首页 | 本学科首页   官方微博 | 高级检索  
     检索      

HL-2A装置MW级中性束加热系统灯丝电源设计与仿真分析
引用本文:成继东,魏会领,余珮炫,曹建勇.HL-2A装置MW级中性束加热系统灯丝电源设计与仿真分析[J].核聚变与等离子体物理,2019,39(3):227-231.
作者姓名:成继东  魏会领  余珮炫  曹建勇
作者单位:核工业西南物理研究院,成都,610041;核工业西南物理研究院,成都,610041;核工业西南物理研究院,成都,610041;核工业西南物理研究院,成都,610041
摘    要:介绍了HL-2A 装置中性束加热系统阴极灯丝电源的主电路拓扑结构、控制硬件及控制时序等。运用MATLAB 仿真软件对灯丝电源主回路进行了反馈控制仿真,发现电流在1000A 左右时,纹波约为1%,而电流降低至200A 时,纹波增大,约为3%。分别去掉低位控制柜内进线端的串联交流滤波电抗器L1 和并联LC 谐波滤波器进行仿真,结果显示输出电流纹波明显变大,说明L1LC 除了能够吸收谐波电流减少进入电网谐波的作用外,还能够对交流调压后的斩波波形进行一定的滤波作用,使得输出波形更加平滑。

关 键 词:中性束加热  离子源  灯丝电源  MATLAB仿真

Design and simulation analysis of filament power supply for MW neutral beam heating system of HL-2A tokamak
CHENG Ji-dong,WEI Hui-ling,YU Pei-xuan,CAO Jian-yong.Design and simulation analysis of filament power supply for MW neutral beam heating system of HL-2A tokamak[J].Nuclear Fusion and Plasma Physics,2019,39(3):227-231.
Authors:CHENG Ji-dong  WEI Hui-ling  YU Pei-xuan  CAO Jian-yong
Institution:(Southwestern Institute of Physics, Chengdu 610041)
Abstract:The main circuit topology, control hardware and control sequence of the cathode filament power supply for the HL-2A neutral beam heating system was introduced. Feedback control simulation of main circuit of filament power supply is carried out through MATLAB simulation software. It is found that the ripple factor is about 1%when the current is about 1000A, and the ripple coefficient increases to 3% when the current drops to 200A. Without the AC filter reactor in series L1 and parallel harmonic filter LC in the low level control cabinet, the output current ripple coefficient becomes larger obviously. It shows that L1 and LC not only absorb harmonic current, but also filter the chopper waveform after AC voltage regulation to make the output waveform smoother.
Keywords:Neutral beam heating  Ion source  Filament power supply  MATLAB simulation  
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《核聚变与等离子体物理》浏览原始摘要信息
点击此处可从《核聚变与等离子体物理》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏