火焰原子吸收光谱法测定人发中镁时工作条件对干扰影响的研究
引用本文:张俊浩,李增禧.火焰原子吸收光谱法测定人发中镁时工作条件对干扰影响的研究[J].广东微量元素科学,1997,4(4):23-27.
作者姓名:张俊浩  李增禧
作者单位:[1]广东工业大学 [2]广东省测试分析研究所
摘    要:研究了用HNO3-HClO4湿法消化样品,火焰原子吸收法测定人发中镁时工作条件对干扰的影响,在测量高度为12mm,乙炔流量为1.0L/min时,可以不加释放剂而直接测定镁。标准加入回收率为96% ̄105%,相对标准偏差为3.0%。

关 键 词:人发    火焰原子吸收法  测定  原子光谱

Study on the Effect of Working Conditions on Interference in the Determination of Mg in Human Hair by AAS
Zhang Junhao, Yu Yumian, Peng Lanqiao, Kong Dengming.Study on the Effect of Working Conditions on Interference in the Determination of Mg in Human Hair by AAS[J].Trace Elements Science,1997,4(4):23-27.
Authors:Zhang Junhao  Yu Yumian  Peng Lanqiao  Kong Dengming
Abstract:The effect of werking conditions on interference has been studied during the deterthena-tion of Mg in human hair by atoAnc absorption spectrometry. The samples are digested with HNO3-HClO4. When Burner height is 12 mm and the nowrate of C2H2 is 1. 0L/min, Mg can be deterndned directly without any releaser. The recovery ratio is 96%~105%, the relative standard derivation is 3. 0%.
Keywords:FAAS  Human hair  Magnesium  Interference