15万立米气柜残余应力及工作应力测试分析
引用本文:张亦良,徐学东.15万立米气柜残余应力及工作应力测试分析[J].实验力学,1998,13(3):343-348.
作者姓名:张亦良  徐学东
作者单位:北京工业大学
摘    要:报导了15万立米大型煤气气柜挂圈走台的残余应力及气柜升降时工作应力的测试结果。该气柜服役十余年后发生煤气泄漏,为分析其原因,进行了残余应力及气柜修复前后的工作应力测试,结果表明:修复前残余应力及工作应力均达到很高水平,气柜升起时伴有严重侧偏现象,修复后应力状态有明显好转。

关 键 词:煤气气柜,残余应力,工作应力

Stress Measurement for A 150,000 m 3 Gas Vessel
ZHANG Yiliang,XU Xuedong,CHEN Yongmei,ZHOU Jingxue.Stress Measurement for A 150,000 m 3 Gas Vessel[J].Journal of Experimental Mechanics,1998,13(3):343-348.
Authors:ZHANG Yiliang  XU Xuedong  CHEN Yongmei  ZHOU Jingxue
Institution:Beijing Polytechnical University
Abstract:Stress measurement was made for about a ten years old 15,000 m 3 gas vessel to check the reasons of gas leaking. It was found that high level residual stresses existed in the vessel structure, and that during its working (elevating and descending) high working stresses may happen out of the inclination of the moving body. After structure repairing, stress measurement justified that high working stresses were eliminated.
Keywords:residual stress  working stress