Effect of system parameters on the size distributions of hollow nickel microspheres produced by an ultrasound-aided electrical discharge machining process
Authors:Yifan Liu  ;Xianglong Li  ;Fushi Bai  ;Jian Chen  ;Yantao Wang  ;Nan Liu
Institution:[1]School of Manufacturing Science and Engineering, Sichuan University, Chengdu 610065, China; [2]School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney 2052, Australia
Abstract:Ultrasound-aided electric discharge machining(EDM) is an emerging technology for producing hollow nickel microspheres.This technology combines traditional EDM with the cavitation and vibration effects of ultrasound to produce hollow microspheres.In this paper,ultrasound-aided EDM was carried out in a kerosene medium(the working solution).The effects of various parameters on the sizes of microspheres were investigated using scanning electronic microscopy(SEM).Smileview software was used to measure the sizes of the microspheres.Originpro software was used for statistical analysis to determine the size distributions of the microspheres.To study the effects of the system parameters on the sizes of the microspheres,we first investigated the necessity of using an ultrasonic wave with EDM.After comparing the experimental results with and without the ultrasonic field,we found that ultrasound-induced cavitation and vibration effects reduced the diameters of the microspheres.We then studied the effects of several electrical parameters,including the arc current,pulse width,and gap voltage,on the sizes of the microspheres at an ultrasound frequency of 40 kHz.Smaller microspheres could be obtained by lowering the arc current,pulse width,and gap voltage.
Keywords:Hollow microspheres  Ultrasonic-aided EDM  Cavitation  Electrical parameters  Size distribution
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号