首页 | 本学科首页   官方微博 | 高级检索  
     检索      


PIV EXPERIMENTAL STUDY ON THE HEMODYNAMICS OF AORTIC VALVE UNDER VARIED TILTED ANGLES 1)
Authors:Liu Zhaomiao  Xue Hebo  Yang Gang  Pang Yan  Fang Yongchao  Li Mengqi  Qi Yipeng  Shi Yi
Institution:Faculty of Materials and Manufacturing,Beijing University of Technology, Beijing 100124,China;Department of Cardiac Surgery,FuWai Hospital,Chinese Academy of Medical Sciences,Beijing 100037,China
Abstract:Leaflet thrombosis is a typical secondary valvular disease after aortic valve replacement, and abnormal hemodynamic characteristics are crucial in its development. In this study, the effects of angle between the longitudinal axis of the aortic valve and that of the ascending aorta ($\alpha =0^\circ$, $\alpha =5^\circ$, $\alpha =10^\circ$ and $\alpha =15^\circ$) on the velocity, vorticity and viscous shear stress distribution are investigated using particle image velocimetry (PIV). It is of great significance to understand the hemodynamic mechanism of thrombosis after aortic valve replacement. The results show that the transvalvular flow in the aortic root is centrosymmetric flow when $\alpha =0^\circ$, while it tilts to the side of left coronary artery when $\alpha =5^\circ$, $\alpha =10^\circ$ and $\alpha =15^\circ$. The transvalvular flow tilts with the increasing of tilted angle and impacts on the wall of the ascending aorta, damaging the endothelial cells and causing thrombosis. In addition, the velocity within the aortic sinus increases and the vortex also moves toward the bottom of the aortic sinus with aortic valve tilted, which is unfavorable for the blood flowing from the coronary artery ostium to the myocardium for blood supply. Meanwhile, the high vorticity and high viscous shear stress area of the aortic root also tilts to the side of left coronary artery. And the high vorticity area of the aortic sinus is located at the bottom of the aortic sinus and the high viscous shear stress area is distributed at the wall of the aortic sinus. The vorticity and viscous shear stress are realy high when there is a mismatch between the ascending aorta longitudinal axis and that of the aortic valve, especially $\alpha =10^\circ$ and $\alpha =15^\circ$, providing a favorable environment for thrombosis. The results benefit to contribute theoretical bases and technical reference for the selection of clinical aortic valve replacement surgical parameters and that of the avoidance of secondary valvular disease.
Keywords:aortic valve  titled angle  hemodynamics  PIV  
点击此处可从《力学学报》浏览原始摘要信息
点击此处可从《力学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号