首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Two-dimensional wall temperature measurements and heat transfer enhancement for top-heated horizontal channels with flow boiling
Authors:Ronald D Boyd  Alvin Smith  Jerry C Turknett
Institution:

Thermal Science Research Center, College of Engineering and Architecture, Prairie View A & M University, Prairie View, Texas, USA

Abstract:Two-dimensional (circumferential and axial) wall temperature distributions were measured for top-heated coolant channels with internal geometries that include smooth walls, spiral fins and both twisted tape and spiral fins. Freon-71 was the working fluid. The flow regimes studied were single-phase, subcooled flow boiling, and stratified flow boiling. The inside diameter of all test sections was near 10.0 mm. Circumferentially averaged heat transfer coefficients at several axial locations were obtained for selected coolant channels for a volumetric flow rate of 4.738 x 10−5m3/s, 0.19 MPa (absolute) exit pressure, and 22.2°C inlet subcooling. Overall (averaged over the entire channel) heat transfer coefficients were compared for the various channel geometries. This comparison showed that the channel with large-pitch spiral fins had higher heat transfer coefficients at all power levels. However, the results appear to indicate that if the twist ratio (ratio of the twisted tape period to the inside diameter) is decreased, the configuration employing both fins and a twisted tape will have had greater enhancements.
Keywords:two-dimensional  wall temperature  single-side heating  flow boiling  heat transfer coefficient  horizontal channel
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号