首页 | 本学科首页   官方微博 | 高级检索  
     检索      

气相色谱-质谱法测定动物组织中三种1,2-二苯乙烯类药物的残留量
引用本文:吴银良,刘素英,侯东军,沈建忠,王海,单吉浩.气相色谱-质谱法测定动物组织中三种1,2-二苯乙烯类药物的残留量[J].色谱,2006,24(5):462-465.
作者姓名:吴银良  刘素英  侯东军  沈建忠  王海  单吉浩
作者单位:1.Quality Control and Inspection Center for Domestic Animal Products of Ministry of Agriculture, Beijing 100026, China; 2.College of Veterinary Medicine, China Agricultural University, Beijing 100094, China
基金项目:科技部技术标准专项基金
摘    要:建立了动物组织中己烯雌酚(DES)、己二烯雌酚(DIS)和己烷雌酚(HS)残留量的气相色谱-质谱分析方法。动物组织样品在碱性条件下用乙酸乙酯提取,经碳酸钠溶液液-液分配净化,再用硅胶柱固相萃取净化,洗脱液均分成两份后经氮气吹干,分别用双三甲基硅基三氟乙酰氨(BSTFA)和七氟丁酸酐(HFBA)衍生,采用选择离子监测模式(SIM)进行测定,外标法定量。检出限为0.30 μg/kg(cis-DES),0.10 μg/kg(trans-DES和HS)和0.15 μg/kg(DIS)。在0.5~4.0 μg/kg添加水平,回收率为73.0%~86.5%,相对标准偏差(RSD)为1.0%~7.2%。衍生物的峰面积与样品浓度在10~1000 μg/L(DES和DIS) 和5~500 μg/L(HS)范围内呈良好的线性关系,线性回归系数大于0.99。

关 键 词:固相萃取  气相色谱  质谱  1  2-二苯乙烯类药物  残留  动物组织
文章编号:1000-8713(2006)05-0462-04
收稿时间:2005-11-30
修稿时间:2005年11月30

Determination of Residues of Three Stilbene Drugs in Animal Tissues Using Gas Chromatography-Mass Spectrometry
WU Yinliang,LIU Suying,HOU Dongjun,SHEN Jianzhong,WANG Hai,SHAN Jihao.Determination of Residues of Three Stilbene Drugs in Animal Tissues Using Gas Chromatography-Mass Spectrometry[J].Chinese Journal of Chromatography,2006,24(5):462-465.
Authors:WU Yinliang  LIU Suying  HOU Dongjun  SHEN Jianzhong  WANG Hai  SHAN Jihao
Institution:1.Quality Control and Inspection Center for Domestic Animal Products of Ministry of Agriculture, Beijing 100026, China; 2.College of Veterinary Medicine, China Agricultural University, Beijing 100094, China
Abstract:A method has been developed to determine residual stilbenes such as diethylstilbestrol (DES), dienestrol (DIS) and hexestrol (HS) in animal tissues using solid phase extraction (SPE) and gas chromatography-mass spectrometry (GC-MS). The procedures for extraction, cleanup on an LC-Si solid phase extraction cartridge and derivatization of stilbenes were established and optimized. The analytes were detected by mass spectrometer with electron impact source in selected ion monitoring mode (EI/SIM), and quantified with an external standard calibration curve method. Linear calibration curves were obtained in the concentration ranges from 5 to 500 microg/L for HS and from 10 to 1000 microg/L for DES and DIS (the correlation coefficients were above 0.99). Recoveries of the stilbenes were 73.0%-86.5%, and the relative standard deviations were between 1.0% and 7.2%. The limits of detection were 0.30 microg/kg for cis-DES, 0.10 microg/kg for trans-DES and HS and 0.15 microg/kg for DIS in pork and swine liver.
Keywords:solid phase extraction(SPE)  gas chromatography(GC)  mass spectrometry(MS)  stilbenes  residue  animal tissues
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《色谱》浏览原始摘要信息
点击此处可从《色谱》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号