Abstract:The numerical turbulent coalescence/deposition model of Crane and Williams has been used to indicate likely trends in the development of drop size distribution and entrained water flow rate in the cross-over pipes of a nuclear wet steam turbine. Large increases in mean drop diameter have been shown to be possible, the results being very sensitive to the width of the initial size distribution, the entrained wetness fraction and the turbulence intensity. Deposition rate was also found to be strongly dependent on turbulence intensity, but inertial deposition onto and re-entrainment from the turning vanes of a bend did not significantly influence subsequent coalescence and turbulent deposition rates in the single example computed