首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于次血红素六肽的过氧化氢和葡萄糖灵敏比色方法
引用本文:石鑫,刘传志,宫平,李伟,侯玥.基于次血红素六肽的过氧化氢和葡萄糖灵敏比色方法[J].应用化学,2019,36(7):847-854.
作者姓名:石鑫  刘传志  宫平  李伟  侯玥
作者单位:长春理工大学生命科学技术学院 长春 130022
基金项目:吉林省科技厅科技攻关计划(20170204029SF)资助
摘    要:采用次血红素六肽(DhHP-6)催化H2O2氧化4-氨基安替吡啉-氯代苯酚显色体系,建立了测定H2O2和葡萄糖的方法。 研究了pH值、底物浓度和DhHP-6浓度对实验的影响,检测了比色方法的反应线性、稳定性、相关性和回收率。 在最佳反应条件下,DhHP-6在不同时间及温度条件下,活性要优于过氧化物酶(POD);DhHP-6催化H2O2 的米氏常数(Km)和最大反应速率(vmax)分别为0.171 mmo/L和4.22×10-6 mol/s;H2O2响应的线性范围为0.39~25.0 mmol/L;高、中、低 3水平测定的变异系数(CV)和加标回收率分别在1.29%~2.16%和94.5%~101.1%之间;与葡萄糖商品试剂盒比较相关系数R2=0.9946;36例血液样品中的葡萄糖浓度在4.26~17.48 mmol/L之间。 与葡萄糖检测商品试剂盒之间的两组数据经统计差异不显著(P>0.05)。 该方法是一种简单、廉价、方便、灵敏的比色测定方法。

关 键 词:过氧化氢  次血红素六肽  模拟酶  比色分析  
收稿时间:2019-02-21

Hydrogen Peroxide and Glucose Sensitive Colorimetric Method Based on Deuterohemin-Ala His Thr Val Glu Lys
Xin SHI,Chuanzhi LIU,Ping GONG,wei LI,Yue HOU.Hydrogen Peroxide and Glucose Sensitive Colorimetric Method Based on Deuterohemin-Ala His Thr Val Glu Lys[J].Chinese Journal of Applied Chemistry,2019,36(7):847-854.
Authors:Xin SHI  Chuanzhi LIU  Ping GONG  wei LI  Yue HOU
Institution:School of Life Science and Technology,Changchun University of Science and Technology,Changchun 130022,China
Abstract:A simple colorimetric method for determination of H2O2 and glucose was established based on the peroxidase-like activity of deuterohemin-Ala His Thr Val Glu Lys(DhHP-6) to catalyze the oxidation of 4-aminoantipyrine(4-APP)-chlorophenol color reaction system in the presence of H2O2. The effects of pH, substrate concentration and DhHP-6 concentration were observed, and the reaction linearity, stability, correlation and recovery rate of the colorimetric method were detected. Under optimal reaction conditions, the activity of DhHP-6 is superior to that of peroxidase(POD) under different temperatures and times; the Michaelis constant(Km) and maximum reaction rate(vmax) of DhHP-6 catalyzing H2O2 are 0.171 mmol/L and 4.22×10-6 mol/s, respectively; the linearity range of H2O2 response is 0.39~25.0 mmol/L, the coefficient of variation(CV) and spiked recovery of the high, medium and low levels are between 1.29%~2.16% and 94.5%~101.1%, respectively; and correlation coefficient with the commercial kit is 0.9946; the concentration of glucose in 36 blood samples are 4.26~17.48 mmol/L. There is no significant difference between the two sets of data for glucose assay kit(P>0.05). Therefore, this is a simple, cheap, convenient and sensitive colorimetric determination method.
Keywords:hydrogen peroxide  deuterohemin-Ala His Thr Val Glu Lys  mimetic enzyme  colorimetric analysis  
本文献已被 CNKI 等数据库收录!
点击此处可从《应用化学》浏览原始摘要信息
点击此处可从《应用化学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号