Development,validation and application of an HPLC method for phenol electrooxidation products in the presence of chloride
Authors:Linxi Chen
Institution:Department of Biomedical, Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
Abstract:A high-performance liquid chromatography (HPLC) method was developed and validated to determine phenol and potential intermediates from hydroxylation (hydroquinone, benzoquinone, catechol) and hypochlorination (2-chlorophenol, 3-chlorophenol, 4-chlorophenol, 2,4-dichlorophenol, 2,6-dichlorophenol, 2,3,6-trichlorophenol, 2,4,5-trichlorophenol, 2,4,6-trichlorophenol and pentachlorophenol) pathways during electrooxidation in the presence of chloride. A Hypersil ODS column (150 mm L × 4.6 mm I.D.) was used for the separation. The best separation was achieved when using a time variant gradient between a water mobile phase (with 0.1% formic acid adjusted to pH 3.0 with 0.1 mM sulfuric acid) and an organic phase (90:5:5 by volume mixture of acetonitrile:methanol:acetic acid). The flow rate was 0.8 mL min?1 and UV absorbance was monitored at 270, 280, 290 and 300 nm, choosing the wavelength of strongest response for each compound. The intra- and inter-day accuracy and precision were tested using five replicates each day on three consecutive days.
Keywords:electrooxidation  phenol  chloride  HPLC