首页 | 本学科首页   官方微博 | 高级检索  
     检索      

反气相色谱法测定Kovats及Flory-Huggins保留参数的变化以探究润滑油的氧化机理
作者姓名:MOSTAFA Nagy E  EISSA Elham A
作者单位:Egyptian Petroleum Research Institute, Cairo, Egypt
摘    要: Inverse gas chromatographic technique (IGC) was attempted as a new approach to follow the chemical changes that occur during lubricating base oil oxidation. Three groups of the oxidized base oils were prepared at different oxygen flow rates, periods and temperatures according to IP48 method. The corrected retention volumes (VR) were calculated for a series of selected test solutes possessing different functional groups on the oxidized base oils used as stationary phases. Kovats retention index (I), Flory-Huggins interaction parameter (κ∞1,2), and partial molar free energy of solution (ΔG∞L), were calculated for the given test solutes from their VR. The relationships between the I values and the oxidation variables were plotted and discussed. The obtained results were confirmed by potentiometric titration. The study reveals that the magnitudes of variation of I, κ∞1,2 or ΔG∞L retention parameters depend on the oxidation degree of the base oil. Large differences between the I values permit discrimination between the different oxidation steps.

关 键 词:Kovatsretentionindex  lubricatingbaseoil  oxidation  inversegaschromatography(IGC)  
文章编号:1000-8713(2006)03-0284-06
收稿时间:2006-02-20
修稿时间:2006年2月20日

Inverse Gas Chromatography Used to Study Lubricating Oil Oxidation Mechanism via Changes in Kovats and Flory-Huggins Retention Parameters
MOSTAFA Nagy E,EISSA Elham A.Inverse Gas Chromatography Used to Study Lubricating Oil Oxidation Mechanism via Changes in Kovats and Flory-Huggins Retention Parameters[J].Chinese Journal of Chromatography,2006,24(3):284-289.
Authors:MOSTAFA Nagy E  EISSA Elham A
Institution:Egyptian Petroleum Research Institute, Cairo, Egypt
Abstract:Inverse gas chromatographic technique (IGC) was attempted as a new approach to follow the chemical changes that occur during lubricating base oil oxidation. Three groups of the oxidized base oils were prepared at different oxygen flow rates, periods and temperatures according to IP48 method. The corrected retention volumes (VR) were calculated for a series of selected test solutes possessing different functional groups on the oxidized base oils used as stationary phases. Kovats retention index (I), Flory-Huggins interaction parameter (κ∞1,2), and partial molar free energy of solution (ΔG∞L), were calculated for the given test solutes from their VR. The relationships between the I values and the oxidation variables were plotted and discussed. The obtained results were confirmed by potentiometric titration. The study reveals that the magnitudes of variation of I, κ∞1,2 or ΔG∞L retention parameters depend on the oxidation degree of the base oil. Large differences between the I values permit discrimination between the different oxidation steps.
Keywords:inverse gas chromatography (IGC)  oxidation  lubricating base oil  Kovats retention index
本文献已被 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文