首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Evaluation of the performance of high-speed PIV compared to standard PIV in a turbulent jet
Authors:M Falchi  G P Romano
Institution:(1) Department of Mechanics and Aeronautics, University “La Sapienza”, Via Eudossiana n° 18, 00184 Rome, Italy
Abstract:In this paper, a comparison between two particle image velocimetry (PIV) systems, one based on a standard cross-correlation charge coupled device (CCD) camera with pulsed laser and another using high-speed complementary metal oxide semiconductor (CMOS) camera with continuous laser is performed. The objective of the paper is to point out advantages and disadvantages of the two systems when computing large and small flow scale statistics. The comparison is performed on velocity measurements in the near and far fields of a circular water jet: on this flow several experimental data and empirical self-similarity laws are available for comparisons. The results show that both systems are suitable for measurements with a preference for the standard one when investigating small-scale statistics. This result depends on the lower number of effectively independent samples acquired by a high-speed system and on the higher noise levels of CMOS sensors in comparison to CCDs.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号