phase extraction coupled with ion exchange chromatography (IEC). The sample was diluted with water, and then benomyl was degradated completely to carbendazim at 80 ℃, and purified by an SCX solid-phase extraction column. Liquid chromatographic analysis was performed on the instrument of Agilent 1200 series equipped with a diode-array detector and autosampler. The column was LC-SCX (25 cm×4.6 mm, 5 μm). The mobile phase was 0.1 mol/L KH2PO4 (pH 2.5)-acetonitrile (70∶30, v/v) with a flow rate of 1.0 mL/min. The presented method showed good linear relationship with good precision and accuracy at the range of 0.02-2.0 mg/L for carbendazim and hiabendazole. The detection limits were 0.004 mg/kg for carbendazim and thiabendazole. The method was characterized with cceptable sensitivity to meet the requirements for monitoring these pesticides in apple juice concentrate.
Keywords:solid-phase extraction (SPE)  ion exchange chromatography (IEC)  benomyl  carbendazim  thiabendazole  apple juice concentrate
本文献已被 维普 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号